Hybrid Station Modular Jack Wiring; Dkt/Slt Station Modular Jack Wiring - iPECS eMG80 Installation Manual

Hide thumbs Also See for eMG80:
Table of Contents

Advertisement

iPECS eMG80
Hardware Description and Installation Manual

6.4.5 Hybrid Station Modular Jack Wiring

Hybrid Station modular jacks are terminated with one Digital and one SLT circuit to an
RJ11 jack as shown in the chart below. For the Hybrid ports only one of the station circuits,
DKT or SLT, can be used. To wire the Hybrid Station modular jack,
1. Wire each Hybrid Station modular jack to the termination point.
2. Tag the wiring for future maintenance.
Connector
RJ11

6.4.6 DKT/SLT Station Modular Jack Wiring

The last four (4) MBUAD and MBUID built-in Station ports provide both a Digital and SLT
port. These Station modular jacks are terminated with one Digital and one SLT circuit to an
RJ11 jack as shown in the chart below. Both the DKT and SLT interface ports can be wired
and used simultaneously. To wire these 'combo' Station modular jacks,
1. Wire each combo Station modular jack to the termination point.
2. Tag the wiring for future maintenance.
Connector
RJ11
Table 6.4.5-1 Hybrid Station Modular Jack Wiring
Pin-out
Table 6.4.6-1 DKT/SLT Station Modular Jack Wiring
Pin-out
Pin Number
Signal Name
1
N/A
2
DKT-T
3,4
SLT-T, SLT-R
5
DKT-R
6
N/A
Pin Number
Signal Name
1
N/A
2
DKT-T
3,4
SLT-T, SLT-R
5
DKT-R
6
N/A
70
Issue 1.0