10. Exposure Trays; Mylar® Replacement; If Mylar® Pulls Out Of The Frame; Outer Frame Replacement - Accuprint AP30CL - 6000 Service Manual

Closed loop cooling high resolution printer
Table of Contents

Advertisement

10. Exposure Trays

94MS41 Rev. C1 S/W Ver 2.06
Mylar® Replacement
Close the Mylar® frame and open the six cam latches.
Remove the inner Mylar® frame and position the pre-cut Mylar® sheet
into the frame, make sure that the Mylar® is overlapping on all side.
Reinstall the inner Mylar® frame and ensure all cam latches are closed.
Trim the excess Mylar® from between the inner and outer frames.
If Mylar® Pulls Out of the Frame
Make sure the Mylar® is not cut to small. The Mylar® must overlap on
all sides so that it comes up between the inner and outer frames and then
trimmed off once the inner frame has all the cam latches in the closed
position.
Make sure the inner and outer frames are not bent or damaged if they are
replace them.

Outer Frame Replacement

Remove the inner frame.
Open the frame then remove the safety clips from the gas shocks.
While holding the frame up pull the gas shocks off of the mounting ball
joints then lower the frame.
Remove the 3 Allen screws from each of the two hinges in the back of
the frame and lift the frame off.
Note: The frame MUST be aligned when it is reinstalled.
Place the new frame flat on the tray, line up and insert the Allen head
Closed
Position
Open
Position
Cam Latch