Low
Medium
High
STOP
GO
Front right arm of
operator control panel
94MS42 Rev. B1 S/W Ver. 2.06
Setting the Light Intensity
Press the I key to set intensity. Press I for the first time. The first
•
LED on the left indicates the intensity is set to low 2kW.
Press: I for the second time. The first two LEDs light to indicate the
•
intensity is set to medium 4kW.
Press: I key for the third time. All three LEDs light to indicate the
•
intensity is set to high 8kW.
Press the T key to set for time or integrate mode. The
Optional:
LED ON indicates a timed exposure and OFF an integrated exposure.
Note: During operation, ensure that the T mode is OFF.
Making an exposure
Place material in the exposure frame and close the frame.
If [ F rCL] and [ A UAC] options are turned ON, vacuum will start automatically
•
when the frame is closed. If [ F rCL] and [ A UAC] are OFF, press the G
button to start vacuum. The upper or lower vacuum gauge will indicate
the vacuum level for the appropriate frame.
•
Examine both sides of the frame to check the vacuum drawdown visually.
When good vacuum contact is assured, press the G button to move the
•
frame into the cabinet and start exposure. If second frame has been
examined press the G button and the frame will go into the cabinet
(The frames will not move if the previous exposure is still in progress.)
•
Remove the material from the frame that was previously exposed and
repeat for the next exposure.
To stop the frame after it has started moving, press the S button once.
•
To retrieve it, press S again, or to continue with the exposure, press
the G button. The frame will move in at a slower speed.
Blank frame cycle
To change frame position with no vacuum or exposure:
Note: If [ F rCL] is turned ON and you do not open the frame, press the
G button and the frame will move in without vacuum or
exposure.
Press and hold the S button.
•
Press the G button.
•
•
Release both buttons when the frames start moving
4-11