2.13 Pulse Doppler Devices
Figure 2-34 ADFM tab for Pulse Doppler devices
The 2105 can receive flow data (QMain, Velocity, and Depth)
from a connected Pulse Doppler device, including the standard
depth ADFM, the H-ADFM (large channels), the accQmin
(shallow water measurement), and the Hot Tap (closed and pres-
surized pipes). Teledyne Isco offers a 25-foot 'Y' cable (see Figure
2-38), for connection to a Pulse Doppler instrument.
Note
Pulse Doppler input and Modbus input (see Section 2.14) can-
not be used simultaneously in the same system.
The 2105Ci interface module can push Pulse Doppler ensemble
data to a Flowlink Pro database server. Pulse Doppler support
and pushed data functions are activated by selecting the check
box on the ADFM tab (Figure 2-34). The pushed data function is
configured from the Data tab (Figure 2-24). See Flowlink Pro's
Help menu for detailed instructions on pushed data setup. Make
sure that the baud rate you have selected from the pull down list
matches that of the instrument.
2105 Interface Module
Section 2 Installation and Operation
2-29