Auto Step Mode; Set Default Vacuum Delay - Accuprint AP42CL 8000 Service Manual

Closed loop high resolution printer
Table of Contents

Advertisement

[ A UAC]
[ S EL_]
[ A StP]
[ S EL_]
[ d UAC]
94MS42 Rev. B1 S/W Ver. 2.06
Press and release the e key until [ A UAC] appears in the Exposure window.
This places you in the automatic vacuum option.
Press the V key to cycle the automatic vacuum mode ON or OFF.
Press the 0 key twice to exit this mode.

Auto Step Mode

Note: This feature allows you to run a series of exposures in sequence.
Note: If Auto Step is selected, the LED over the U key will indicate if
the feature is ON or OFF. If ON, press the V key to turn it OFF.
Press the P key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
Press 1,2,3t 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in the select mode.
Press the Y key once. The Memory window will read [ S u] .
Press and release the e key until [ A StP] appears in the Exposure window.
This places you in the autostep option.
Press the V key to cycle the Auto-Step mode ON or OFF.
Press the 0 key twice to exit this mode.

Set Default Vacuum Delay

Note: This feature is used to provide sufficient vacuum drawdown time
before exposure. The time begins when the frame lid is closed
with the [ A UAC] turned ON, or when you press the G button for
the first time. If you press the G button again before the vacuum
delay counts down, the frame will move into the cabinet, but the
exposure will not start until the time is completed.
Note: This default delay time will be ignored if a delay time other than
0 has been programed into the memory location being displayed.
Press the P key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
Press 1,2,3t 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in the select mode.
Press the Y key once. The Memory window will read [ S u] .
Press and release the e key until the Exposure window reads [ d UAC] .
Press the V key and enter the time you wish the vacuum turned ON
before the exposure begins. The time you selected has now been
programed for all memories.
Press the 0 key twice to exit this mode.
4-7