Panasonic KX-TD500CE Programming Manual
Panasonic KX-TD500CE Programming Manual

Panasonic KX-TD500CE Programming Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD500CE:

Advertisement

Quick Links

DIG
ITAL
SUP
ER
HYB
RID
SYS
TEM
RUN
OFF
LINE
ALA
RM
Digital Super Hybrid System
Programming Guide
KX-TD500CE
Model No.
Please read this manual before connecting the Digital Super Hybrid System.
Thank you for purchasing the Panasonic Model KX-TD500, Digital Super Hybrid System.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic KX-TD500CE

  • Page 1 ITAL LINE Digital Super Hybrid System Programming Guide KX-TD500CE Model No. Please read this manual before connecting the Digital Super Hybrid System. Thank you for purchasing the Panasonic Model KX-TD500, Digital Super Hybrid System.
  • Page 2 Introduction This Programming Guide is designed to serve as a technical reference for the Panasonic Digital Super Hybrid System, KX-TD500. It provides step-by-step instructions for performing system programming using the Maintenance Console software for a PC. About the Other Manuals...
  • Page 3: Table Of Contents

    Table of Contents 1 Configuration ..................5 1.1 Configuration ........................6 1.2 Slot Assignment ......................7 1.3 Trunk Port Assignment....................10 1.4 Extension Port Assignment..................12 1.5 VPS (DPT) Port Assignment ..................17 1.6 E1 Port Assignment ......................22 1.7 DISA Port Assignment ....................25 1.8 BRI Port Assignment ....................26 1.9 PRI Port Assignment....................28 2 System....................
  • Page 4 5.7 Special Carrier Code ....................192 5.8 Absent Message......................193 5.9 DISA / TIE User Code....................195 5.10 VPS Integration ....................... 197 5.11 Caller ID Modification .................... 206 5.12 Caller ID Registration ..................... 209 5.13 UCD Time Table ...................... 211 5.14 Charge........................
  • Page 5: Configuration

    Section 1 Configuration Configuration...
  • Page 6: Configuration

    1.1 Configuration 1.1 Configuration Used to determine the basic system configuration. Configuration...
  • Page 7: Slot Assignment

    1.2 Slot Assignment 1.2 Slot Assignment Assigns the type of service cards, inserted in the free slots in the basic and expansion shelves. Note In some countries, the E1, the E&M and the ELCOT cards must not be connected to the Public Switched Network.
  • Page 8 1.2 Slot Assignment Parameter Card Type Default Blank Value Range Description/Function Specifies the type of service card inserted in the free slots in the basic and expansion shelves. <Selection> None: Not assigned. BRI: ISDN Basic Rate Access Interface card DHLC: Digital Hybrid Line Circuit card DISA: Direct Inward System Access card DLC: Digital Proprietary Line Circuit card DPH: Doorphone Circuit card...
  • Page 9 1.2 Slot Assignment Parameter Status Default — Value Range FAULT Description/Function Used to set the status of the service cards. INS (In-Service): The target service card is operating normally. OUS (Out-of-Service): Programming data for the target service card is entered, but the target service card is not assigned to the system.
  • Page 10: Trunk Port Assignment

    1.3 Trunk Port Assignment 1.3 Trunk Port Assignment Used to assign each trunk port in the system to one of up to 48 trunk groups. Parameter Card No. Default — Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the physical number of the trunk card and its type, which you are going to programme.
  • Page 11 1.3 Trunk Port Assignment Parameter Group No. Default 48: E&M card, 1: Others Value Range 1 - 48 Description/Function Specifies the trunk group (1-48) to which the trunk port is assigned. Notes • Each trunk port must be assigned to a Trunk Group. This programme defines the Trunk Group assignment for each trunk port.
  • Page 12: Extension Port Assignment

    1.4 Extension Port Assignment 1.4 Extension Port Assignment Used to set various parameters for extension ports. XDP extensions are on ports 9 through 16 of a DHLC card. Parameter Card No. Default — Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the physical number of the extension card and its type, which you are going to programme.
  • Page 13 Select this option when you connect a DSS console to the extension port. VPS (DPT) Select this option when a port of Panasonic Voice Processing System (one that supports DPT Integration) is connected to the extension port. Reference •...
  • Page 14 1.4 Extension Port Assignment Parameter Tel. Type Default (Display only) Value Range Please refer to "Description / Function." Description/Function Displays the model number of telephone set which is currently connected to the extension port. <Telephone type list> Unknown: Not connected or Single Line Telephone T7020: APT with SP-PHONE (12-CO) T7030: APT with SP-PHONE, 1-Line Display (12-CO) T7050: APT with MONITOR (12-CO)
  • Page 15 1.4 Extension Port Assignment Parameter Default 1001-: [SP], [NL], [JT], 2001-: [G] Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the DN (Directory Number = extension number) for the extension port. Note • You must assign the paired extension for DN after selecting DSS for the attribute.
  • Page 16 1.4 Extension Port Assignment Parameter Status Default — Value Range FAULT Description/Function Specifies the operating status of the extension port. INS: The extension port is In-Service OUS: The extension port is Out-of-Service. FAULT: The extension port is defective. Reference None Configuration...
  • Page 17: Vps (Dpt) Port Assignment

    1.5 VPS (DPT) Port Assignment 1.5 VPS (DPT) Port Assignment Used to assign parameters for VPS (DPT) ports. Up to eight Panasonic Voice Processing Systems (VPSs) can be connected to the system. How to set up a TVP 1. Assignment of the card which will be connected to the VPS System.
  • Page 18 Parameter TVP No. Default Value Range 1- 8 Description/Function Specifies the device number of a Panasonic Voice Processing System (VPS), which you are going to programme. Reference • 1.3 System Features (F/G) – Integration, VPS • 1.2 Slot Assignment (P/G)
  • Page 19 TVP100 TVP200 TVP200-1 Description/Function Specifies the model number of the Panasonic Voice Processing System which will be connected to the VPS card. Note • Please select "TVP200-1," if HDD (Hard Disc) Software Version of your TVP200 is 2.00 or later.
  • Page 20 1.5 VPS (DPT) Port Assignment Parameter [Ext No.1] DN Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the extension number for B1 channel. Note • This programme allows you to assign an extension number to each Voice Mail port. Since each port connected to the VPS provides two extensions, this enables you to assign extension numbers to each port.
  • Page 21 1.5 VPS (DPT) Port Assignment Parameter [Ext No.2] Group No. Default Blank Value Range 1-128 Description/Function Specifies the Extension Group (1-128) to which the B2 channel of the VPS (DPT) port is assigned. Note • Specifies the extension group number to which the type of extension group, VM or AA, is assigned.
  • Page 22: E1 Port Assignment

    1.6 E1 Port Assignment 1.6 E1 Port Assignment Used to assign parameters for E1 ports. Note • In some countries, the E1 card must not be connected to the Public Switched Network. How to set up an E1 card 1. Insert E1 card into a free slot. Notes •...
  • Page 23 1.6 E1 Port Assignment Parameter Card No. Default — Value Range XXX : E1 [ XXX : Card No. (101-314)] Description/Function Specifies the physical number of the E1 digital trunk card which you are going to programme. Reference • 1.2 Slot Assignment (P/G) Parameter Channel Type Default...
  • Page 24 1.6 E1 Port Assignment Parameter Receiver Type Default Undefined Value Range Undefined Pulse DTMF MFC-R2 Description/Function Specifies the dial type when receiving an incoming call. Undefined: Not assigned. Pulse: DP Signalling sending / receiving DTMF: DTMF Signalling sending / receiving MFC-R2: MFC-R2 Signalling sending / receiving (Digital signalling system-R2 only) Reference...
  • Page 25: Disa Port Assignment

    1.7 DISA Port Assignment 1.7 DISA Port Assignment Used to assign OGM group number for each DISA card. Parameter [Card No.1-8] Location Default (Display only) Value Range 101-314 Description/Function Displays the slot number of the DISA card which you are going to programme.
  • Page 26: Bri Port Assignment

    1.8 BRI Port Assignment 1.8 BRI Port Assignment Used to assign the parameters for BRI (Basic Rate Interface) ports. Parameter Card No. Default — Value Range XXX: BRI [XXX: Card No. (101-314)] Description/Function Specifies the physical number of the BRI card which you are going to programme.
  • Page 27 1.8 BRI Port Assignment Parameter Default Blank Value Range 3-4 digits consisting of 0-9 or X Description/Function Specifies the DN (Directory Number) for the BRI port. (Assignable only when "EXT" is specified in "Type" assignment.) Note • "X" can be used as a wild card character which substitutes any digit in its position.
  • Page 28: Pri Port Assignment

    1.9 PRI Port Assignment 1.9 PRI Port Assignment Used to assign the parameters for PRI (Prime Rate Interface) ports. Parameter Card No. Default — Value Range XXX: PRI30 [XXX: Card No. (101–314)] Description/Function Specifies the physical number of the PRI30 card which you are going to programme.
  • Page 29 1.9 PRI Port Assignment Parameter Group No. Default Value Range 1-48 Description/Function Specifies the Trunk Group (1-48) to which the PRI port is assigned. Reference • 1.3 System Features (F/G) – Trunk Group • 3.2 Trunk Group (P/G) Parameter Status Default —...
  • Page 30 1.9 PRI Port Assignment Configuration...
  • Page 31: System

    Section 2 System System...
  • Page 32: System

    2.1 System 2.1 System Used to assign parameters which affect system-wide operation. System...
  • Page 33: Tenant

    2.2 Tenant 2.2 Tenant Used to assign various parameters on a tenant (1-8) basis. Parameter Tenant No. Default Value Range Description/Function Specifies the tenant number which you are going to programme. Reference • 1.3 System Features (F/G) – Tenant Service Parameter Alert Extension Default...
  • Page 34 2.2 Tenant Parameter DAY / NIGHT Switching Mode Default Manual Value Range Manual Auto Description/Function Specifies the Day / Night switching mode, Manual or Auto. Manual The extension allowed by COS (Class of Service) programming, the Manager or the Operators can switch Day / Night mode at any time desired by dialling the feature number for "Night Mode set / cancel."...
  • Page 35 2.2 Tenant Parameter Day 1 (SUN-SAT) Default 9:00 AM Value Range Disable 12:00-11:59 PM / AM Description/Function Specifies the start time for Day Service 1. Reference • 1.3 System Features (F/G) – Night Service Parameter Night 1 (SUN-SAT) Default 5:00 PM Value Range Same as Day 1 Description/Function...
  • Page 36 2.2 Tenant Parameter Music on Hold Source Default MUS1: [SP], [NL], [G], Tone: [JT] Value Range None MUS1 MUS2 Tone Description/Function Specifies the Music Source port to be used for Music on Hold. Note • If "MUS2" is selected, the actual source depends upon the position of the switch located on the TSW card.
  • Page 37 2.2 Tenant Parameter Automatic Route Selection Default No check Value Range Check [Enable] No check [Disable] Description/Function Specifies whether to utilise ARS (Automatic Route Selection) or not. If set to "No" (No check), "Trunk Access, Idle" is activated instead of ARS when an extension user dials "9" for making an outside call.
  • Page 38 2.2 Tenant Parameter Manager Extension DN Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the extension number for the Manager. Reference • 1.3 System Features (F/G) –Manager Extension • 3 Operator / Manager Operation (U/M) Parameter External Paging Tone Default Check Value Range...
  • Page 39: Numbering Plan

    2.3 Numbering Plan 2.3 Numbering Plan Used to assign the leading digits of extension numbers, and feature numbers for system features. Parameter 1 1st Hundred Block Extension Default 10: [SP], [NL], [JT], 20: [G] Value Range 1-2 digits consisting of 0-9 Description/Function Specifies the leading 1 or 2 digits of the extension number.
  • Page 40 2.3 Numbering Plan Parameter 2 2nd Hundred Block Extension Default 11: [SP], [NL], [JT], 21: [G] Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1. Reference • 1.3 System Features (F/G) – Flexible Numbering Parameter 3 3rd Hundred Block Extension Default 12: [SP], [NL], [JT], 22: [G] Value Range...
  • Page 41 2.3 Numbering Plan Parameter 7 7th Hundred Block Extension Default 21: [SP], [NL], [JT], 31: [G] Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1. Reference • 1.3 System Features (F/G) – Flexible Numbering Parameter 8 8th Hundred Block Extension Default 22: [SP], [NL], [JT], 32: [G] Value Range...
  • Page 42 2.3 Numbering Plan Parameter 11-16 11th Hundred Block Extension - 16th Hundred Block Extension Default Blank Value Range 1-2 digits consisting of 0-9 Description/Function Same as the Parameter 1. Reference • 1.3 System Features (F/G) –Flexible Numbering Parameter 17 Operator Call Default 0: [SP], 9: [NL], [JT], [G] Value Range...
  • Page 43 2.3 Numbering Plan Parameter 20 Speed Dialing - System Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for making a call using a System Speed Dialling number. Reference • 2.2.2 Easy Dialling (U/M) Parameter 21 Speed Dialing - Station Default...
  • Page 44 2.3 Numbering Plan Parameter 25 External Paging Answer / TAFAS Answer Default 42: [SP], [NL], [JT], 44: [G] Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for answering paging announcements through External Pagers or TAFAS (Trunk Answer From Any Station) calls.
  • Page 45 2.3 Numbering Plan Parameter 29 Group Call Pickup Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for answering a call ringing at another extension in the same Extension Group. Reference • 2.3.3 Answering a Call Ringing at Another Telephone (Call Pickup) (U/M) Parameter 30 Directed Call Pickup...
  • Page 46 2.3 Numbering Plan Parameter 33 Hold Retrieve - Trunk Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for retrieving a specific outside call held at another extension. Reference • 2.4.1 Holding a Call (U/M) Parameter 34 Redial Default...
  • Page 47 2.3 Numbering Plan Parameter 38 External Feature Access Default 6: [SP], [NL], [JT], 66: [G] Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for sending a switchhook flash to a host PBX or Centrex system. This is useful when the host PBX offers, for example, "Call Waiting"...
  • Page 48 2.3 Numbering Plan Parameter 42 Call FWD - Do Not Disturb Set / Cancel Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling the Call Forwarding / Do Not Disturb feature. Reference •...
  • Page 49 2.3 Numbering Plan Parameter 46 Executive Busy Override Deny Set / Cancel Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling Executive Busy Override Deny feature. Reference • 2.7.9 Denying Other People the Possibility of Joining Your Conversation (Executive Busy Override Deny) (U/M) Parameter 47 Pickup Dialing Program / Set / Cancel...
  • Page 50 2.3 Numbering Plan Parameter 50 Station Lock Set / Cancel Default 762: [SP], [NL], [JT], 77: [G] Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling Electronic Station Lockout feature. Reference •...
  • Page 51 2.3 Numbering Plan Parameter 54 Live Call Screening Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting / cancelling Live Call Screening feature. Reference • 2.8.3 If a Voice Processing System is Connected (U/M) Parameter 55 Call Log Incoming, Overwrite Mode Default...
  • Page 52 2.3 Numbering Plan Parameter 58 Login / Logout Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for Log-in / Log-out. Reference • 2.5.5 Leaving an Extension Group (Log-In / Log-Out) (U/M) Parameter 59 Automatic Callback Busy Cancel Default Value Range 1-4 digits consisting of 0-9,...
  • Page 53 2.3 Numbering Plan Parameter 62 MCID Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for turning on / off the MCID (Malicious Call Identification) feature. Reference • 2.7.15 Identifying Malicious Callers (Malicious Call Identification [MCID]) (U/M) Parameter 63-70 Quick dial 1 - Quick dial 8...
  • Page 54 2.3 Numbering Plan Parameter 73 Remote FWD Cancel-Once Default Value Range 1-4 digits consisting of 0-9, or # Description/Function With this feature number, the Manager or the Operators can reach an extension that has set Call Forwarding. It is one time ("once") cancellation, not a permanent cancellation of Call Forwarding on the destination.
  • Page 55 2.3 Numbering Plan Parameter 77-92 Other PBX 01 - Other PBX 16 Default Blank Value Range 1-2 digits consisting of 0-9 Description/Function Specifies the leading 1 or 2 digits of the other PBX extension numbers. If you employ PBX code method for TIE calls, this programming is not required.
  • Page 56 2.3 Numbering Plan Parameter 96 CLIP / COLP Default Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for turning on / off the CLIP / COLP (Calling / Connected Line Indentification Presentation) feature. Reference •...
  • Page 57 2.3 Numbering Plan Parameter 100 COS Primary Default 792: [SP], [NL], [JT], 79: [G] Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the feature number for setting the COS Primary. Reference • 3.1.5 Changing Service Level of Extensions (Switching COS) (U/ Parameter 101 COS Secondary Default...
  • Page 58: Class Of Service (Cos)

    2.4 Class of Service (COS) 2.4 Class of Service (COS) Used to assign the Class of Service (COS) parameters. Parameter COS No. Default Value Range 1-96 Description/Function Specifies the COS number which you are going to programme. Reference • 1.3 System Features (F/G) –...
  • Page 59 2.4 Class of Service (COS) Parameter TRS Level – Day / Night Default Value Range Description/Function Specifies the Toll Restriction level (1-8) for each COS number in Day / Night mode respectively. Reference • 1.6 Originating Features (F/G) — Toll Restriction Parameter Time Limit of Outside Calls Default...
  • Page 60 2.4 Class of Service (COS) Parameter Call FWD to CO Default Disable Value Range Enable Disable Description/Function Enables or disables "Call Forwarding to Trunk" feature. Reference • 2.5.1 Forwarding Your Calls (Call Forwarding) (U/M) Parameter Call FWD Follow me Default Enable Value Range Enable...
  • Page 61 2.4 Class of Service (COS) Parameter DND Override Default Disable Value Range Enable Disable Description/Function Enables or disables "DND Override" feature. Reference • 2.2.5 Calling without Restrictions (U/M) Parameter Digits Restriction in CO Talk Mode Default Unrestricted Value Range Unrestricted 1-15: the digits to be dialled out.
  • Page 62 2.4 Class of Service (COS) Parameter Switching Day / Night Mode Default Disable: [SP], [NL], [JT], Enable: [G] Value Range Enable Disable Description/Function Enables or disables switching the Day / Night service on a Class of Service (COS) basis. Reference •...
  • Page 63 2.4 Class of Service (COS) Parameter SDN COS Default Own Extension Value Range Own Extension Description/Function This setting is applied when an extension user makes an outside call using an SDN button on his or her own extension. Own Extension COS (TRS level) of his / her own applies when making an outside call using the SDN button.
  • Page 64 2.4 Class of Service (COS) Parameter Released Link Operation Default Disable Value Range Enable Disable Description/Function Used to turn on / off "Released Link Operation" mode of the extension. When Released Link Operation is enabled, an extension user will be automatically released from a call (extension, outside) after transferring it to the destination, if the destination extension is idle.
  • Page 65 2.4 Class of Service (COS) Parameter ISDN CFU / CFB / CFNR Default Disable Value Range Enable Disable Description/Function Enables or disables the ability of performing "Call Forwarding by ISDN Line, CFU / CFB / CFNR" feature. Note CFU (Call Forwarding Unconditional) CFB (Call Forwarding Busy) CFNR (Call Forwarding No Reply) Reference...
  • Page 66 2.4 Class of Service (COS) Parameter Trunk Group No. 01-48 – Day / Night Default All: Check Value Range No check [Restricted] Check [Not restricted] Description/Function Specifies the trunk group (01-48) which the extension user can use for making an outside call in Day / Night mode respectively on a COS number basis.
  • Page 67: System Timer

    2.5 System Timer 2.5 System Timer 2.5.1 System Timer 1/2 Used to assign various system timers. Parameter Hold Recall Time Default 60 s Value Range 0-240 s Description/Function Specifies the length of time in seconds that the system is to wait before alerting the extension user who held the call by Held Call Reminder ringing.
  • Page 68 2.5 System Timer Parameter Transfer Recall Time Default 12 rings Value Range 0-48 rings Description/Function Specifies the number of rings before transfer recall occurs. If a transferred call is not answered before the programmed number of rings, the call returns to the extension user who originally transferred it or an Operator depending on the setting of "6.
  • Page 69 2.5 System Timer Parameter First Digit Time Default 10 s: [SP], [NL], [JT], 5 s: [G] Value Range 5-120 s Description/Function Specifies the maximum time allowed between the start of an outside dial tone and the first digit dialled on an outgoing call. Reference None Parameter...
  • Page 70 2.5 System Timer Parameter Call Forwarding- No Answer Time Default 3 rings Value Range 1-12 rings Description/Function Specifies the number of rings before the Call Forwarding No Answer feature is activated. If a call is not answered before the programmed number of rings, the call is redirected to the pre-assigned extension.
  • Page 71 2.5 System Timer Parameter Automatic Redial Interval Time Default 60 s Value Range 30-1200 s Description/Function Specifies the interval time between each Automatic Redial attempt. Reference • 1.7 Dialling Features (F/G) – Redial, Automatic Parameter Automatic Redial Repeat Times Default 10 times: [SP], [G], 4 times: [NL], 15 times: [JT] Value Range 0-30 times...
  • Page 72 2.5 System Timer Parameter Timed Reminder Ringing Time Default 30 s Value Range 30-240 s Description/Function Specifies the length of ringing time in seconds of the Timed Reminder alarm. Reference • 1.8 Ringing Features (F/G) – Timed Reminder (Wake-Up Call) –...
  • Page 73 2.5 System Timer Parameter TIE Inter-digit Time Default Value Range 3-30 s Description/Function Specifies the maximum time allowed between digits on a TIE call after it was received by the system. Reference • 3.1 E&M Features (F/G) – E&M (TIE) Line Service Parameter DISA Prolong Time Default...
  • Page 74 2.5 System Timer Parameter Timed Reminder Arrive Count Default 3 times Value Range 1-5 times Description/Function Specifies the number of times (1-5) Timed Reminder / Remote Timed Reminder (Wake-Up Call) is repeated until the destination extension answers it. Reference • 1.8 Ringing Features (F/G) –...
  • Page 75 2.5 System Timer Parameter Intercept Timer after OGM Default Value Range 0: Immediately 5: 5 s later Description/Function Specifies the length of time in seconds the system is to wait after sending OGM before directing the call to the IRNA destination. Reference •...
  • Page 76: Local Hunt Sequence

    2.6 Local Hunt Sequence 2.6 Local Hunt Sequence Specifies the trunk group hunt sequence to be used when an extension user attempts to make an outside call by dialling the feature number for "Local CO Line Access / ARS" or by pressing a Loop-CO key.
  • Page 77: Trunk To Trunk Restriction

    2.7 Trunk to Trunk Restriction 2.7 Trunk to Trunk Restriction Used to allow or restrict the trunk-to-trunk relay function (routing a trunk call from one Trunk Group to another) on a trunk group basis. Please refer to "TIE Line Network - Alternate Routing" in Section "3.1 E&M Features" of the Features Guide for further information.
  • Page 78: System Option

    2.8 System Option 2.8 System Option 2.8.1 System Option 1/4 Used to assign system option parameters (No.1 — No.10). Parameter 1. Sound source during transfer Default Music on Hold Value Range Ringback Tone Music on Hold Description/Function Used to determine whether the system sends "Music on Hold" or "Ringback Tone"...
  • Page 79 2.8 System Option Parameter 2. SLT On-hook with consulting held call Default Consulting Hold Value Range Consulting Hold Disconnect Description/Function Specifies the result of pressing the switchhook lightly and then replacing the handset during an outside call. This setting applies to SLT users only. Reference •...
  • Page 80 2.8 System Option Parameter 5. Limited call duration Default Both calls Value Range Outgoing call only Both calls Description/Function Limited call duration is a system programmable feature that disconnects an outside call when a specified timer expires. A warning tone is sent to the extension user 15 seconds, 10 seconds, and 5 seconds before the time-limit.
  • Page 81 2.8 System Option Parameter 7. Checking dial *, # by toll restriction Default Check Value Range No check [Disable] Check [Enable] Description/Function Specifies whether or not the system checks the user-dialled " " and "#" during Toll Restriction procedure. Note •...
  • Page 82 2.8 System Option Parameter 10. Station Speed Dialing Initial display Default Name Value Range Name Number Description/Function Specifies the initial display of a display DPT, such as KX-T7235 / KX-T7536, in Station Speed Dialling. Reference • 2.10.4 Using the KX-T7531, KX-T7533, KX-T7536 or KX- T7235 (U/M) 2.8.2 System Option 2/4 Used to assign system option parameters (No.11 –...
  • Page 83 2.8 System Option Parameter 12. Automatic adjustment of the clock using Caller ID information Default Value Range Description/Function Enables or disables the automatic adjustment of the clock by Caller ID information once a day. Reference • 1.5 Attended Features (F/G) –...
  • Page 84 2.8 System Option Parameter 15. Special dial tone after setting feature Default Enable Value Range Enable Disable Description/Function If enabled, the system notifies the extension user by sending a special dial tone (Dial Tone 2) when one or more of the following features are assigned on his / her extension.
  • Page 85 2.8 System Option Parameter 17. Destination Busy - DISA Default Send busy tone Value Range Send busy tone Transferred to IRNA destination Description/Function Specifies the treatment of DISA callers when they dial a busy extension. Reference • 1.5 Attended Features (F/G) –...
  • Page 86 2.8 System Option Parameter 20. Off-hook Monitor Default Enable Value Range Enable Disable Description/Function Enables or disables "Off-hook Monitor" feature on a system-wide basis. This feature allows a PT user on a handset call to let other people around him / her monitor the call by pressing the SP- PHONE button.
  • Page 87 2.8 System Option Message waiting lamp patterns (1/2) The available message waiting lamp patterns are as follows: 5.12 1.28 Pattern #01 5.12 1.28 Pattern #02 512 ms 5.12 1.28 Pattern #03 256 ms 2.56 768 ms Pattern #04 256 ms 2.56 512 ms Pattern #05...
  • Page 88 2.8 System Option Message waiting lamp patterns (2/2) 1.28 Pattern #07 256 ms 1.28 Pattern #08 1.28 Pattern #09 t=1.28 Pattern #10 t=1.28 Pattern #11 5.12 768 ms Pattern #12 256 ms System...
  • Page 89 2.8 System Option Parameter 21. Illegal Number - DISA Default Send reorder tone Value Range Send reorder tone Transferred to IRNA destination Description/Function Specifies the treatment of the invalid DISA calls. Reference • 1.5 Attended Features (F/G) – Direct Inward System Access (DISA) Parameter 22.
  • Page 90 2.8 System Option Parameter 25. Pressing DSS key operation in CO talking Default Hold Value Range Disconnect Hold Description/Function If set to "Hold," the PT user engaged in a CO call can transfer the current call to another extension simply by pressing the DSS button associated with the destination extension.
  • Page 91 2.8 System Option Parameter 28. Trunk hunting mode Default Forced Value Range Forced Loop Detection Description/Function Specifies the trunk hunting mode. Forced The system seizes a trunk line whether or not loop current is detected from the local CO. Loop Detection The system seizes a trunk line after detecting loop current from the local CO.
  • Page 92 2.8 System Option Parameter 31. Answering Call Waiting call by SLT hooking Default Disable Value Range Enable Disable Description/Function If enabled, an SLT user can answer a call-waiting call simply by flashing the switchhook. Reference • 1.9 Answering Features (F/G) –...
  • Page 93 2.8 System Option Parameter 33. FWD / DND lamp pattern Default FWD: Flash, DND: On Value Range FWD: Flash, DND: On FWD: On, DND: Flash Description/Function Specifies the lamp patterns of the FWD / DND button. Reference • 1.8 Ringing Features (F/G) –...
  • Page 94 2.8 System Option Parameter 37. Ring Mode Default Type-6: [SP], Type-1: [NL], [G], Type-5: [JT] Value Range Type-1 Type-2 Type-3 Type-4 Type-5 Type-6 Description/Function Specifies the Rigning Tone type. Note • The change of this parameter is activated after resetting the system.
  • Page 95 2.8 System Option Parameter 40. TSW Tone Selection Default TONE-A Value Range TONE-A TONE-B TONE-C TONE-D Description/Function Specifies the tone pattern in the TSW Tone ROM. Reference None Parameter 41. Fixed Feature Number Default Type-2 Value Range Type-1 Type-2 Description/Function Specifies a type of Fixed Feature Numbers.
  • Page 96 2.8 System Option Parameter 44. Hotel Application Default Disable Value Range Enable Disable Description/Function If enabled, the Manager and the Operators can handle "Front / Operator services" such as "Check-in / Check-out." Reference • 1.3 System Features (F/G) – Hotel Application Parameter 45.
  • Page 97 2.8 System Option Parameter 48. Call Pickup with DSS S-CO key Default Disable Value Range Enable Disable Description/Function By default, an S-CO button assigned to a DSS button (on a DSS Console) is available for monitoring the call activity only, not available for making / receiving a call.
  • Page 98: Language Data

    The KX-TD500 System provides two different languages as the Display Language at the same time, which is shown on the display of a Panasonic Proprietary Telephone (PT). Each PT user can choose English (default) or Optional Language, so PTs on the same KX-TD500 System can display different languages.
  • Page 99 2.9 Language Data • You can upload the Language Data after uploading the system data. When system data upload is finished, the "Language Data Selection" dialogue box is displayed. Then you can upload the Language Data in the same way as described in <Uploading the Language Data to the KX-TD500 System>.
  • Page 100 2.9 Language Data System...
  • Page 101: Group

    Section 3 Group Group...
  • Page 102: Group

    3.1 Group 3.1 Group Used to assign various group parameters. Group...
  • Page 103: Trunk Group

    3.2 Trunk Group 3.2 Trunk Group Used to assign parameters for each trunk group. 3.2.1 Trunk Group - Copy Used to copy a part of or all settings of a certain Trunk Group to all other Trunk Groups at a time.
  • Page 104 3.2 Trunk Group 3. Select the Trunk Group parameters to copy in "Copy Item" field. • Items marked with " " are copied. 4. Point to the "Select All" button in the "Destination Trunk Group" field and click. • All displayed Trunk Group Nos. will be marked with " ". •...
  • Page 105 3.2 Trunk Group Parameter Type Default Public Value Range Public Private VPN (Virtual Private Network) Description/Function Specifies the network type for the trunk gruop. Reference None Parameter Tenant No. Default Value Range Description/Function Specifies a tenant number (1-8) to which the trunk group is assigned.
  • Page 106 3.2 Trunk Group Parameter Line Hunting Order Default Normal Value Range Normal Reverse Sequential Description/Function Specifies the hunting sequence of idle lines on a trunk group basis. Normal The system connects the user to an idle trunk line with the lowest physical number.
  • Page 107 3.2 Trunk Group Parameter Pause Time Default 1.5 s: [SP], [NL], 3.5 s: [JT], [G] Value Range 1.5 s 2.5 s 3.5 s 4.5 s Description/Function Specifies the length of pause time (dialling delay). The programmed pause time is automatically inserted after a line access code or a host PBX access code, or manually inserted if the PAUSE button is pressed by the extension user.
  • Page 108 3.2 Trunk Group Parameter Flash Time Default 80 ms: [SP], [NL], [JT], 300 ms: [G] Value Range None 80 ms 300 ms 600 ms 900 ms 1200 ms Description/Function Specifies the length of flash time. Notes • In some countries, the ELCOT card must not be connected to the Public Switched Network.
  • Page 109 3.2 Trunk Group Parameter PBX Access Code Default Blank Value Range 1-4 digits consisting of 0-9, or # Description/Function Specifies the PBX access codes required to access the Host PBX or Centrex service. If the system is installed behind a host PBX or a Centrex system, an access code is required to make an outside / Centrex call or to access Centrex features.
  • Page 110 3.2 Trunk Group Parameter PBX Ringback Tone Default Disable Value Range Enable Disable Description/Function Specifies whether or not the system sends a ringback tone to the extension user who seizes an E1 digital trunk line. (Available for E1 digital trunk lines only.) Notes •...
  • Page 111 3.2 Trunk Group Parameter Silence Detection Default Check Value Range No check [Disable] Check [Enable] Description/Function Used to disconnect the trunk line if the system detects no signal during a CO-to-CO line call by DISA. Reference • 1.5 Attended Features (F/G) –...
  • Page 112 3.2 Trunk Group Parameter [Numbering Plan ID] Incoming—Public Default Default Value Range Default Unknown ISDN / Telephony National Standard Private Description/Function Specifies the Numbering Plan ID applied to the incoming CO calls via ISDN Public Network. Reference None Parameter [Numbering Plan ID] Incoming—Private Default Default Value Range...
  • Page 113 3.2 Trunk Group Parameter [Type of Number] Outgoing—Private Default Default Value Range Default Unknown International National Network Specific Subscriber Description/Function Specifies the Type of Number applied to the outgoing CO calls via ISDN Private Network. Reference None Parameter [Type of Number] Incoming—Public Default Default Value Range...
  • Page 114: Extension Group

    3.3 Extension Group 3.3 Extension Group Used to assign various parameters for up to 128 (1-128) Extension Groups. Which parameters apply to your Extension Group? Please refer to the table on Page 115 and Page 116. Note By default, the Group Type of Group No.126 is VM, No.127 is AA and No.128 is Operator. Group...
  • Page 115 3.3 Extension Group Applicability of Parameters to Group Types Group Type Parameter None Ter. Cir. Ring Ope. Group No. Tenant No. [Overflow Setting] Destination – Day / Night [Overflow Setting] Timer FWD / DND Mode Extension Call Hunting [Operator Setting] Ringing Type [Operator Setting] Call Priority...
  • Page 116 3.3 Extension Group Applicability of Group Types to Overflow Destinations Overflow Destination External Extension Phantom DIL 1:N Group Type Pager Group Group Extension Group None Terminate Circular Operator ( = assignable) 3.3.1 Extension Group - Copy Used to copy a part of or all settings of a certain Extension Group to all other Extension Groups at a time.
  • Page 117 3.3 Extension Group 3. Select the Extension Group parameters to copy in "Copy Item" field. • Only parameters which are available to copy are shown in "Copy Item" field. This depends on the Group Type assignment of the copy source Extension Group. •...
  • Page 118 3.3 Extension Group Parameter Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the FDN (Floating Directory Number) for the Extension Group. Reference • 1.3 System Features (F/G) – Floating Station Parameter Group Type Default Group No.126: VM, Group No.127: AA, Group No.128: Operator, Others: None Value Range None...
  • Page 119 3.3 Extension Group Parameter Tenant No. Default Value Range Description/Function Specifies a tenant number (1-8) to which the Extension Group is assigned. (Required if "Tenant Service" is employed.) Reference •1.3 System Features (F/G) – Tenant Service • 2.2 Tenant (P/G) Parameter [Overflow Setting] Destination –...
  • Page 120 3.3 Extension Group Parameter FWD / DND Mode Default Enable Value Range Disable Enable Description/Function Specifies whether to enable or disable the FWD / DND (Call Forwarding or Do Not Disturb) feature assigned on all extensions in the Extension Group. (Assignable only when "Terminate"...
  • Page 121 3.3 Extension Group Parameter [Operator Setting] Call Priority Default CO Call:1, Intercept Routing:2, Recall:3, Extension Call:4 Value Range Priority 1-4 Description/Function Specifies the answering priority of incoming calls to the Operator Group by a type of call when more than one call is ringing at an Operator extension.
  • Page 122 3.3 Extension Group Parameter [UCD Setting] FWD No Answer Default Disable Value Range Disable Enable Description/Function Specifies the treatment of the call which is not answered by the extension in the UCD group within a specified period of time (Call Forwarding - No Answer Time).
  • Page 123 3.3 Extension Group Parameter [UCD Setting] LOGIN Monitor Default Disable Value Range Disable Enable Description/Function Specifies whether the extension can monitor (through the corresponding DSS buttons) the Login / Logout status of UCD Group members or not. Reference • 1.3 System Features (F/G) –...
  • Page 124: Paging Group

    3.4 Paging Group 3.4 Paging Group Used to programme up to 16 Paging Groups. Each Paging Group consists of up to 24 Extension Groups. One Extension Group can be assigned to only one Paging Group. Parameter Paging Group No. Default Value Range 1-16 Description/Function...
  • Page 125: Dil 1:N Group

    3.5 DIL 1:N Group 3.5 DIL 1:N Group Used to programme a list of up to 96 DIL 1 : N Groups. You can assign up to 72 extensions and / or Extension Groups per DIL 1 : N Group so that an incoming CO call rings multiple extensions simultaneously.
  • Page 126 3.5 DIL 1:N Group Parameter Mailbox No. Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the mailbox number of the DIL 1:N group. When a DIL 1:N call is redirected to a VM extension by IRNA feature, the system sends the digits of this mailbox number to the VPS.
  • Page 127 3.5 DIL 1:N Group Parameter [Destinations] Ringing Type Default Immediate Value Range Immediate 1-ring Delay 3-ring Delay 6-ring Delay No Ring Description/Function Specifies the ringing delay of the calls arriving at extensions in the DIL 1:N group. Immediate: An extension rings immediately. 1-ring Delay: An extension rings in 1-ring delay timing.
  • Page 128: Ogm Group

    3.6 OGM Group 3.6 OGM Group Used to assign parameters for OGM Groups (1-8). OGM resources on the DISA card can be grouped together as an OGM Group. Parameter Group No. Default Value Range Description/Function Specifies the OGM Group (1-8) which you are going to programme.
  • Page 129 3.6 OGM Group Parameter Tenant No. Default Value Range Description/Function Specifies the tenant to which you are going to assign this OGM Group. Reference • 1.3 System Features (F/G) – Tenant Service • 2.2 Tenant (P/G) Parameter OGM Type Default DISA Value Range DISA...
  • Page 130 3.6 OGM Group Parameter Security Mode Default Trunk Value Range None Trunk Description/Function Specifies the Security Mode for DISA callers. None (Non security mode) DISA callers can make both outside and intercom calls via DISA without restriction. Trunk (Trunk Security mode) DISA callers are required to enter a pre-assigned DISA user code to make outside calls via DISA.
  • Page 131: Line

    Section 4 Line Line...
  • Page 132: Line

    4.1 Line 4.1 Line Used to assign various parameters for both trunk and extension lines. Line...
  • Page 133: Trunk Line

    4.2 Trunk Line 4.2 Trunk Line Used to assign various parameters for trunk lines. 4.2.1 Trunk Line - Copy Used to copy a part of or all settings of a certain Trunk Line to all other same type Trunk Lines at a time.
  • Page 134 4.2 Trunk Line 3. Select the Trunk Line parameters to copy in "Copy Item" field. • Only parameters which are available to copy are shown in "Copy Item" field. This depends on the attribute of the copy source Trunk Line. •...
  • Page 135 4.2 Trunk Line Parameter Port No. Default Value Range 1 - n [n = 4 (E&M), n =16 (BRI), n = 30 (PRI30), n = 31 (E1 except Port No.16), n = 8 (Others)] Description/Function Specifies the trunk port which you are going to programme. Note •...
  • Page 136 4.2 Trunk Line Parameter Incoming Type Default (1)DIL:ELCOT card (2)DID:E1[DR2] / E1[E&M-C (MFC-R2)] / E1[E&M-P (MFC-R2)] (3)DDI:BRI / PRI30 card (4) TIE:E1[E&M-C (Pulse, DTMF)] / E1 [E&M-P (Pulse, DTMF)] / E&M card Value Range Line...
  • Page 137 4.2 Trunk Line Parameter Incoming Type Description/Function Specifies how the incoming CO call via this trunk line is routed to the destination in the system. Incoming CO calls are routed by DIL (Direct In Lines) 1:1 or 1:N feature. Incoming CO calls are routed by DID (Direct Inward Dialling) feature.
  • Page 138 4.2 Trunk Line Parameter Incoming Type Reference • 1.5 Attended Features (F/G) – Direct In Lines (DIL) – Direct Inward Dialling (DID) • 2.4 ISDN Attended Features (F/G) – Direct Dialling In (DDI) • 3.1 E&M Features (F/G) – E&M (TIE) Line Service Parameter Dial Type Default...
  • Page 139 4.2 Trunk Line Parameter Destination – Day / Night Default 1001: [SP], [NL], [JT], 2001: [G] Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the destination for the trunk line whose "Incoming Type" is set to "DIL." The following numbers can be assigned as the destination: Extension numbers, FDNs.
  • Page 140 4.2 Trunk Line Parameter [CPC Signal] OUT Detection - Detection Time (ELCOT card) Default 32ms : [SP], None : [NL], [JT], [G] Value Range None 6.5 ms (2-75) 8 ms Description/Function Specifies the expected minimum duration for detecting CPC (Calling Party Control) signal on outgoing CO calls. Note •...
  • Page 141 4.2 Trunk Line Parameter [CPC Signal] IN Detection Default Enable (E1 [DR2], ELCOT card) : [SP], Disable (ELCOT card), Enable (E1 [DR2] card) : [NL], [JT], [G] Value Range Enable Disable Description/Function Specifies whether CPC Detection on incoming CO calls is enabled or disabled.
  • Page 142 4.2 Trunk Line Parameter [CPC Signal] IN Detection - Detection Time (E1 [DR2] card) Default 160 ms Value Range None (1-15) 80 ms Description/Function Specifies the expected minimum duration for detecting CPC (Calling Party Control) signal on incoming CO calls. Note •...
  • Page 143 4.2 Trunk Line Parameter Wink Signal Time-out Default 1024 ms Value Range 64 ms 128 ms 256 ms 512 ms 1024 ms 2048 ms 4096 ms 8128 ms Description/Function Specifies the length of time in milliseconds that the system is to wait for the Wink Signal after seizing the trunk.
  • Page 144 4.2 Trunk Line Parameter Digits to receive DDI / DID Default 4 (E1 [DR2] card), 7 (BRI/PRI30 card): [SP], [NL], [JT] 4 (E1 [DR2] card), 8 (BRI/PRI30 card): [G] Value Range 0-16 digits Description/Function Specifies the number of receiving digits from a DDI / DID trunk. (Assignable only when "Incoming Type"...
  • Page 145 4.2 Trunk Line Parameter [TIE Line] Sending TIE Caller ID Default Value Range Description/Function Specifies whether to send or not the TIE Caller ID to the other end. Reference • 3.1 E&M Features (F/G) – E&M (TIE) Line Service Parameter [TIE Line] TIE-to-CO Security Mode Default Value Range...
  • Page 146 4.2 Trunk Line Parameter [DDI / DID / TIE] Number to be added Default Blank Value Range Max. 8 digits consisting of 0-9 Description/Function Specifies the number (1 to 8 digits) to be added to the number received from the DDI / DID trunk / other PBX via DID / TIE lines. Reference •...
  • Page 147: Extension Line

    4.3 Extension Line 4.3 Extension Line Used to assign parameters for extension lines. 4.3.1 Extension Line - Copy Used to copy a part of or all settings of a certain Extension Line to all other Extension Lines at a time. You can also specify one or several Extension Lines as the copy destination. Copying the Extension Line Parameters to Other Extension Lines 1.
  • Page 148 4.3 Extension Line 3. Select the Extension Line parameters to copy in "Copy Item" field. • Only parameters which are available to copy are shown in "Copy Item" field. This depends on the attribute of the copy source Extension Line. •...
  • Page 149 4.3 Extension Line Parameter Port No. Default Value Range 1-32 Description/Function Specifies the extension port which you are going to programme. Note • Port Nos. 17-32 will be displayed when "DN" and "Group No." for "Ext No.2" are assigned in "1-4 VPS (DPT) Port Assignment"...
  • Page 150 4.3 Extension Line Parameter Name Default Blank Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies the name for the extension line.
  • Page 151 4.3 Extension Line Parameter Mailbox No. Default Same as the extension number Value Range Up to 16 digits consisting of 0 - 9, , # or P [Pause] Description/Function Specifies the Mailbox Number, which is usually the same as the extension number.
  • Page 152 4.3 Extension Line Parameter Message Lamp Default Value Range Description/Function Assigns whether an SLT with MESSAGE lamp can receive the message waiting indication or not. (Assignable when an SLT with Message lamp is interfaced by an ESLC card.) Reference • 1.17 Display Features (F/G) –...
  • Page 153 4.3 Extension Line Parameter [Preferred Line] Incoming Default Ringing Line Value Range No Line Ringing Line Prime Line - ICM / PDN Prime Line - CO Description/Function Specifies the line to which the extension is connected when it goes off-hook to answer a call. Reference •...
  • Page 154 4.3 Extension Line Parameter [LCS Setting] Operation Mode Default Hands-free Value Range Private Hands-free Description/Function Assigns whether the voice message being recorded is monitored automatically through the built-in speaker (Hands-free mode) or an alert tone is sent (Private mode) while an incoming caller is leaving a message in the mailbox of the extension.
  • Page 155 4.3 Extension Line Parameter [Call Log Incoming] Overwrite Mode Default Value Range Description/Function Enables or disables Call Log Incoming, Overwrite Mode. If the Call Log is full (30 call records are already logged) when a new Caller ID call comes in. Yes : The new call record overwrites the oldest one in the Call Log.
  • Page 156 4.3 Extension Line Parameter [Pickup Dialing] Dial Default (Display only) Value Range Up to 24 digits Description/Function Displays the telephone number for "Pickup Dialling" feature. The system automatically dials this number when an extension user goes off-hook to make a call, if "Pickup Dialling" is enabled. Reference •...
  • Page 157 Value Range English Option Description/Function Specifies the language shown on a PANASONIC display PT. The language is set for each extension, so phones on the same system can display different languages. Note • French is stored as default Optional Language at the factory.
  • Page 158 4.3 Extension Line Parameter [CLIP / COLP Number] Public Default Blank Value Range Up to 16 digits consisting of 0 - 9, or P [PAUSE] Description/Function Specifies a CLIP / COLP number used for the incoming / outgoing calls via Public Network to each extension. Note •...
  • Page 159 4.3 Extension Line Parameter Charge Limit Default Value Range 0: No limit 1-99999: The number of charge meter allowable for the extension Description/Function Used to determine the sum total of telephone charge allowable to extension users on an extension basis. If the telephone charge on the extension exceeds the limit, a toll call cannot be made anymore from that extension.
  • Page 160 4.3 Extension Line 4.3.2 Flexible CO Key Assignment Used to determine the usage of flexible CO buttons on PTs. The following screen is displayed by clicking "CO Key" button on "4-2 Extension Line" screen. <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Not Stored" button for each CO key on the above screen.
  • Page 161 4.3 Extension Line <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Parameters Description (default) SINGLE-CO Trunk Line No. Specifies the trunk port physical number (10101 to 31416). Tone (2) Specifies the ringer frequency (ring tone type: 1-8) for incoming calls.
  • Page 162 4.3 Extension Line Additional Key Type Parameters Description (default) Dial Specifies the telephone number or feature access number (up to 24 digits consisting, of 0-9, , #, -, P, S or F). Note P: Pause, S; Secret Dialling, F: Hook Flash Line...
  • Page 163 4.3 Extension Line Parameter Key Type Default CO-01 : Loop-CO, Others : Not Stored Value Range Please refer to "Description / Function." Description/Function Not Stored: Key Type is not assigned. SINGLE-CO: Single-CO button GROUP-CO: Group-CO button LOOP-CO: Loop-CO button DSS: Direct Station Selection button PHANTOM: Phantom button PDN: Primary Directory Number button SDN: Secondary Directory Number button...
  • Page 164 4.3 Extension Line 4.3.3 Flexible PF Key Assignment for PT Used to determine the usage of flexible PF buttons on PTs. The following screen is displayed by clicking "PF Key" button on "4-2 Extension Line" screen. <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Not Stored" button for each PF Key on the above screen.
  • Page 165 4.3 Extension Line <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Description Parameters ONE-TOUCH Dial Specifies the telephone number or feature access number (up to 24 digits consisting of 0 - 9, , #, -, P, S or F). Note P: Pause, S: Secret Dialling, F: Hook Flash Name...
  • Page 166: Dss Console

    4.4 DSS Console 4.4 DSS Console Used to assign the paired extension for a DSS (Direct Station Selection) Console and the usage of DSS and PF buttons. 4.4.1 DSS Console - Copy Used to copy a part of or all settings of a certain DSS Console to all other DSS Consoles at a time.
  • Page 167 4.4 DSS Console 3. Select the DSS Console parameters to copy in "Copy Item" field. • Items marked with " " are copied. 4. Point to the "Select All" button in the "Destination DSS Console" field and click. • All displayed Extension Line Nos. will be highlighted. •...
  • Page 168 4.4 DSS Console Parameter [DSS Console 1-8] Port No. Default (Display only) Value Range Extension port physical number Description/Function Displays the extension port to which the DSS console is connected. Reference • 1.15 Proprietary Telephone Features (F/G) – DSS Console •...
  • Page 169 4.4 DSS Console 4.4.2 Flexible DSS Key Assignment Used to determine the usage of flexible DSS buttons on DSS Consoles. The following screen is displayed by clicking "DSS Key" button on "4-3 DSS Console" screen. <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Not Stored" button for each DSS Key on the above screen.
  • Page 170 4.4 DSS Console <Additional Parameters Required by Key Type> Depending on a Key Type, additional parameters are required as follows. Additional Key Type Description Parameters SINGLE-CO Trunk Line No. Specifies the trunk port physical number (10101 to 31416). Tone Since any call does not come in on a DSS button with the current TD500 software, this setting is not required.
  • Page 171 4.4 DSS Console Parameter Key Type Default Not Stored Value Range Please refer to "Description / Function." Description/Function Not Stored: Key Type is not assigned. SINGLE-CO: Single-CO button GROUP-CO: Group-CO button DSS: Direct Station Selection button ONE-TOUCH: One-Touch Dial button MESSAGE: Message Waiting button FWD / DND: Call Forwarding / Do Not Disturb button SAVE: Saved Number Redial button...
  • Page 172 4.4 DSS Console <Key Type Assignment> The following Key Type Assignment screen is displayed by clicking "Not Stored" button for each PF Key on the above screen. Line...
  • Page 173 4.4 DSS Console Additional Parameters Required by Key Type Depending on a Key Type, additional parameters are required as follows. Additional Key Type Description Parameters ONE-TOUCH Dial Specifies the telephone number or feature access number (up to 24 digits consisting of 0 - 9, , #, -, P, S or F). Note P: Pause, S: Secret Dialling, F: Hook Flash Name...
  • Page 174: Doorphone

    4.5 Doorphone 4.5 Doorphone Used to assign the destination extensions for incoming calls from doorphones. Note • The DPH card is not available in some countries. Parameter Card No. Default — Value Range XXX : DPH [XXX : Card No. (101-314)] Description/Function Specifies the physical number of a doorphone card which you are going to programme.
  • Page 175 4.5 Doorphone Parameter Tenant No. Default Value Range 1 - 8 Description/Function Specifies the tenant number to which the doorphone port is assigned. Reference • 1.3 System Features (F/G) – Tenant Service • 1.12 Conversation Features (F/G) – Doorphone Call •2.2 Tenant (P/G) Parameter Destination –...
  • Page 176: External Paging

    4.6 External Paging 4.6 External Paging Used to assign parameters for External Paging. Parameter Pager No. Default (Display only) Value Range 1, 2 Description/Function Displays the Pager No. Reference •2.8.2 External Pager (Paging Equipment) (I/M) Parameter Tenant No. Default Value Range Description/Function Specifies the tenant to which the External Pager is assigned.
  • Page 177 4.6 External Paging Parameter Default Blank Value Range 3-4 digits consisting of 0-9 Description/Function Specifies the FDN (Floating Directory Number) for the External Pager. Reference • 1.3 System Features (F/G) – Floating Station Parameter Default No check Value Range No check [Disable] Check [Enable] Description/Function Specifies whether BGM is sent or not when the External Pager is...
  • Page 178: Isdn Extension Line

    4.7 ISDN Extension Line 4.7 ISDN Extension Line Used to assign parameters for ISDN Extension Lines. Parameter Card No. Default — Value Range XXX: BRI [XXX: Card No. (101-314)] Description/Function Spesifies the physical number of the BRI card which you are going to programme.
  • Page 179 4.7 ISDN Extension Line Parameter Group No. Default (Display only) Value Range 1-128 Description/Function Displays the Extension Group to which the selected ISDN extension port is assigned. Reference • 1.8 BRI Port Assignment (P/G) Parameter Name Default Blank Value Range Up to 10 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ;...
  • Page 180 4.7 ISDN Extension Line Parameter ISDN Bearer Mode Default Automatic Value Range Automatic Speech 3.1 KHz Audio Description/Function Specifies the ISDN Bearer Mode on an ISDN extension basis. Note • When "Automatic" (Default) is selected, Bearer Mode is set automatically depending on the type of extension telephone as follows: PT –...
  • Page 181 4.7 ISDN Extension Line Parameter [CLIP / COLP Number] Public Default Blank Value Range Up to 16 digits consisting of 0-9, or P [PAUSE] Description/Function Specifies a CLIP / COLP number used for the incoming / outgoing calls via Public Network to each ISDN extension. Note •...
  • Page 182 4.7 ISDN Extension Line Parameter [COS No.] Primary Default Value Range 1-96 Description/Function Spesifies the Primary COS (Class of Service) number to the ISDN extension. Reference •1.3 System Features (F/G) – Class of Service (COS) •3.1.5 Changing Service Level of Extensions (Switching COS) (U/ Parameter [COS No.] Secondary Default...
  • Page 183: Features

    Section 5 Features Features...
  • Page 184: Features

    5.1 Features 5.1 Features Used to assign parameters for various system features. Features...
  • Page 185: System Speed Dialling

    5.2 System Speed Dialling 5.2 System Speed Dialling Used to programme a list of up to 1000 (000-999) frequently dialled numbers per tenant. Anyone in the same tenant can dial these numbers. Up to 2000 Speed Dialling codes can be shared among tenant under the limitation of 1000 codes per tenant.
  • Page 186 5.2 System Speed Dialling Parameter Max. Entry Default (Display only) Value Range 0-1000 Description/Function Displays the maximum number of Speed Dialling codes allocated to the tenant. Reference None Parameter Current Registration Default (Display only) Value Range 0-1000 Description/Function Displays the total number of Speed Dialling codes which are already programmed.
  • Page 187: Phantom Extension

    5.3 Phantom Extension 5.3 Phantom Extension Used to register up to 448 Phantom Extension numbers. Parameter Entry No. Default 001-048 Value Range 001-448 in 48 codes increments Description/Function Specifies the entry number of phantom extension number which you are going to programme. Reference •...
  • Page 188: Emergency Dial Code

    5.4 Emergency Dial Code 5.4 Emergency Dial Code Used to programme a list of up to 10 emergency numbers that any extension in the system can dial at any time, regardless of dialling restrictions. Parameter Dial Default All: Blank: [SP], [NL], [JT], 1: 110, 2: 112: [G] Value Range Up to 8 digits consisting of 0-9 Description/Function...
  • Page 189: Quick Dialling

    5.5 Quick Dialling 5.5 Quick Dialling Used to store up to eight Quick Dial numbers. Parameter Dial Default All:Blank Value Range Up to 16 digits consisting of 0-9, , #, F, P, S or "-" (hyphen) Description/Function Specifies the phone number for Quick Dialling. Note •...
  • Page 190: Account Code

    5.6 Account Code 5.6 Account Code Used to programme a list of up to 1000 account codes which are used to identify incoming and outgoing CO calls for accounting and billing purposes. Parameter Tenant No. Default Value Range Description/Function Specifies the tenant to which a list of Account Codes is assigned. (Required when "Tenant Service"...
  • Page 191 5.6 Account Code Parameter Code Default Blank Value Range Up to 10 digits consisting of 0-9 Description/Function Specifies the account codes. Reference • 1.3 System Features (F/G) – Account Code Entry • 2.2.5 Calling without Restrictions (U/M) Parameter TRS Level Default None Value Range...
  • Page 192: Special Carrier Code

    5.7 Special Carrier Code 5.7 Special Carrier Code Used to programme a list of up to 100 Special Carrier Codes. Parameter Code Default Blank Value Range Up to 10 digits consisting of 0-9, , # or X Description/Function Specifies special carrier access codes. Notes •...
  • Page 193: Absent Message

    5.8 Absent Message 5.8 Absent Message Used to programme a list of up to nine absent messages. An absent message, if set by the extension user, is displayed on the calling extension's display PT to show the reason of absence (no answer). Features...
  • Page 194 5.8 Absent Message Parameter Message Default MSG1: Will Return Soon, MSG2: Gone Home, MSG3: At Ext %%%% (Extension No.), MSG4: Back at %% : %% (Hour: Minute), MSG5: Out Until %% / %% (Day / Month): [SP], [NL], [JT], (Month / Day): [G], MSG6: In a Meeting, MSG7-9: Blank Value Range Up to 16 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ %...
  • Page 195: Disa / Tie User Code

    5.9 DISA / TIE User Code 5.9 DISA / TIE User Code Used to programme a list of up to 32 DISA / TIE User Codes. Each code is appended with a COS level. Features...
  • Page 196 5.9 DISA / TIE User Code Parameter Code Default All: Blank Value Range 4-10 digits consisting of 0-9 Description/Function Specifies the User Codes for DISA / TIE feature. Notes • DISA user code is required when the DISA caller attempts to make an outside call (Trunk Security mode) or to make either extension or outside call (All Security mode).
  • Page 197: Vps Integration

    5.10 VPS Integration 5.10 VPS Integration 5.10.1 VPS Integration 1/2 Used to assign Integration Code and Voice Mail Command for VPS Integration. Integration Code When DTMF tone Integration is activated, the KX-TD500 informs the VPS (Voice Processing System) of the state of the call (busy, answered, ringing, etc.) by sending a code with DTMF tone before sending the normal call progress tone (busy tone, ringback tone, etc.).
  • Page 198 5.10 VPS Integration Parameter Busy Tone Default Value Range Up to 3 digits consisting of 0-9, or # Description/Function Specifies the Busy Tone code. Sent to the VPS when the extension it dialled is busy. Reference • 1.3 System Features (F/G) –...
  • Page 199 5.10 VPS Integration Parameter Extension Disconnection Default Value Range Up to 3 digits consisting of 0-9, or # Description/Function Specifies the Extension Disconnection code. Sent to the VPS when the calling party hangs up. Reference • 1.3 System Features (F/G) –...
  • Page 200 5.10 VPS Integration Parameter FWD to Extension Ringback Tone Default Value Range Up to 3 digits consisting of 0-9, or # Description/Function Specifies the FWD to Extension Ringback Tone code. Sent to the VPS if the caller is forwarded to another, non-voice mail extension.
  • Page 201 5.10 VPS Integration Parameter AA Service Default Value Range Up to 16 digits consisting of 0-9, , # or H Description/Function Specifies the AA (Automated Attendant) Service command. If AA Service is set to "Start" by System Programming, this command is sent to a VM port if an incoming CO call is answered by the VM port.
  • Page 202 5.10 VPS Integration Parameter DTMF signal duration Default 80 ms Value Range 80 ms 160 ms Description/Function Specifies the duration of the DTMF signals sent to the VPS (Voice Processing System) ports. Reference • 1.3 System Features (F/G) – Integration, VPS Parameter Pause timing before sending DTMF signal (Follow on ID) Default...
  • Page 203 5.10 VPS Integration Parameter Pause timing before sending DTMF signal (RBT, BT) Default 1.5 s Value Range 0.5 s 1.0 s 1.5 s 2.0 s Description/Function Specifies the length of time in seconds the system is to wait before sending Integration Code with DTMF signals (System- Voice Mail, Extension Status).
  • Page 204 5.10 VPS Integration Parameter Extension's mailbox number Default Programmed number Value Range Extension number Programmed number Description/Function Specifies if an extension's mailbox number is substituted by the extension number or it is programmable (free). If a call is forwarded or rerouted to the VPS, the system automatically transmits the mailbox number to the VPS to specify the extension user's mailbox.
  • Page 205 5.10 VPS Integration Parameter Sending out Follow on ID after IRNA Default Disable Value Range Disable Enable Description/Function Specifies whether or not the system sends Follow on ID to a VPS port after redirecting a call (IRNA) to the VPS port. Reference •...
  • Page 206: Caller Id Modification

    5.11 Caller ID Modification 5.11 Caller ID Modification Used to modify the telephone number sent from the Central Office by Caller ID Service to make up a telephone number for callback purposes. Parameter [Local Call] Area Code Default Blank Value Range Up to 6 digits consisting of 0-9 Description/Function Specifies the area code of the location where your KX-TD500...
  • Page 207 5.11 Caller ID Modification Parameter [Local Call] Digits to delete Default No.1: 3, Others: 0 Value Range Description/Function Specifies the number of digits to be deleted from the telephone number (sent from the Central Office by Caller ID Service) to make up a telephone number for local call.
  • Page 208 5.11 Caller ID Modification Parameter [Long Distance Call] Number to be added Default Value Range Up to 4 digits consisting of 0-9, or # Description/Function Specifies the number to be added to the telephone number (sent from the Central Office by Caller ID Service) to make up a telephone number for long distance call.
  • Page 209: Caller Id Registration

    5.12 Caller ID Registration 5.12 Caller ID Registration Used to assign the Caller ID code (identification code of the calling party) to utilise Caller ID Service provided by a specific Central Office (CO). If an ID Code transmitted from CO is found in the Caller ID Code Table, the caller's ID Code or a name given to the code is displayed on the display PT, allowing the called party to recognise the caller before answering a call.
  • Page 210 5.12 Caller ID Registration Parameter Entry No. Default 0001-0010 Value Range 0001-1000 in 10 codes increments Description/Function Specifies the entry number of Caller ID codes which you are going to programme. Reference None Parameter Name Default Blank Value Range Up to 16 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ;...
  • Page 211: Ucd Time Table

    5.13 UCD Time Table 5.13 UCD Time Table If all extensions in a UCD group are busy, the incoming CO calls will be handled by the UCD Time Table procedure. Up to 32 UCD Time Tables, max.16 steps for each, can be assigned. Parameter Table No.
  • Page 212 5.13 UCD Time Table Parameter Command Sequence (1-16) Default Command No.1 of all tables:1T, Others: None Value Range None, S1 - S8, 1T - 4T, TR, RET, OFF Description/Function The following commands are provided to construct a UCD Time Table procedure. <Commands list and their functions>...
  • Page 213: Charge

    5.14 Charge 5.14 Charge Used to assign parameters for the Charge Fee Management feature. Parameter Charge Display on LCD Default Meter Value Range Meter Charge Description/Function Specifies the initial display format of the charge fee on a display Reference • 1.3 System Features (F/G) –...
  • Page 214 5.14 Charge Parameter [Charge Verification ID Code] Tenant 1-8 Default 1234 Value Range 4-7 digits consisting of 0-9 Description/Function Specifies the ID code required for the charge management. When "Tenant Service" is employed, the password for each tenant (Tenant 1 to 8) can be assigned respectively. Reference •...
  • Page 215 5.14 Charge Parameter Currency Display Position Default Tail Value Range Head Tail Description/Function Specifies whether the currency of the charge is displayed before (Head) or after (Tail) the charge display. Reference None Parameter Treatment of Charge Limit Default Alarm Tone Value Range Alarm Tone Alarm Tone and Disconnect...
  • Page 216: Hotel

    5.15 Hotel 5.15 Hotel Used to assign parameters for Hotel Application. Parameter Title Header (3 lines) Default Check Out Sheet Value Range Characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ ( ) + , - / : ; < = > ? @ &. Description/Function Defines the "Title Header"...
  • Page 217 5.15 Hotel Parameter [Header Start] Column Default Value Range 1-40 Description/Function Specifies the start column of the header. Reference None Parameter [Data Start] Line Default Value Range 4-24 Description/Function Specifies the start line of the data portion. Reference None Parameter [Data Start] Column Default Value Range...
  • Page 218 5.15 Hotel Features...
  • Page 219: Toll Restriction

    Section 6 Toll Restriction Toll Restriction...
  • Page 220: Toll Restriction

    6.1 Toll Restriction 6.1 Toll Restriction Used to assign TRS (Toll Restriction) Deny Codes and TRS Exception Codes. Toll Restriction...
  • Page 221: Trs Deny Code

    6.2 TRS Deny Code 6.2 TRS Deny Code Used to programme a list of up to 400 TRS (Toll Restriction) Deny Codes - telephone numbers that extension users cannot dial. Parameter TRS Level Default Value Range 2 - 6 Description/Function Specifies a TRS (toll restriction) level.
  • Page 222 6.2 TRS Deny Code Parameter Dial Default Blank: [SP], [NL], [JT], XXXXXXX: [G] (Level 2 only) Value Range Up to 10 digits consisting of 0-9, X, or # Description/Function Specifies the leading 10 digits of the toll-restricted telephone numbers. Note •...
  • Page 223: Trs Exception Code

    6.3 TRS Exception Code 6.3 TRS Exception Code Used to programme a list of numbers that an extension is allowed to dial, even if these numbers are listed in a TRS Deny Code Table. Up to 200 TRS Exception codes can be assigned. Parameter TRS Level Default...
  • Page 224 6.3 TRS Exception Code Parameter Dial Default Blank: [SP], [NL], [JT], XXXXXXX: [G] (Level 2 only) Value Range Up to 10 digits consisting of 0-9, X, or # Description/Function Specifies the leading 10 digits of the telephone numbers which are excepted from the toll restriction.
  • Page 225: Ars (Automatic Route Selection)

    Section 7 ARS (Automatic Route Selection) ARS (Automatic Route Selection)
  • Page 226: Ars (Automatic Route Selection)

    7.1 ARS (Automatic Route Selection) 7.1 ARS (Automatic Route Selection) Used to assign ARS parameters. ARS (Automatic Route Selection)
  • Page 227: Time Table

    7.2 Time Table 7.2 Time Table Used to make up ARS time schedules. It is possible to split a day into four time zones (maximum) so that the least expensive line is selected for that time. Enter the starting time of each zone according to the service hours and charges offered by your carriers.
  • Page 228: Leading Digits Table

    7.3 Leading Digits Table 7.3 Leading Digits Table Used to determine the appropriate Route Plan Table number for a call by analysing the extension user-dialled number. Up to 800 Leading Digits entries can be programmed in the system. Parameter Entry No. Default 001-020 Value Range...
  • Page 229 7.3 Leading Digits Table Parameter Dial Default Blank Value Range Up to 10 digits consisting of 0-9, , # or X Description/Function Specifies the leading 10 digits of the telephone number which will be routed by ARS procedure. Note • "X" can be used as a wild card character which substitutes any digit in its position.
  • Page 230: Routing Plan

    7.4 Routing Plan 7.4 Routing Plan Used to specify the Trunk Group number (01-48) and Modified Digit Table number (01-48) to be used for each route plan and time schedule. Up to 48 Routing Plan entries can be programmed in the system. Parameter Plan No.
  • Page 231 7.4 Routing Plan Parameter [Time-A, -B, -C, -D] Modification Table No. Default None Value Range None, 1-48 Description/Function Specifies the MOD (Modified Digit) table number which is used to modify the user-dialled number so that it matches the requirements of the carrier. Reference •...
  • Page 232: Digits Modification Table

    7.5 Digits Modification Table 7.5 Digits Modification Table Used to modify the user-dialled number so that it matches the requirements of the carrier. Up to 48 Digits Modification entries can be programmed in the system. Parameter Entry No. Default 01-08 Value Range 01-48 in 8 entries increments Description/Function...
  • Page 233 7.5 Digits Modification Table Parameter Number to be added Default Blank Value Range Up to 20 digits consisting of 0-9, , # or P [Pause] Description/Function Specifies the dialling number to be added to the beginning of the user-dialled number. Reference •...
  • Page 234 7.5 Digits Modification Table ARS (Automatic Route Selection)
  • Page 235: Private Network

    Section 8 Private Network Private Network...
  • Page 236: Private Network

    8.1 Private Network 8.1 Private Network Used to assign parameters required to utilise TIE line service. Private Network...
  • Page 237: Tie Routing Table

    8.2 TIE Routing Table 8.2 TIE Routing Table Used to specify trunk groups and parameters required for making TIE calls. This table is referenced by the system to identify the trunk route, when an extension user made a TIE call by dialling the feature number for "TIE Line Access" or "Other PBX Extension number."...
  • Page 238 8.2 TIE Routing Table Parameter Leading Digit Default Blank Value Range Up to 3 digits consisting of 0-9 or X Description/Function Specifies the leading one, two or three digits of the number for TIE calls. Used to determine the trunk group for routing a TIE call. Note •...
  • Page 239: Ddi / Did

    Section 9 DDI / DID DDI / DID...
  • Page 240: Ddi / Did

    9.1 DDI / DID 9.1 DDI / DID Used to assign parameters required to utilise DDI / DID service. DDI / DID...
  • Page 241: Number Transformation

    9.2 Number Transformation 9.2 Number Transformation 9.2.1 Number Transformation Used to specify several parameters for DDI / DID / MSN service. Parameter Entry No. Default 0001-0010 Value Range 0001-1000 in 10 entries increments Description/Function Specifies the entry number of DDI / DID / MSN No. which you are going to programme.
  • Page 242 9.2 Number Transformation Parameter DDI / DID / MSN No. Default Blank Value Range Up to 16 digits consisting of 0-9 Description/Function Specifies the DDI / DID / MSN number which will be sent from the Central Office to the KX-TD500 system. Note •...
  • Page 243 9.2 Number Transformation Parameter MSN Line No. Default Blank Value Range Physical number of the trunk port Description/Function Specifies the physical number of the trunk port. This port will be used to forward a call by ISDN Line. Reference • 2.4 ISDN Attended Features (F/G) –...
  • Page 244 9.2 Number Transformation Entry No.1 : 123456 (00) Entry No.2 : 123456 (01) Entry No.3 : 123456 (02) • • • • Entry No.99 : 123456 (98) Entry No.100 : 123456 (99) Notes • If more than 15 digits are entered in "[Base Number] Dial" field, the following warning message will be displayed: "W9005 : Base dial number must not exceed 15 digits.
  • Page 245 9.2 Number Transformation Parameter [Additional Number] Number of Digits Default 2 digits (00-99) Value Range 1-16 digits in 1 digit increment Description/Function Specifies the number of digits to be added to the end of the Base Number. Reference Parameter Beginning Entry No. Default 1 (Entry No.1) Value Range...
  • Page 246 9.2 Number Transformation DDI / DID...
  • Page 247: Maintenance

    Section 10 Maintenance Maintenance...
  • Page 248: Maintenance

    10.1 Maintenance 10.1 Maintenance Used to assign parameters for system maintenance. Maintenance...
  • Page 249: External Modem 1/2

    10.2 External Modem 1/2 10.2 External Modem 1/2 The system supports an external modem plugged into the RS-232C port for remote system administration. Parameter Manual Initialization Command (1- 5) Default All:Blank Value Range Up to 80 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ;...
  • Page 250 10.2 External Modem 1/2 Parameter Automatic Initialization Command Default AT&F0Q0E0V1S0=1X0&D0 Value Range Up to 80 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies Modem Automatic Initialisation Command.
  • Page 251: External Modem 2/2

    10.3 External Modem 2/2 10.3 External Modem 2/2 Parameter Connection Message (1-5) Default Message 1: CONNECT, Others: Blank Value Range Up to 80 characters consisting of 0-9, A-Z, a-z or the following marks: ! # $ % ( ) + , - / : ; < = > ? @ &. Description/Function Specifies Connection Message from Modem.
  • Page 252: Smdr

    10.4 SMDR 10.4 SMDR Station Message Detail Recording (SMDR) automatically records detailed information for outside calls. Parameter SMDR Connection Default Value Range Description/Function Enables or disables SMDR. Reference • 2.8.4 Personal Computer/Printer (I/M) Maintenance...
  • Page 253 10.4 SMDR Parameter Output Type Default Type-A Value Range Type-A Type-B Type-C Type-D Description/Function Specifies the output type of SMDR information. For further information, please refer to "Station Message Detail Recording (SMDR)" in Section "1.3 System Features" of the Features Guide. You can also get information on "Output Type"...
  • Page 254 10.4 SMDR Parameter [Format] Skip Perforation Default Value Range 0-95 lines Description/Function Determines the number of lines to be skipped at the end of every page. The number of lines to skip is simply the number specified in this parameter. The number of lines printed is the difference between the Page Length number and the Skip Perforation number.
  • Page 255 10.4 SMDR Parameter Priority of Caller ID information Default Number Value Range Number Name Description/Function SMDR can print out Caller ID information. This setting specifies whether priority is given to Caller ID Name or to Caller ID Number. However, SMDR can print out both when "Type-D" is specified as Output Type.
  • Page 256 10.4 SMDR Parameter Print out No Answer of Timed Reminder information Default Disable Value Range Enable Disable Description/Function If this is enabled, SMDR will print out "Timed Reminder / Start" each time the timed reminder alarm starts ringing. In addition, if the ringing is not stopped by going off-hook, the SMDR will print out "Timed Reminder / No Answer."...
  • Page 257 10.4 SMDR Parameter Print out Absent Message (6-9) Default Disable Value Range Enable Disable Description/Function Specifies whether or not Absent Message (6-9) will be printed out by SMDR. If enabled, any extension user can activate the printout by setting the Absent Message (6-9). Reference •...
  • Page 258: Power Failure Transfer

    10.5 Power Failure Transfer 10.5 Power Failure Transfer Power Failure Transfer connects specific telephones (any SLT and a certain type of APT) to pre-determined CO lines in the event of system power failure. Parameter Trunk Card (1-24) Default None Value Range None, XXX : YYY [XXX : Card No.
  • Page 259 10.5 Power Failure Transfer Parameter Extension Card (1-24) Default None Value Range None, XXX : YYY [XXX : Card No. (101-314), YYY : Card Type] Description/Function Specifies the extension card number and its type, which will be used in case of Power Failure Transfer. Notes •...
  • Page 260: System Parameters

    10.6 System Parameters 10.6 System Parameters Used to assign various system parameters. Parameter [Password] System Programming Default 1234 Value Range 4-7 digits of alphanumeric characters Description/Function Specifies the password required for entering System Programming mode and Maintenance from a Personal Computer. Reference •...
  • Page 261 10.6 System Parameters Parameter [Password] Walking COS Default 1234 Value Range 4-7 digits consisting of 0-9 Description/Function Specifies the password required for using the Walking COS feature. Reference • 1.6 Originating Features (F/G) – Walking COS • 2.2.5 Calling without Restrictions (U/M) [Serial Interface Port] PROG (Port 1) Please refer to "System Programming and Diagnosis with Personal Computer"...
  • Page 262 10.6 System Parameters Parameter [Serial Interface Port] PROG – Word Length Default (Display only) Value Range 8 bits Description/Function Defines the number of bits in each byte or character. Note • Port 1 is fixed to 8 bits. Reference None Parameter [Serial Interface Port] PROG –...
  • Page 263 10.6 System Parameters Parameter [Serial Interface Port] SMDR – Parity Default None Value Range None Mark Space Even Description/Function A parity code indicates what type of parity is used to detect an error in the string of bits composing a character. Make an appropriate selection depending on the requirements of your printer or personal computer.
  • Page 264 10.6 System Parameters Parameter [Serial Interface Port] SMDR – Stop Bit Default 1 bit Value Range 1 bit 2 bits Description/Function A stop bit code indicates the end of a bit string which composes a character. Select an appropriate value depending on the requirements of your printer or personal computer.
  • Page 265: System Time

    10.7 System Time 10.7 System Time Used to assign System Time. Please refer to the following: • 1.8 Ringing Features (F/G) – Timed Reminder (Wake-Up Call) – Timed Reminder, Remote (Wake-Up Call) • 1.17 Display Features (F/G) – Display, Date and Time •...
  • Page 266 10.7 System Time Parameter (Month) Default Value Range Jan-Dec Description/Function Selects the month by clicking the small triangle. Reference None Parameter (Day) Default Value Range 01-31 Description/Function Specifies the date in two digits by entering the value directly. Reference None Parameter (Day of the week) Default...
  • Page 267 10.7 System Time Parameter (AM / PM) Default Value Range AM / PM Description/Function Selects AM / PM by clicking the small triangle. Reference None Maintenance...
  • Page 268 10.7 System Time Maintenance...
  • Page 269: Programming Error Messages

    Section 11 Programming Error Messages Programming Error Messages...
  • Page 270: Error Messages (Exxxx)

    11.1 Error Messages (EXXXX) 11.1 Error Messages (EXXXX) Error Message Error Code Description E0000 System error. (Error code : XXX) A system error occurred. Please inform your distributor how the error was generated and what the error code was. E0001 Cannot create temporary file.
  • Page 271 11.1 Error Messages (EXXXX) Error Message Error Code Description E0012 Another maintenance device is connected. There are three ways to access the PBX: (1) By PC System Programming, (2) by Remote System Programming, or (3) by User Programming. But only one at a time. E0013 Please reconnect after the PBX becomes on-line or off-line completely.
  • Page 272 11.1 Error Messages (EXXXX) Error Message Error Code Description E1007 You have exceeded the system limit of remote cards. One ERMT card can be installed in the system -- only one. E1008 You have exceeded the system limit of DPH cards. There is a limit of two DPH cards per system.
  • Page 273 11.1 Error Messages (EXXXX) Error Message Error Code Description E1025 Specify the extension group number. The extension group number of VPS port should be always assigned. E1026 Port number duplicated. Please assign the port number of TVP uniquely. E1028 Card type should be changed only in OUS (Out-of-Service) status. Please make the card OUS (Out-of-service) status before deleting the card.
  • Page 274 11.1 Error Messages (EXXXX) Error Message Error Code Description E1050 The slot next to PRI card must be empty. Please remove and re-assign the card that is installed next to a PRI card. A PRI card must go into slot no. 1, 3, 5, 7, 9, 11 or 13. E1051 E1 card should be assigned to the slot no.
  • Page 275 11.1 Error Messages (EXXXX) Error Message Error Code Description E2010 Feature number duplicated. Feature numbers can be from 1 to 4 digits and shouldn't be any conflicts. The following are examples of feature number conflicts. Examples: N and NX, NXX / NM and NML ( NL is allowed.) E2011 Out of range.
  • Page 276 11.1 Error Messages (EXXXX) Error Message Error Code Description E4005 Invalid Station Lock password. The Station Lock password must be 3 digits (0~9). E4006 Specify trunk line no. Trunk line no. must be specified when Single-CO key is assigned. E4007 Single - CO key duplicated.
  • Page 277 11.1 Error Messages (EXXXX) Error Message Error Code Description E4022 Cannot assign PDN key as Prime Line - CO. Please assign key number except for PDN key when the outgoing or incoming preferred line is set to "Prime Line - CO." E4023 Illegal trunk group number.
  • Page 278 11.1 Error Messages (EXXXX) Error Message Error Code Description E5006 Cannot assign more than 1000 account codes. There is a limit of 1000 account codes per system. E5007 You have exceeded the tenant limit of Speed Dialing numbers. The maximum number of Speeding Dialling numbers per tenant is specified in the "2-1 Tenant"...
  • Page 279 11.1 Error Messages (EXXXX) Error Message Error Code Description E9002 Page length must be 4 lines more than Skip Perforation. The difference of Page Length and Skip Perforation must be more than 4 lines. E9003 Trunk or extension card duplicated. Under Power Failure Transfer, a trunk card or an extension card can be specified only once.
  • Page 280: Warning Messages (Wxxxx)

    11.2 Warning Messages (WXXXX) 11.2 Warning Messages (WXXXX) Message Code Description W0001 Save system data? Some parameters on the screen were changed. A click on "OK" or a screen switch was attempted without saving data. W0002 The status of the port is In-Service (INS). Would you like to continue? When the status of a port is In-Service (INS), and you change some parameters (screens of "1 Configuration"), the port is reset.
  • Page 281 11.2 Warning Messages (WXXXX) Message Code Description W4005 One-Touch dial name must not exceed 10 characters. Truncate it? Truncate means that the leading 10 characters are saved and the rest are deleted. W4006 DDI / DID / TIE additional dial must not exceed 8 digits. Truncate it? Truncate means that the leading 8 digits are saved and the rest are deleted.
  • Page 282 11.2 Warning Messages (WXXXX) Message Code Description W7001 ARS Leading dial must not exceed 10 digits. Truncate it? Truncate means that the leading 10 digits are saved and the rest are deleted. W7002 ARS additional dial must not exceed 20 digits. Truncate it? Truncate means that the leading 20 digits are saved and the rest are deleted.
  • Page 283: Information Message (Ixxxx)

    11.3 Information Message (IXXXX) 11.3 Information Message (IXXXX) Message Code Description I0001 Upload completed. Please change PBX to on-line mode. Uploading the system programming data from PC to PBX is completed. How to change PBX to on-line mode: Set CPU Mode Rotary Switch position to 0. Then, press Reset button.
  • Page 284 11.3 Information Message (IXXXX) Programming Error Messages...
  • Page 285: Default Values

    Section 12 Default Values Default Values...
  • Page 286 1 Configuration 1.1 Configuration 1.2 Slot Assignment Program Default Card Type Blank Status — 1.3 Trunk Port Assignment Program Default Card No. — Group No. 48: E&M card, 1: Others Status — 1.4 Extension Port Assignment Program Default Card No. —...
  • Page 287 Program Default [Ext No.1] DN Blank [Ext No.1] Group No. Blank [Ext No.2] DN Blank [Ext No.2] Group No. Blank Status — 1.6 E1 Port Assignment Program Default Card No. — Channel Type Undefined Group No. Blank Receiver Type Undefined Status —...
  • Page 288 1.9 PRI Port Assignment Program Default Card No. — Type (Display only) Group No. Status — 2 System 2.1 System 2.2 Tenant Program Default Tenant No. Alert Extension Blank DAY / NIGHT Switching Mode Manual Inter-tenant Calling (1 - 8) No check (Auto Start Time) Day 1 (SUN-SAT)
  • Page 289 2.3 Numbering Plan Program Default 1 1st Hundred Block Extension 10: [SP], [NL], [JT], 20: [G] 2 2nd Hundred Block Extension 11: [SP], [NL], [JT], 21: [G] 3 3rd Hundred Block Extension 12: [SP], [NL], [JT], 22: [G] 4 4th Hundred Block Extension 13: [SP], [NL], [JT], 23: [G] 5 5th Hundred Block Extension 14: [SP], [NL], [JT], 24: [G]...
  • Page 290 Program Default 35 Call Park / Call Park Retrieve 36 Account Code 37 Door Open 38 External Feature Access 6: [SP], [NL], [JT], 66: [G] 39 Station Program Clear 40 Message Waiting Set / Cancel / Call Back 41 OGM Playback / Record 36: [SP], [NL], [JT], 712: [G] 42 Call FWD - Do Not Disturb Set / Cancel 43 Dial Call Pickup Deny Set / Cancel...
  • Page 291 Program Default 73 Remote FWD Cancel-Once 74 Trunk Route Control 75 UCD Monitor Mode 76 TIE Line Access 77: [SP], [NL], [JT], Blank: [G] 77-92 Other PBX 01 - Other PBX 16 Blank 93 Paging Deny Set / Cancel 94 Trunk Busy-out 95 Walking Station 96 CLIP / COLP 97 CLIR...
  • Page 292 Program Default Switching Day / Night Mode Disable: [SP], [NL], [JT], Enable: [G] Account Code Mode Optional SDN COS Own Extension Off-Hook Call Announcement (OHCA) Enable Released Link Operation Disable Automatic Hold Disable Charge Management Disable ISDN CFU / CFB / CFNR Disable 2.4.1 Trunk Group Setting Program...
  • Page 293 2.5.2 System Timer 2/2 Program Default Timed Reminder Ringing Time 30 s Call Parking Recall Time 60 s TIE Inter-digit Time DISA Prolong Time 3 min DISA Delayed Answer Time 1 ring Timed Reminder Arrive Count 3 times DISA Automated Attendant Time DISA IRNA Time 60 s Intercept Timer after OGM...
  • Page 294 Program Default 5. Limited call duration Both calls 6. Transfer recall destination Originating extension 7. Checking dial *, # by toll restriction Check 8. Confirmation tone for Override, Barge-in, Enable Conference and Privacy Release 9. Confirmation tone for Call Pickup, Paging- Enable Answer, TAFAS-Answer, Hold Retrieve and Call Park Retrieve...
  • Page 295 Program Default 27. Message Waiting lamp pattern 28. Trunk hunting mode Forced 30. Net CODEC A-law 2.8.4 System Option 4/4 Program Default 31. Answering Call Waiting call by SLT hooking Disable 32. Whisper OHCA to extensions other than T74 / Disable 75XX 33.
  • Page 296 2.9 Language Data 3 Group 3.1 Group 3.2 Trunk Group 3.2.1 Trunk Group - Copy Program Default Group No. Type Public Tenant No. Intercept Destination – Day / Night Blank Line Hunting Order Normal Disconnecting Time 1.5 s: [SP], [NL], [JT], 2.0 s: [G] Pause Time 1.5 s: [SP], [NL], 3.5 s: [JT], [G] Pause Time before Flash Signal...
  • Page 297 3.3 Extension Group 3.3.1 Extension Group - Copy Program Default Group No. Blank Group Type Group No.126: VM, Group No.127: AA, Group No.128: Operator, Others: None Tenant No. [Overflow Setting] Destination – Day / Night Blank [Overflow Setting] Timer None FWD / DND Mode Enable Extension Call Hunting...
  • Page 298 Program Default Mailbox No. Blank [Destinations] DN Blank [Destinations] Ringing Type Immediate 3.6 OGM Group Program Default Group No. Blank Tenant No. OGM Type DISA Security Mode Trunk [DISA built-in Automated Attendant Tables] Dial Blank 0 – Dial 9 4 Line 4.1 Line 4.2 Trunk Line 4.2.1 Trunk Line - Copy...
  • Page 299 Program Default [CPC Signal] OUT Detection Disable (ELCOT card), Enable (E1 [DR2] card) [CPC Signal] OUT Detection - Detection Time 32ms : [SP], None : [NL], [JT], [G] (ELCOT card) [CPC Signal] OUT Detection - Detection Time 160 ms (E1 [DR2] card) [CPC Signal] IN Detection Enable (E1 [DR2], ELCOT card) : [SP], Disable (ELCOT card), Enable (E1 [DR2] card) : [NL], [JT],...
  • Page 300 Program Default Name Blank [COS No.] Primary [COS No.] Secondary Mailbox No. Same as the extension number CO Key CO-01:Loop-CO, Others:Not Stored PF Key Not Stored Initial Display Selection Caller ID Message Lamp [Preferred Line] Outgoing Prime Line - ICM/PDN [Preferred Line] Outgoing - Key No.
  • Page 301 4.3.2 Flexible CO Key Assignment Program Default Key Type CO-01 : Loop-CO, Others : Not Stored 4.3.3 Flexible PF Key Assignment for PT Program Default Key Type Not Stored 4.4 DSS Console 4.4.1 DSS Console - Copy Program Default Paired Extension —...
  • Page 302 Program Default Tenant No. Destination – Day / Night Blank 4.6 External Paging Program Default Pager No. (Display only) Tenant No. Blank No check BGM Source MUS1 4.7 ISDN Extension Line Program Default Card No. — Port. No. Group No. (Display only) Name Blank...
  • Page 303 5 Features 5.1 Features 5.2 System Speed Dialling Program Default Tenant No. Entry No. 000-019 Max. Entry (Display only) Current Registration (Display only) Name Blank Number Blank 5.3 Phantom Extension Program Default Entry No. 001-048 Blank 5.4 Emergency Dial Code Program Default Dial...
  • Page 304 Program Default TRS Level None 5.7 Special Carrier Code Program Default Code Blank 5.8 Absent Message Program Default Message MSG1: Will Return Soon, MSG2: Gone Home, MSG3: At Ext %%%% (Extension No.), MSG4: Back at %% : %% (Hour: Minute), MSG5: Out Until %% / %% (Day / Month): [SP], [NL], [JT], (Month / Day): [G], MSG6: In a Meeting, MSG7-9: Blank 5.9 DISA / TIE User Code...
  • Page 305 Program Default FWD to VM Ringback Tone FWD to VM Busy Tone FWD to Extension Ringback Tone Voice Mail Command Leave Message Get Message AA Service VM Service 5.10.2 VPS Integration 2/2 Program Default DTMF signal duration 80 ms Pause timing before sending DTMF signal 1.5 s (Follow on ID) Pause timing before sending DTMF signal (RBT,...
  • Page 306 5.12 Caller ID Registration Program Default Tenant No. Entry No. 0001-0010 Name Blank Number Blank 5.13 UCD Time Table Program Default Table No. Command Sequence (1-16) Command No.1 of all tables:1T, Others: None 5.14 Charge Program Default Charge Display on LCD Meter Charge by SMDR Meter...
  • Page 307: Toll Restriction

    Program Default Language English 6 Toll Restriction 6.1 Toll Restriction 6.2 TRS Deny Code Program Default TRS Level Entry No. 001-020 Dial Blank: [SP], [NL], [JT], XXXXXXX: [G] (Level 2 only) 6.3 TRS Exception Code Program Default TRS Level Entry No. 001-020 Dial Blank: [SP], [NL], [JT], XXXXXXX: [G] (Level 2...
  • Page 308: Private Network

    Program Default Routing Plan No. None 7.4 Routing Plan Program Default Plan No. [Time-A, -B, -C, -D] Trunk Group No. None [Time-A, -B, -C, -D] Modification Table No. None 7.5 Digits Modification Table Program Default Entry No. 01-08 Digits to delete Number to be added Blank 8 Private Network...
  • Page 309 9 DDI / DID 9.1 DDI / DID 9.2 Number Transformation 9.2.1 Number Transformation Program Default Entry No. 0001-0010 Automatic Registration Please refer to Section "9.2.2 Automatic Registration of DDI / DID / MSN Numbers." DDI / DID / MSN No. Blank Destination –...
  • Page 310 Program Default Disconnection Message (1-5) Message 1: NO CARRIER, Others: Blank 10.4 SMDR Program Default SMDR Connection Output Type Type-A Print out Error Information Disable [Format] Page Length 24 lines [Format] Skip Perforation [Duration Log] Outgoing Calls [Duration Log] Incoming Calls Priority of Caller ID information Number Print out DDI / DID subscriber number...
  • Page 311 Program Default [Password] User Programming 1234 [Password] Walking COS 1234 [Serial Interface Port] PROG (Port 1) [Serial Interface Port] PROG – Parity (Display only) [Serial Interface Port] PROG – NL Code CR+LF [Serial Interface Port] PROG – Word Length (Display only) [Serial Interface Port] PROG –...
  • Page 312 11 Programming Error Messages 11.1 Error Messages (EXXXX) 11.2 Warning Messages (WXXXX) 11.3 Information Message (IXXXX) Default Values...
  • Page 313 Default Values...
  • Page 314 Copyright: This manual is copyrighted by Kyushu Matsushita Electric Co., Ltd. (KME). You may print out this manual solely for internal use with TD500. Except above, you may not reproduce this manual in any form, in whole or part, without the prior written consent of KME. Kyushu Matsushita Electric Co., Ltd.

Table of Contents