Operator Control Panel - Accuprint AP42CL 8000 Service Manual

Closed loop high resolution printer
Table of Contents

Advertisement

P
S
G
3-4

Operator Control Panel

The AP 30 heavy duty exposure system has a power key on the integrator.
Press the P key to turn on the unit.
Press the P key again after use, and the system will run through a 2
minute cool down cycle and then turn off all blowers.
STOP Button
Press the S button once. Frame movement will stop.
Press the S button once more, the frame will return, at slow speed, to
the original position and vacuum will turn off.
Press the S button twice to cancel an exposure.
Holding the S button down then pressing the G button starts a blank
cycle - no vacuum or exposure.
GO Button
Press the G button once to initiate vacuum drawdown on the exposure
frame.
Press the G button a second time to move the frame into the unit and
start an exposure.
If frame switch [ F rCl] and auto vacuum [ A UAC] are turned on, press the
G button once to move the frame into the unit and start an exposure.
If frame switch [ F rCl] and auto vac [ A UAC] are turned on, press the G
button once without opening the upper or lower frame will start a blank
frame cycle - no vacuum or exposure.
Note: If a vacuum delay [ d UAC] is used, the exposure will not begin
until the vacuum delay time has counted down.
Table Showing the 12 Calibration Positions
[ U t]
Upper Frame, Top Surface
[ U b]
Upper Frame, Bottom Surface
[ L t]
Lower Frame, Top Surface
[ L b]
Lower Frame, Bottom Surface
1st
5th
2nd
6th
3rd
7th
4th
8th
94MS42 Rev. B1 S/W Ver. 2.06
9th
10th
11th
12th

Advertisement

Table of Contents
loading

Table of Contents