iPECS eMG80 Installation Manual
Hide thumbs Also See for eMG80:
Table of Contents

Advertisement

iPECS eMG80
Hardware Description & Installation
Manual
Please read this manual carefully before operating System.
Retain it for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for iPECS eMG80

  • Page 1 Hardware Description & Installation Manual Please read this manual carefully before operating System. Retain it for future reference.
  • Page 2: Regulatory Information

    Issue 1.0 Regulatory Information Before connecting the iPECS eMG80 to the telephone network, you may be required to notify your local serving telephone company of your intention to use "customer provided equipment". You may further be required to provide any or all of the following information:...
  • Page 3 Hardware Description and Installation Manual Issue 1.0 The use of this device in a system operating either partially or completely outdoors may require the user to obtain a license for the system according to the Canadian regulations. For further information contact your Local Industry Canada office.
  • Page 4: Revision History

    If you are not the intended recipient, you should destroy or retrieve this material to Ericsson-LG. iPECS is trademark of Ericsson-LG Co., Ltd. All other brand and product names are trademarks or registered trademarks of their respective...
  • Page 5: Table Of Contents

    Safety Requirements ..................1 1.1.2 Precaution ......................2 About This Manual ..................3 2. SYSTEM OVERVIEW ................4 iPECS eMG80 System Highlights ............... 4 General Cabinet Description ............... 4 System Connection Diagram ..............6 System Components ................... 7 Specifications ....................9 2.5.1...
  • Page 6: Mounting The Ksu And Eksu

    Hardware Description and Installation Manual Issue 1.0 4.7.1 CH204 (2 CO Line and 4 Hybrid Interface Board) ..........41 4.7.2 CH408 (4 CO Line and 8 Hybrid Interface Board) ..........42 4.7.3 CS416 (4 CO and 16 SLT Interface Board) ............. 43 4.7.4...
  • Page 7 LDP-7000 and LDP-9000 series Wall Mount ........... 88 7.4.2 LIP-8000E Wall Mount ..................89 8. STARTING THE IPECS EMG80 ............90 iPECS eMG80 System Initial Power-up ............ 90 Verify the Nation Code ................91 8.2.1 Using the DKT ....................91 Installation Wizard ..................92 9.
  • Page 8: Introduction

    Hardware Description and Installation Manual Issue 1.0 1. I NTRODUCTION 1.1 Important Safety Instructions 1.1.1 Safety Requirements  When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and other personal injury, including the following: ...
  • Page 9: Precaution

    Keep the system away from heating appliances and electrical noise generating devices such as florescent lamps, motors and televisions. These noise sources can interfere with the performance of the iPECS eMG80 System.  This system should be kept free of dust, moisture, high temperature (more than 40 degrees) and vibration, and should not be exposed to direct sunlight.
  • Page 10: About This Manual

    1.2 About This Manual This document provides general information covering the description and installation of the iPECS eMG80 System hardware. While every effort has been taken to ensure the accuracy of this information, Ericsson-LG makes no warranty of accuracy or interpretations thereof.
  • Page 11: System Overview

    8 to more than 100 phones that is easy to install, manage and use. The eMG80 interfaces with analog CO lines, digital and ISDN lines, and SIP trunks. For flexibility and ease of use, an array of user terminals are available including proprietary digital and IP multi-button phones, as well as standard SLTs and SIP phones.
  • Page 12 Hardware Description and Installation Manual Issue 1.0 Figure 2.2-1 KSU Appearance Figure 2.2-2 EKSU Appearance...
  • Page 13: System Connection Diagram

    Hardware Description and Installation Manual Issue 1.0 2.3 System Connection Diagram The following figure represents the interconnections available with the iPECS eMG80 including external network, terminals, miscellaneous, and admin interfaces. Figure 2.2-3 System Connection Diagram...
  • Page 14: System Components

    Function boards. The specific MBU determines the type of external network and terminal interfaces, and the optional Interface boards that can be installed in an eMG80 KSU. The table 2.4-1 below shows all available components for an eMG80 KSU including the various MBUs, and optional Interface and Function boards.
  • Page 15 Hardware Description and Installation Manual Issue 1.0 Table 2.4-2 Option Board Compatibility Chart for KSU Option Board KSUA KSUAD KSUI KSUID EKSU Interface Boards eMG80-CH204 eMG80-CH408 eMG80-CS416 eMG80-BH104 eMG80-BH208 eMG80-PRIU eMG80-BRIU2 eMG80-HYB8 eMG80-SLB16 eMG80-WTIB4 Function Boards eMG80-VVMU eMG80-MEMU...
  • Page 16: Specifications

    Hardware Description and Installation Manual Issue 1.0 2.5 Specifications 2.5.1 General Specifications Table 2.5.1-1 General Specifications Item Description Specification M83261G, ARM11 dual core (32bit, 650MHz) RTC Back-up Battery 7 years Duration AC Voltage Input 100~240 +/- 10% Volt AC @ 47-63 Hz...
  • Page 17: System Capacity

    Hardware Description and Installation Manual Issue 1.0 2.5.2 System Capacity Three System Capacity charts are provided below. These include the General System Maximum Capacities Table 2.5.2-1, the capacity based on the MBU type Table 2.5.2-2 to Table 2.5.2-5. Note that the maximums are not simultaneously achievable. However, the maximum number of VoIP channels is separate from other external network and station maximums.
  • Page 18 Hardware Description and Installation Manual Issue 1.0 Item Capacity Save Number Redial 1 number of 23 digits Call Log(Outgoing/Incoming/Missed 15 ~ 50, 23 digits (programmable) Call) DSS Consoles per Station SMDR buffer 5000 CO Line Groups Station & Hunt Groups Station &...
  • Page 19 Hardware Description and Installation Manual Issue 1.0 Table 2.5.2-2 KSUA Device Type Maximums Resource Device Type Maximum Capacity Interface Boards Type KSUA: 4 CO & 1 DKT + 7 Hybrid & 2VoIP CO Line 2 CH408 or 1 CH408 + 1 CS416 BRI Line 4 (2B+D) &...
  • Page 20 Hardware Description and Installation Manual Issue 1.0 Table 2.5.2-3 KSUAD Device Type Maximums Resource Device Maximum Capacity Interface Boards Type KSUAD: 4 CO & 8 DKT+4 SLT & 2 VoIP CO Line 2 CH408 or 1 CH408 + 1 CS416 BRI Line 4 (2B+D) &...
  • Page 21 Hardware Description and Installation Manual Issue 1.0 Table 2.5.2-4 KSUI Device Type Maximums Resource Device Maximum Capacity Interface Boards Type KSUI: 0 CO & 1 DKT + 7 Hybrid & 2 VoIP CO Line 2 CH408 or 1 CH408 + 1 CS416...
  • Page 22 Hardware Description and Installation Manual Issue 1.0 Table 2.5.2-5 KSUID Device Type Maximums Resource Device Maximum Capacity Interface Boards Type KSUID: 0 CO & 8 DKT + 4 SLT & 2 VoIP CO Line 2 CH408 or 1 CH408 + 1 CS416...
  • Page 23: Base Station Specification (Gdc-600Be)

    Hardware Description and Installation Manual Issue 1.0 2.5.3 Base station specification (GDC-600BE) Table 2.5.3-1 DECT Base Station Specifications Item Specification Power feeding +30VDC Transmission Max Power 250mW Access Method/Duplex TDMA/TDD 1,880 ~ 1,900MHz Frequency Band 1920~1930MHz (USA) Channel Spacing 1.728MHz...
  • Page 24: Installation Overview

    Anti-static precautions should be taken during installation. 3.1.2 Installation precautions The iPECS eMG80 KSUs are designed for desktop mounting, wall mounting or a free- standing rack mounting. In no case should one cabinet be mounted on top of the other when desktop mounting.
  • Page 25: Wiring Precautions

     The power and battery switches must be OFF during wiring. Further, while wiring, power must not be connected to the eMG80 KSU. After wiring is completed, the power can be connected and the switch may be turned ON. ...
  • Page 26 Hardware Description and Installation Manual Issue 1.0 Figure 3-1 KSU Carton Contents...
  • Page 27 Hardware Description and Installation Manual Issue 1.0 Figure 3-2 EKSU Carton Contents...
  • Page 28: Board Installation And Description

    OARD INSTALLATION AND DESCRIPTION 4.1 General information The eMG80 KSU houses the Main Board with processor, memory and interface circuitry. Optional Interface boards are installed on the MBU to expand the external network interfaces as well as terminals available. Both the KSU and Expansion KSUs can be equipped with two (2) optional Interface boards.
  • Page 29 Hardware Description and Installation Manual Issue 1.0 Closing the Front Cover 1. Insert the front cover into the slot on the KSU correctly. 2. Then put the front cover down on the KSU in the direction of the arrow.
  • Page 30: Removing And Replacing The Ksu & Cord Cover

    Figure 4.3 Opening the Front Cover NOTE For safety, prior to operation, replace the KSU and Cord cover before operating the eMG80. Regarding attaching the cord cover, refer to the section 6.9.3. To replace the front cover, basically reverse the removal procedure as below.
  • Page 31: Installation Of Option Boards

    Hardware Description and Installation Manual Issue 1.0 4.4 Installation of Option Boards Prior to installing any option board, assure power is OFF. We recommend wearing a wrist- strap connected to a known ground. At a minimum, before touching any board discharge any built-up static charge by touching a grounded object.
  • Page 32: Ksu Main Board Unit (Mbu)

    The MBUA contains switches for database protection and initialization. A built-in LAN port provides access to the eMG80 Web Admin and basic VoIP channels. In addition, a USB port is provided to allow backup and restore of the system database.
  • Page 33 Hardware Description and Installation Manual Issue 1.0 Figure 4.5.1-1 MBUA The following are included on the MBUA: 4 CO Line interface circuits  1 DKT (Digital Key Telephone) interface circuit for Attendant station 100  7 Hybrid (DKT or SLT) interface circuits ...
  • Page 34 Hardware Description and Installation Manual Issue 1.0 Connectors, Jacks and Switches The following chart lists the various connectors for option boards, RJ modular jacks for connecting CO Lines, Stations and miscellaneous functions, and switches on the Main Board.
  • Page 35: Mbuad (Main Board Unit)

    PCM signal, generates the System tones, and manages System call processing. The MBUAD contains switches for database protection and initialization. A built-in LAN port provides access to the eMG80 Web Admin and basic VoIP channels. In addition, a USB port is provided to allow backup and restore of the system database.
  • Page 36 Hardware Description and Installation Manual Issue 1.0 Figure 4.5.2-1 MBUAD The following are included on the MBUAD: 4 CO Line interface circuits  8 DKT interface circuits  4 SLT interface circuits  1 External Relay contact for LBC or general purpose ...
  • Page 37 Hardware Description and Installation Manual Issue 1.0 Connectors, Jacks and Switches The following chart lists the various connectors for option boards, RJ modular jacks for connecting CO Lines, Stations and miscellaneous functions, and switches on the Main Board.
  • Page 38: Mbui (Main Board Unit)

    PCM signal, generates the System tones, and manages System call processing. The MBUI contains switches for database protection and initialization. A built-in LAN port provides access to the eMG80 Web Admin. In addition, a USB port is provided to allow backup and restore of the system database.
  • Page 39 Hardware Description and Installation Manual Issue 1.0 Figure 4.5.3-1 MBUI The following are included on the MBUI: 1 DKT interface circuit  7 Hybrid (DKT or SLT) interface circuits  PRIU or BRIU2 interface connector  1 External Relay contact for LBC or general purpose ...
  • Page 40 Hardware Description and Installation Manual Issue 1.0 Connectors, Jacks and Switches The following chart lists the various connectors for option boards, RJ modular jacks for connecting CO Lines, Stations and miscellaneous functions, and switches on the Main Board.
  • Page 41: Mbuid (Main Board Unit)

    PCM signal, generates the System tones, and manages System call processing. The MBUID contains switches for database protection and initialization. A built-in LAN port provides access to the eMG80 Web Admin and basic VoIP channels. In addition, a USB port is provided to allow backup and restore of the system database.
  • Page 42 Hardware Description and Installation Manual Issue 1.0 Figure 4.5.4-1 MBUID The following are included on the MBUID: 8 DKT interface circuits  4 SLT interface circuits  PRIU or BRIU2 interface connector  1 External Relay contact for LBC or general purpose ...
  • Page 43 Hardware Description and Installation Manual Issue 1.0 Connectors, Jacks and Switches The following chart lists the various connectors for option boards, RJ modular jacks for connecting CO Lines, Stations and miscellaneous functions, and switches on the Main Board.
  • Page 44: Eksu Expansion Main Board Unit (Embu)

    Hardware Description and Installation Manual Issue 1.0 4.6 EKSU Expansion Main Board Unit (EMBU) Description The EKSU houses the EMBU, which is shown in figure 4.6-1 and controls communication between the EKSU and the installed optional Interface boards and the KSU that controls the interfaces.
  • Page 45 Hardware Description and Installation Manual Issue 1.0 Figure 4.6-1 EMBU The following are included on the EMBU: 4 CO Line interface circuits  8 Hybrid interface circuits  1 External Relay contact for LBC or general purpose ...
  • Page 46 Hardware Description and Installation Manual Issue 1.0 Connectors, Jacks and Switches The following chart lists the various connectors for option boards, RJ modular jacks for connecting CO Lines, Stations and miscellaneous functions, and switches on the Main Board.
  • Page 47: Optional Interface Boards

    Optional Interface Boards permit the expansion of the external network and terminal interface ports available in the eMG80 system are mounted on the Main board in the KSU or EKSU. Interface boards available are shown in the chart below. Note that the boards that can be installed in a KSU are dependent on the type of Main Board as discussed in section 4.5.
  • Page 48: Ch204 (2 Co Line And 4 Hybrid Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.1 CH204 (2 CO Line and 4 Hybrid Interface Board) Description The CH204 board has two (2) CO line and four (4) Hybrid (DKT & SLT) interface ports. The board may be installed on the CN1 connector of the KSU or EKSU. The MG-CMU4 daughter board may be mounted on the CH204 to provide Call Metering.
  • Page 49: Ch408 (4 Co Line And 8 Hybrid Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.2 CH408 (4 CO Line and 8 Hybrid Interface Board) Description The CH408 board has four (4) CO line and eight (8) Hybrid (DKT & SLT) interface ports. The board can be installed on the CN1 connector of the KSU or EKSU. Also, the MG-...
  • Page 50: Cs416 (4 Co And 16 Slt Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.3 CS416 (4 CO and 16 SLT Interface Board) Description The CS416 board has four (4) CO line and 16 SLT interface ports. Note that eight of the 16 SLT interface ports are provided from the SLU8 daughter board that is factory installed.
  • Page 51: Bh104 (1Bri And 4 Hybrid Interface Board)

    Hardware Description and Installation Manual Issue 1.0 LED Indications Table 4.7.3-2 CS416 LED Indications Color Description Blue Station port in use status ON – A station port is in use OFF – All station ports are idle 4.7.4 BH104 (1BRI and 4 Hybrid Interface Board) Description The BH104 board has one (1) BRI (2B+D) and 4 Hybrid (DKT &...
  • Page 52 Hardware Description and Installation Manual Issue 1.0 Switch setting Table 4.7.4-2 BH104 BRI Mode SW1 Mode Pole Function Remarks S or T mode S mode T mode 2 & 3 Reserved Default=OFF BRI line loopback Test Table 4.7.4-3 BH104 BRI Termination SW200...
  • Page 53: Bh208 (2Bri And 8 Hybrid Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.5 BH208 (2BRI and 8 Hybrid Interface Board) Description The BH208 board has two (2) BRI (2B+D) and 8 Hybrid (DKT & SLT) interface ports. The board, as shown in Figure 4.7.5-1, can be installed on the CN1 connector of only the KSU.
  • Page 54: Priu (1 Pri -30 Channels- Interface Board)

    Hardware Description and Installation Manual Issue 1.0 Table 4.7.5-3 BH208 BRI Termination SW200 Pole Function Termination Remarks Port 1 Termination Resistor Termination 1 & 2 ON = Terminate Resistor OFF = Open Default = ON Port 2 Termination Resistor Termination 3 &...
  • Page 55 Hardware Description and Installation Manual Issue 1.0 Figure 4.7.6-1 PRIU Connector and Modular jack Table 4.7.6-1 Connector and Modular Jack Function Connector Functions Remark Connection for CN2 MBUI or MBUID 40 Pins PRI, E1R2 line RJ45 Switch setting Table 4.7.6-2 PRIU PRI/E1 Function SW1...
  • Page 56: Briu2 (2 Bri -4 Channels- Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.7 BRIU2 (2 BRI -4 Channels- Interface Board) Description The BRIU2 board has two (2) BRI (2B+D) interface ports. The board, as shown in Figure 4.7.7-1, can be installed only on the CN2 connector of either an MBUI or MBUID.
  • Page 57 Hardware Description and Installation Manual Issue 1.0 Table 4.7.7-3 BRIU2 BRI Termination SW2 Pole Function Termination Remarks BRI 1 Termination Resistor Termination 1 & 2 ON = Terminate Resistor OFF = Open Default = ON BRI 2 Termination Resistor Termination 3 &...
  • Page 58: Hyb8 (Hybrid 8 Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.8 HYB8 (Hybrid 8 Interface Board) Description The HYB8 board is shown in Figure 4.7.8-1 and has 8 Hybrid (DKT & SLT) interface circuits. The board can be installed on the CN1 connector of a KSU or EKSU for expansion.
  • Page 59: Slb16 (Slt 16 Interface Board)

    Hardware Description and Installation Manual Issue 1.0 4.7.9 SLB16 (SLT 16 Interface Board) Description The SLB16 board is shown in Figure 4.7.9-1 and has 16 SLT interface circuits. Note that eight of the 16 SLT interface ports are provided from the SLU8 daughter that is factory installed.
  • Page 60: Wtib4 Wireless Dect Interface Board

    Figure 4.7.10-1, has four (4) interfaces to GDC 600BE multi-channel DECT Base Stations. Only one WTIB4 may be installed in the KSU of an eMG80 system. As access to the WTIB4 board may be required during installation of the Base Stations, we recommend installing the WTIB4 as the second Interface board on the KSU CN1 connector.
  • Page 61 Hardware Description and Installation Manual Issue 1.0 Switch setting Table 4.7.10-2 WTIB4 SW1 Switch Function Remark Reset Button Push button Table 4.7.10-3 SW2 - DIP Switch Pole Functions Default Operation TBR6 mode Normal service mode Echo canceller Control...
  • Page 62: Optional Function Boards

    VVMU expands the number of VoIP channels by eight (8) for a maximum total of 16 VoIP channels. For Voice Mail, the basic eMG80 is equipped with two (2) channels and 1 hour of storage. The eMG80 can support an additional two (2) Voice Mail channels with an unlock code.
  • Page 63 Hardware Description and Installation Manual Issue 1.0 Figure 4.8.1-1 VVMU Connector and Modular jack Table 4.8.1-2 Connector and Modular Jack Function Connector Functions Remark Connection to CN3 of the MBU 32 Pins CPLD JTAG for development 10 Pins...
  • Page 64: Memu (Memory Expansion Module Unit)

    The MEMU is equipped with Nand Flash memory used to expand the storage capacity of the eMG80 Voice Mail by 15 hours. As with the basic and VVMU storage, the MEMU storage is non-volatile and any messages are stored with MBU SW1 condition (pole #2 –...
  • Page 65: Modu (Modem Function Unit)

    Hardware Description and Installation Manual Issue 1.0 4.8.3 MODU (Modem Function Unit) Description The MODU, which is shown in Figure 4.8.3-1 below, provides an analog modem interface supporting Bell, ITU-T, V.34, V.32BIS and V.90 protocols at baud rates of 300bps up to 33Kbps with automatic rate negotiation.
  • Page 66: Mounting The Ksu And Eksu

    Hardware Description and Installation Manual Issue 1.0 5. M OUNTING THE KSU AND EKSU Once all option boards have been installed in the KSU and EKSU, the KSUs can be mounted. The KSUs can be desk, wall or rack mounted. While the KSUs may be desk mounted this is general not recommended and Wall and Rack mount provide added safety and optimal operation environment.
  • Page 67: Desk Mount

    Hardware Description and Installation Manual Issue 1.0 5.2 Desk Mount Although not recommended, the KSU can be mounted on a desk, shelf or table-top. In this case assure the EKSU and KSU are located side by side with a minimum of 5 cm separation.
  • Page 68: Wall Mount

    Hardware Description and Installation Manual Issue 1.0 5.3 Wall Mount Wall Mounting is the common installation method as shown in figure 5.3-1. It is recommended that a backboard such as a ¾ inch sheet of plywood be installed and securely fixed to the wall for mounting of the KSUs, terminal blocks and other miscellaneous equipment.
  • Page 69: Rack Mount

    Issue 1.0 5.4 Rack Mount The eMG80 can be mounted on a standard 19-inch rack employing the Rack brackets. Before mounting in the rack, assure that ventilation, space, power and grounding are sufficient. Figure 5.4-1 depicts rack mounting, use the figure and the steps below to rack mount the KSUs.
  • Page 70 Hardware Description and Installation Manual Issue 1.0 EKSU Figure 5.4-1 Installing Rack Bracket and Rack Mount...
  • Page 71: Ksu And Eksu Wiring

    Hardware Description and Installation Manual Issue 1.0 6. K SU AND EKSU WIRING 6.1 Connecting the Basic and Expansion KSUs If an Expansion KSU is installed, it must be connected to the KSU for command and control. The EKSU must be connected to the KSU employing the Expansion cabling as shown in figure 6.1-1.
  • Page 72: Grounding The Ksus

    Issue 1.0 6.2 Grounding the KSUs Proper connection of the eMG80 KSUs to earth ground is very important to prevent user contact with dangerous voltages and reduce electrical and RF interference. Assure that both the KSU and EKSU are properly grounded as described below and shown in figure 6.2-1.
  • Page 73: External Backup Battery Installation

    In case of power failure, the external backup batteries automatically maintain uninterrupted power to the iPECS eMG80 System. The external batteries must provide 24V DC; this is generally accomplished by connecting two 12V batteries in a series arrangement as shown in figure 6.3-1.
  • Page 74 It is recommended to use an external backup battery fuse (10A@250V) between the battery and the System.  Recommended battery capacity is 24V/20AH MF; the iPECS eMG80 System should be able to operate more than 3 hours with batteries that are in good condition. ...
  • Page 75: Line And Station Modular Jack Wiring

    Hardware Description and Installation Manual Issue 1.0 6.4 Line and Station Modular Jack Wiring The MBU and Interface boards determine the type and number of external network and Station connections available. Section 4 provides details on each MBU and Interface boards.
  • Page 76: Pri Line Modular Jack Wiring

    Hardware Description and Installation Manual Issue 1.0 6.4.3 PRI Line Modular Jack Wiring The PRI Line modular jack is terminated with one PRI line circuit to an RJ45 jack as shown in the chart below. To wire the PRI Line modular jack, 1.
  • Page 77: Hybrid Station Modular Jack Wiring

    Hardware Description and Installation Manual Issue 1.0 6.4.5 Hybrid Station Modular Jack Wiring Hybrid Station modular jacks are terminated with one Digital and one SLT circuit to an RJ11 jack as shown in the chart below. For the Hybrid ports only one of the station circuits, DKT or SLT, can be used.
  • Page 78: Slt Station Modular Jack Wiring

    After completing installation and initial power-up of the eMG80 system, the DECT Base Stations can be located and installed as directed in the DECT Installation manual, GDC-600TBE (CRS tool) user manual. After installing the Base Stations, the DECT handsets can be subscribed to the Base Stations and registered to the system.
  • Page 79 Hardware Description and Installation Manual Issue 1.0 Figure 6.4.8-1 WTIB4 Wiring with Ferrite Core CAUTION All wiring between the WTIB4 and the GDC-600BE Base Station must use twisted pair cable, use either Cat 3 or Cat 5 cabling. Use of untwisted pair wiring, even in short lengths will cause faulty operation of the Base Station and the DECT handsets.
  • Page 80 Changing the Dip switch positions during the test will not affect the Automatic Line Test. After the test is complete, place the DIP switches in the proper position, refer to section 0, then press the WTIB4 reset button or reset the eMG80 system.
  • Page 81: Mbu And Vvmu Lan Port Wiring

    Hardware Description and Installation Manual Issue 1.0 6.5 MBU and VVMU LAN Port Wiring The MBU and VVMU incorporate an IEEE 802.3 10/100 Base-T LAN port. The LAN port is terminated in a RJ45 connector with the standard MDI terminations as shown in the chart below.
  • Page 82: Connecting Miscellaneous Devices

    Hardware Description and Installation Manual Issue 1.0 6.7 Connecting Miscellaneous Devices The KUS MBU provides connections for an external music source, external page port, relay contact, and alarm detection input monitor. The EKSU EMBU provides additional connections for a second relay contact output and alarm detection input. In both cases, an RJ45 jack is used to terminate the interfaces as shown in figure 6.7-1 below and the wiring charts.
  • Page 83 Hardware Description and Installation Manual Issue 1.0 Figure 6.7-1 Miscellaneous Connections Modular Jack Pin Assignment Table 6.7-1 KSU Miscellaneous Connector MJ4 Wiring Connector Pin-out Pin Number Signal Name Function RELAY_T Relay Contact Tip RELAY_R Relay Contact Ring ALARM_T...
  • Page 84: Serial Port Wiring

    Hardware Description and Installation Manual Issue 1.0 6.8 RS-232 Serial Port Wiring The RS-232 female connector, which is a DCE (Data Communication Equipment), is used for various output functions (SMDR, Traffic Reports, etc.) and can be used to access the System database and maintenance functions through connection to a local PC.
  • Page 85: Cable Wiring

    Hardware Description and Installation Manual Issue 1.0 6.9 Cable Wiring To provide a neat professional installation, the wiring to the KSU(s) should be “dressed”. The wiring cables should be bundled and tie wrapped to the KSU(s) and to the wall or rack.
  • Page 86: Rack Mount Wiring

    Hardware Description and Installation Manual Issue 1.0 6.9.2 Rack Mount Wiring To dress the wiring for a Rack mount installation, 1. Ensure all boards are installed and that wiring is completed. 2. Attach the Cord cover to the system.
  • Page 87: Replace The Cord Cover

    Hardware Description and Installation Manual Issue 1.0 6.9.3 Replace the Cord Cover Once the wiring is complete and dressed, the Cord cover should be replaced to minimize accidental damage and the potential of tampering with the wiring. To attach the cover, refer to Figure 6.9.3-1 and perform the following step,...
  • Page 88: Terminal Connection And Wiring

    LDP digital and LIP VoIP phones, standard SLTs, and VoIP phones (SIP or H.323 v3). The specific model of LDP and LIP phones supported in the eMG80 system are shown in the chart below. Table 7.1-1 Terminal Models Supported...
  • Page 89: Terminal Cabling Distance

    Hardware Description and Installation Manual Issue 1.0 7.2 Terminal Cabling Distance The figure 7.2-1 below indicates the wiring distance for Digital Key Telephones and Single Line Telephones, and both must be wired with 22 or 24 AWG twisted pair Cat 3 or Cat 5 cable.
  • Page 90: Terminal Connection

    The wall outlet for the DKT or Console should be wired to the appropriate termination point for the DKT port in the eMG80 system. 1. Using the Modular Jack wiring charts below, wire the 1...
  • Page 91: Slt Wiring

    SLTs are wired to the center pair of the RJ11 jack, typically on the bottom or back of the SLT. The wall outlet should be connected to an appropriate SLT port in the eMG80 system. 1. Wire the center pair of the wall outlet to the termination point using UTP cable.
  • Page 92 DC input on the bottom of the IP Phone and plug the AC plug of the AC adaptor in to a 100-240 VAC outlet. Once the LIP phone powers up, it will attempt to register with the eMG80. From default, the LIP phone should complete the registration successfully. If not, the phone will display the “No Response”...
  • Page 93: Dss/Blf Console Installation & Wiring

    Figure 7.3.4-1 LDP-7048DSS Console install LDP-7048 DSS Console Wiring The LDP-7048 DSS Console is wired as a normal Digital Key Telephone to a separate digital port of the eMG80, refer to Section 7.3.1. LIP-8000 Console Installation and Wiring The LIP-8000E Series DSS/BLF Console is available in three (3) models 12 button w/paper labels (LIP-8012DSS), 12-button w/LCD (LIP-8012LSS), and 48-button w/paper labels (LIP-8048DSS).
  • Page 94 Hardware Description and Installation Manual Issue 1.0 Figure 7.3.4-2 LIP-8000 series Console Configurations Referring to Figure 7.3.4-3 below use the following instructions to install and wire the LIP Console to the associated LIP Phone. 1. Turn the LIP phone and Console upside down 2.
  • Page 95: Terminal Wall Mount

    Hardware Description and Installation Manual Issue 1.0 Figure 7.3.4-3 LIP-8000 DSS Installation 7.4 Terminal Wall Mount 7.4.1 LDP-7000 and LDP-9000 series Wall Mount The LDP-7000 and LDP-9000 series phones can be mounted on the wall using the appropriate Wall Mount Kit. The Wall Mount Kit is installed as described below. A separate Wall Mount kit, available from Ericsson-LG, is required for the LDP-7000 series phones.
  • Page 96: Lip-8000E Wall Mount

    Hardware Description and Installation Manual Issue 1.0 7.4.2 LIP-8000E Wall Mount The LIP-8000E series phones incorporate wall mount into the base of the phone housing. Using the instructions, mount the LIP-8000E series phone on the wall. An LIP phone with Consoles can be Wall Mounted after the Console is properly connected to the LIP phone, refer to section 7.3.4.
  • Page 97: Starting The Ipecs Emg80

    1. Verify the KSU MBU SW1 pole#1 is OFF, and pole#2 is ON. Also verify the AC Power switch is OFF. 2. Plug the AC power cord into the iPECS eMG80 System KSUs and the AC outlet. 3. Turn the AC Power switches on the KSU and EKSU ON.
  • Page 98: Verify The Nation Code

    There are two methods to verify and modify the Nation code. The first is from the Attendant Station, which is the LDP multi-button phone connected to the first DKT port on the KSU MBU. The second is through the eMG80 Install Wizard, section 8.3. 8.2.1 Using the DKT 1.
  • Page 99: Installation Wizard

    Station and Flexible Numbering plans, IP addressing information, etc. The Wizard is part of the eMG80 system Web Admin that is accessed through the LAN port of the KSU. Connect a PC to the LAN connected to the KSU LAN port or directly to the KSU LAN port.
  • Page 100 Hardware Description and Installation Manual Issue 1.0 3. Click [Change Language] at the top of browser and select the desired language and click [Next] to continue. 4. Select the appropriate country from the drop-down selections and enter the site name as you wish.
  • Page 101 Also, use this IP address to identify the MPB in remote devices. IP Address of Domain Name Server, which iPECS eMG80 will use to resolve URL to an IP address. The DNS IP Address 0.0.0.0 DNS provides the resolution after receiving the name from...
  • Page 102 Hardware Description and Installation Manual Issue 1.0 6. Enter Station Index Range and click [Load]. You can change the station number to the new station number if you want the desired number about the current station. Move on to...
  • Page 103 Hardware Description and Installation Manual Issue 1.0 7. Set Numbering plan for CO access, Attendant call, Pickup and Hunt groups, and click [Next] to continue.  Access CO in first CO Group: Dial code to access the 1 available CO Line in any accessible group.
  • Page 104 Hardware Description and Installation Manual Issue 1.0 8. Set CO Ring assignment and click [Next] to continue. Each “Normal” CO/IP line is assigned to signal a station, station group or VSF Announcement for an incoming call (Ring). Separate ring assignments are made for Day, Night, and Timed Ring mode.
  • Page 105 Issue 1.0 9. Set Web Admin User ID and Password. iPECS eMG80 supports up to 10 system account (ID and password). The Access privilege is determined based on the entered system account (ID/Password). Station user ID and password is managed in PGM 227.
  • Page 106: Maintenance & Troubleshooting

    9.2 PSU Fuse Replacement The PSU is located at the left in the KSU and is pre-installed in the iPECS eMG80 KSU. The PSU provides three DC voltage power sources to MBU through the 7-pin connector, CN7. The fuse, which is a rated as 2A @ 250 Volts is located on the lower left of the PSU board.
  • Page 107: Troubleshooting

    Hardware Description and Installation Manual Issue 1.0 9.3 Troubleshooting Table 9.3-1 eMG80 Troubleshooting Chart Problem Cause/Symptom Solution Power short circuit in some Exchange the malfunctioning board for one in board(s) good working condition. System power Dust each board with a dry cloth.
  • Page 108: Open Source Software Notice

    Hardware Description and Installation Manual Issue 1.0 10. O PEN SOURCE SOFTWARE NOTICE This following GPL (General Public License) software used in this product are subject to the GPL License Agreements. You can obtain a copy of the GPL licenses from Ericsson-LG Web Site (http://www.ericssonlg.com).
  • Page 109 Hardware Description and Installation Manual Issue 1.0 Thanks for purchasing iPECS eMG80 The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson-LG shall have no liability for any error or damage of any kind resulting...