Adjust. 9 - MUTOH SC-550 Maintenance Manual

Sc series cutting plotter
Table of Contents

Advertisement

2)
Cutting mat height calibration (roller).
This test measures unevenness of the cutting mat on ± every 40 mm and stores this data in
EEPROM. This data is used to compensate the pen height on this particular places.
* Adjust – 08 *
F3
Xaxisadj
* Roll height *
F3
Measure
(F4) Display is of no importance.

5.3.9. Adjust. 9

1)
Pen force calibration.
* Adjust – 09 *
F3
PenForce
* Pen Force *
F3
Adjustment
Put Pen in the head
Close cover and press
ENTER.
Caution :
You cannot check if the calibration is correct by internal test from the plotter.
Check the calibration by sending a file from the computer.
If you perform the 500mm (20Inch) square again, it will be plotted as before
WITHOUT calibration.
Roller
F4
Press F4
Display
F4
Note :
It is recommended to performed the cutting mat height calibration after
replacement of the cutting mat.
Cutter
F4
Press F3
Plot
F2
Check
F4
Press F3
Press ENTER
Maintenance Manual – SC Cutting Plotter
Without paper loaded, put the Special Adjustment pen
JD-41440 in the penholder.
Press (F4) Roller.
Press (F3) Measure.
Press ENTER to start the test.
The plotter starts to measure the cutting mat height on
every ± 40mm.
Press ENTER to save data.
(F2) Plot is of no importance.
For Pen Force adjustment
Put Adjustment pen JD-41440 in penhead.