Input Diagnostics; Typical Values That You Will See When All Switches Are Good - Accuprint AP42CL 8000 Service Manual

Closed loop high resolution printer
Table of Contents

Advertisement

[ S EL_]
[ 0 037]
[ 0 165]
[ 0 053]
94MS42 Rev. B1 S/W Ver. 2.06

Input Diagnostics

Switch Check
The switch check can be done while in the Select mode.
Press the P key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
Press 1,2,3, then 4 in sequence. The Vacuum window will read
[ S EL_] . This places you in select mode.
Press the 6 key. The Exposure window on the integrator will show
various numbers as the switches or keys are closed.
Examples:
With the upper frame moved in, the side access door
switches closed, and the G key pressed on the nose section,
the lower integrator display should read [ 0 165] . With the lower
frame in, the display should read [ 0 172] .
G
DOOR
128
+32
128
+32
Switch Table
Switch Value
1
4
8
16
32
128

Typical values that you will see when all switches are good.

Upper tray in, Frame switch closed, Door and Emergency switches closed.
The bottom display should read [ 0 037] .
When the G button is pushed the value should change to [ 0 165] .
When the S button is pushed the value should change to [ 0 053] .
FRAME SWITCH FRAME
+4
+1
+4
+8
Function
Upper frame in (labeled "frame")
Frame switch
Lower frame in (labeled "frame")
S key, nose section
Door/emergency z switch
G key, nose section
NUMBER DISPLAYED
= [ 0 165] (Upper Frame In)
= [ 0 172] (Lower Frame In)
5-3

Advertisement

Table of Contents
loading