10. Exposure Trays

94MS42 Rev.B1 S/W Ver 2.06
Mylar® Replacement
Close the Mylar® frame and open the twelve cam latches.
Remove the inner Mylar® frame and position a pre-cut Mylar® sheet
into the frame. Make sure that the Mylar® is overlapping on all sides.
Reinstall the inner Mylar® frame and ensure all cam latches are closed.
Trim the excess Mylar® from between the inner and outer frames.
If Mylar® Pulls Out of the Frame.
Make sure the Mylar® is not cut too small. The Mylar® must overlap
on all sides so that it comes up between the inner and outer frames. Mark
on the Mylar® where the cam latches are and cut a small slit in the mylar
to allow the cam latches to lock down. Then trimmed off once the inner
frame has all the cam latches in the closed position.
Make sure the inner and outer frames are not bent or damaged, if so,
replace them.

Outer Frame Replacement

Remove the inner frame.
Open the frame then remove the safety clips from the gas shocks.
While holding the frame up pull the gas shocks off of the mounting ball
joints then lower the frame.
Remove the 2 Allen screws from each of the four hinges in the back of
the frame and lift the frame off.
Note: The frame MUST be squared when it is reinstalled.
Closed
Position
Open
Position
Cam Latch
10-1