Omron SYSDRIVE 3G3RV Series User Manual page 440

High-function general-purpose inverters
Table of Contents

Advertisement

No.
Name
L1-01
Motor protection selection
L1-02
Motor protection time constant
Alarm operation selection during
L1-03
motor overheating
Motor overheating operation selec-
L1-04
tion
Motor temperature input filter time
L1-05
constant
L2-01
Momentary power loss detection
Momentary power loss ridethru
L2-02
time
L2-03
Min. baseblock time
L2-04
Voltage recovery time
L2-05
Undervoltage detection level
L2-06
KEB deceleration time
L2-07
Momentary recovery time
Frequency reduction gain at KEB
L2-08
start
Stall prevention selection during
L3-01
accel
L3-02
Stall prevention level during accel
L3-03
Stall prevention limit during accel
Stall prevention selection during
L3-04
decel
Stall prevention selection during
L3-05
running
Stall prevention level during run-
L3-06
ning
L4-01
Speed agreement detection level
L4-02
Speed agreement detection width
Speed agreement detection level
L4-03
(+/-)
Speed agreement detection width
L4-04
(+/-)
Operation when frequency refer-
L4-05
ence is lost
Frequency reference for loss of fre-
L4-06
quency reference
L5-01
Number of auto restart attempts
L5-02
Auto restart operation selection
L6-01
Torque detection selection 1
L6-02
Torque detection level 1
L6-03
Torque detection time 1
L6-04
Torque detection selection 2
L6-05
Torque detection level 2
L6-06
Torque detection time 2
L7-01
Forward drive torque limit
L7-02
Reverse drive torque limit
Table 10.1 Parameters (Continued)
Fac-
Set-
tory
No.
ting
Setting
1
L7-03
Forward regenerative torque limit
1.0
L7-04
Reverse regenerative torque limit
Protect selection for internal DB
3
L8-01
resistor
1
L8-02
Overheat pre-alarm level
Operation selection after overheat
0.20
L8-03
pre-alarm
Input open-phase protection selec-
0
L8-05
tion
Output open-phase protection
*6
L8-07
0.1
selection
0.1
L8-09
Ground protection selection
0.3
L8-10
Cooling fan control selection
*7
L8-11
Cooling fan control delay time
190
0.0
L8-12
Ambient temperature
OL2 characteristics selection at
*11
L8-15
0
low speeds
100
L8-18
Soft CLA selection
Hunting-prevention function selec-
1
N1-01
tion
120
N1-02
Hunting-prevention gain
Speed feedback detection control
50
N2-01
(AFR) gain
Speed feedback detection control
1
N2-02
(AFR) time constant
Speed feedback detection control
1
N2-03
(AFR) time constant 2
High-slip braking deceleration fre-
120
N3-01
quency width
0.0
N3-02
High-slip braking current limit
2.0
N3-03
High-slip braking stop dwell time
0.0
N3-04
High-slip braking OL time
2.0
o1-01
Monitor selection
0
o1-02
Monitor selection after powerup
Frequency units of reference set-
80.0
o1-03
ting and monitor
0
o1-05
LCD brightness
LOCAL/REMOTE key enable/dis-
0
o2-01
able
STOP key during control circuit
0
o2-02
terminal operation
150
o2-03
Parameter initial value
0.1
o2-04
kVA selection
Frequency reference setting
0
o2-05
method selection
Operation selection when digital
150
o2-06
operator is disconnected
0.1
o2-07
Cumulative operation time setting
Cumulative operation time selec-
200
o2-08
tion
200
o2-09
Factory use
Parameters
Fac-
Name
tory
Setting
200
200
0
95
3
0
0
1
0
60
45
1
1
1
1.00
1.00
50
750
5
150
1.0
40
6
1
0
3
1
1
0
*6
0
0
0
0
0
-
Set-
ting
10
17
10-

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sysdrive 3g3rv-a2004Sysdrive 3g3rv-a2004-eSysdrive 3g3rv-a2007Sysdrive 3g3rv-a2007-eSysdrive 3g3rv-a2015Sysdrive 3g3rv-a2015-e ... Show all

Table of Contents