Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Group
Tenant No.
1
1-8
Specifies a tenant number (1-8) to which the Extension Group is
assigned.
(Required if "Tenant Service" is employed.)
•1.3 System Features (F/G)
– Tenant Service
• 2.2 Tenant (P/G)
[Overflow Setting] Destination – Day / Night
Blank
3-4 digits consisting of 0-9
Specifies the destination extension where the call is transferred to
when all extensions in the Extension Group are unavailable or
logged-out in Day / Night mode respectively.
None
[Overflow Setting] Timer
None
None, 5-180 s in 5 s increments
Specifies the length of time in seconds the system is to wait before
transferring the call in the waiting queue to the Overflow
Destination.
(Assignable only when "Operator" is specified in "Group Type"
programming.)
Note
• If "None" is specified, the call is transferred to the Overflow
Destination immediately.
•1.3 System Features (F/G)
– Operator Group
3.3 Extension Group