Accuprint AP42CL 8000 Service Manual page 46

Closed loop high resolution printer
Table of Contents

Advertisement

6-2
reflectors and glass can substantially reduce light output.
Wear the white lightweight fabric gloves that are provided and unpack
the new lamp. Clean the lamp with the alcohol wipe included.
Place each end of the new OLITE lamp (one end at a time) on the holders.
DO NOT touch the lamp with your hands. Contamination of the quartz
tube of the lamp with skin oils will shorten the life considerably and may
lead to failure.
Reconnect the lamp by fully inserting the spade lugs on the connecting
wires under BOTH thumbscrews and tighten. Ensure the wires are
positioned so they do not touch the lamp body or the reflector and cooling
tube.
Insert the safety glass into the holders and push against the housing.
Ensure the safety interlock lever is positioned firmly underneath the glass
towards the lamp and not squeezed to the side. Also, ensure the safety
glass is loose enough to allow for heat expansion during an exposure.
The light will not operate unless the safety glass is installed properly.
When the safety glass is properly installed, it will be able to move slightly.
If the safety glass is installed too tight, it may be damaged during use.
Note: OLITE Lamps are specifically designed for OLEC and undergo
careful testing and preperation before shipment. They carry the
OLEC Warranty of Satisfaction. Substitutes and copies of lamps
are not approved by OLEC, nor do they carry our Warranty. Use
approved OLEC replacement parts ONLY!
94MS42 Rev. B1 S/W Ver 2.06