Omron SYSDRIVE 3G3RV Series User Manual page 120

High-function general-purpose inverters
Table of Contents

Advertisement

nDigital Operator Displays during Autotuning
The following displays will appear on the Digital Operator during autotuning.
Autotuning mode selection: T1-01
Motor base speed: T1-07
(For rotational autotuning)
Autotuning started: TUn10
Autotuning
Autotuning completed
-14
4
Table 4.5 Digital Operator Displays during Autotuning
Digital Operator Display
Stop command input
Description
Using the same procedures as for the programming
modes check and set the T1 parameters according to
information on the previous page.
Be sure that T1-01 (Autotuning Mode Selection) is set
correctly and check safety around the motor and
machine.
The autotuning start display will appear when all set-
tings through T1-07 have been completed. The
A.TUNE and DRIVE indicators will be lit.
Autotuning will start when the RUN Key is pressed
from the autotuning start display.
The digit second from the right in TUn
Motor 1/2 Selection (T1-00) and the right digit is the
Autotuning Mode Selection (T1-01).
If the STOP Key is pressed or a measurement error
occurs during autotuning, and error message will be
display and autotuning will be stopped.
Refer to Errors during Autotuning on page 7-12.
END will be displayed after approximately 1 to 2 min-
utes, indicating that autotuning has been completed.
oo
is the

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sysdrive 3g3rv-a2004Sysdrive 3g3rv-a2004-eSysdrive 3g3rv-a2007Sysdrive 3g3rv-a2007-eSysdrive 3g3rv-a2015Sysdrive 3g3rv-a2015-e ... Show all

Table of Contents