Using the DC Injection Brake
Set parameter b2-03 to apply the DC injection brake voltage to the motor while it is coasting to a stop, to stop
the motor and then restart it.
Set b2-03 to 0 to disable the DC injection brake at start.
Set the DC injection brake current using b2-02.
nRelated Parameters
Name
Param-
eter
Num-
LCD Display
ber
DC injection braking cur-
rent
b2-02
DCInj Current
DC injection braking time
at start
b2-03
DCInj Time@Start
nInputting the DC Injection Brake Command from Control Circuit Terminals
If a multi-function input terminal (H1-oo) is set to 60 (DC injection brake command), the DC injection
brake is applied to the motor by turning ON the terminal (the DC injection brake command) when the Inverter
is being stopped.
The time chart for the DC injection brake is shown below.
DC injection brake command
FRUN
Output frequency
If you input the DC injection brake command from an external terminal, or if the run command
and jog command are input, the DC injection brake will be disabled, and operation will
resume.
Description
Set the DC Injection Braking Current as a percent-
age of the Inverter rated current.
Used to set the time to perform DC injection brak-
ing at start in units of 1 second.
Used to stop coasting motor and restart it. When
the set value is 0, DC injection braking at start is
not performed.
DC injection brake
E1-09
Fig 6.19 DC Injection Brake Time Chart