4.2 Trunk Line
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
142
[CPC Signal] IN Detection - Detection Time (E1 [DR2] card)
160 ms
1.
None
2.
(1-15)
80 ms
Specifies the expected minimum duration for detecting CPC
(Calling Party Control) signal on incoming CO calls.
Note
• In some countries, the E1 card must not be connected to the
Public Switched Network.
• 1.3 System Features (F/G)
– Calling Party Control (CPC) Signal Detection
Start Signal Type
Wink
1.
Immediate
2.
Wink
Specifies the start signal type for a TIE (E&M) trunk.
1.
Immediate
The system sends the dialling digits to CO after waiting for the
time length determined by "First Dial Timer" in "Card
Properties" screen of the corresponding trunk card.
For information on "Card Properties" screen, please refer to
"Card Type" in Section "1.2 Slot Assignment."
2.
Wink
The system sends the dialling digits to CO after receiving the
wink signal.
• 3.1 E&M Features (F/G)
– E&M (TIE) Line Service
Line