5.2.2. Aging.
This test makes the plotter continuously moving in the X-/Y- axis.
This test can be performed without media or with media loaded.
Step 1 :
Power on the plotter in diagnostics mode.
Step 2 :
Press the [ORIGIN] key until 50 % LED is on.
Step 3 :
Press the [VALUE ¯] key. (Unit starts initialising, wait until finished)
Step 4 :
Press [MENU ] key.
Step 5 :
The [NEXT/+] or [LAST/-] key keys will determine what axis is to be aging.
·
[MENU ] will continuous move the X and Y axis.
·
[VALUE ¯] will continuous move the X axis only.
·
VALUE ] will continuous move the Y axis only.
Step 6 :
Power OFF.
5.2.3. Drawings for quality check.
Step 1 :
Power on the unit in Diagnostics mode.
Step 2 :
Put a pen in the head and load some paper.
Step 3 :
Press the [ORIGIN] key until 50% LED is on.
Press the [VALUE ¯] key (Unit starts initialising and loads medium if lever is down. Wait until
Step 4 :
finished)
Step 5 :
Press the [VALUE ] key.
Step 6 :
The next key will determine the kind of drawing to be made.
·
[MENU ¯] for ZIG ZAG test
·
[MENU ] for 45° test
·
[VALUE ¯] for DASH LINE test
·
[VALUE] for circles test
Now you have to position the tool (pen) on the desired place on the medium by using the JOG
keys (arrow keys).
Note :
Press the [VALUE ¯] key to start / pause aging.
Press the [VALUE ] key to end aging and select another axis to be aged if
desired.
Note :
Press the [VALUE ¯] key to start / pause the test drawing.
Press the [VALUE ] key to end and select another drawing
33
Maintenance Manual – SC Cutting Plotter
AP-74030, Rev / B