We strongly suggest that you read these programming instructions in their entirety before beginning any programming of
this telephone entry system.
IMPORTANT!
Many of the advanced features available with this telephone entry system CANNOT be programmed from the
system keypad. These advanced features include relay hold open time zones, security levels, elevator control options and
programming via the internet using DKS servers. If any of these advanced features are used, the system MUST be programmed
with a PC using the DoorKing Remote Account Manager for Windows software, VERSION 6.3.b or higher. Refer to the software
help screen for more information on these advanced features.

3.1 General Programming Information

The DoorKing PC Programmable Telephone Entry System is primarily programmed by
using the DoorKing Remote Account Manager for Windows software. However, the
system can also be partially programmed from the keypad on the front of the entry
system.
Programming the entry system can also be preformed off-site using a user supplied
PC with the DKS software loaded on it. Make sure the RING pin jumper is in place on
the circuit board, which was factory installed. See section 4.6 for more information.
The PC programmable telephone entry system has two relays on the circuit board, all of which are programmable for any
function required. These relays are designated as Relay 1 (R 1), and Relay 2 (R 2).

3.1.1 Programming from a PC

Prior to programming the system with a PC and the DoorKing Remote Account Manager for Windows Software, there is certain
information that you must know and must program into the system before the computer can communicate with the system. See
next page section 3.2 to set-up the telephone entry system for PC programming. Programming the system with a PC may be
accomplished by 1) Phone modem, 2) RS-232 direct connection, 3) RS-422 direct connection, 4) Wireless Connection,
5) TCP/IP LAN direct connection, 6) TCP/IP WAN or Internet, 7) DK Internet-Modem Server. See section 2.4 PC Connection
Options for all layouts and additional hardware that is needed for each. All options require the DoorKing Remote Account
Manager for Windows Software VERSION 6.3.b or higher.

3.1.2 Programming from the Telephone Entry System Keypad

Follow the programming instructions as described in each section of this manual. The system will prompt you with short tones
(beep) when programming steps have been followed correctly, and with a long tone (beeeeeep) when the programming step is
ended. The LCD display will also assist you in viewing the information that you are programming. It is highly recommended that
you complete the resident information in section 7 in back of this manual prior to programming from the system keypad. This
will provide you with the information needed to complete the manual programming sequence (sections 3.2.1 through 3.2.7).
When programming from the system keypad, after each programming step is performed correctly, a short tone (beep) will be
heard. When the programming session is ended, a long tone (beeeeeep) will be heard.
Important Note:
Relay hold open time zones and holiday schedules features CANNOT be programmed from the system keypad.
These advanced features can only be programmed from a PC using the DoorKing Remote Account Manager Software.
1834-065-B-10-14

SECTION 3 - PROGRAMMING

RS 232
CONTRAST
MIC
VOL
3 2 1
SPK
VOL
FEED
BACK
3 2 1
CLK
SEN
G
R I N
ON
MASTER
CODE
OFF
KEYPAD
RING
PHONE
CGND
PSW
MIC
COM
SPKR
IMD
5VDC
IMC
Z
A
2C
2RY
NO
NC
1C
1NC
1NO
BAT
16AC
16AC
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1834

Table of Contents