LYNX Touch Installation and Setup Guide
Programming the Control
During the registration process the following messages may be displayed:
Message
Getting Configuration File...
Registering...
Registration Successful!
Registering – Try Later!
Registration Failed!
Invalid Configuration!
Timed Out.
Central Station Database Full.
Primary Sub ID Bad.
Primary ID – Need PIN.
Account Disabled.

Register Device with PIN

This procedure is used to replace one LYNX Touch module with another.
SCREEN
Comm. Diagnostics
Setup
Communication
During the registration process the following messages may be displayed:
Message
Registering...
Registration Successful!
Registering – Try Later!
Registration Failed!
Invalid Configuration!
Timed Out.
Primary ID – Need PIN.
The configuration file is obtained from AlarmNet if the module was programmed through
AlarmNet Direct or a previously programmed module was defaulted.
The registration message is sent and the unit is waiting for the acknowledgement.
The module is registered and is now in full service and available for alarm reporting to the
central station.
Error Message indicates the module is busy.
Error message followed by one of the messages below:
Indicates the configuration is invalid.
Displayed if no response to the registration request is received.
Indicates CS database has more than 1000 subscribers.
Indicates the city, central station, or customer number for the labeled account is not
accepted. The ID information was either entered incorrectly, or the central station failed to
pre-authorize programmed ID numbers with AlarmNet customer service.
Indicates the city, central station, or customer number for the labeled account is not
accepted. The ID information was either entered incorrectly, or the central station failed to
pre-authorize programmed ID numbers with AlarmNet customer service. See the Register
Device With PIN section.
Displayed if the account is disabled in AlarmNet.
1. Select "Comm. Diagnostics" The System displays the following options depending upon
the communication device that is installed:
Communication
Status
Communication
ID Numbers
2. Select "Setup Communication". The System advances to the Registration screen and
the following options are displayed:
Register
Device
Update
Server
3. Select "Register Device With PIN".
(provided by your central station, your dealer or an authorized AlarmNet
representative) on the displayed keypad then select "Done". (Refer to the
table below for applicable registration messages.)
Note: Register Device With PIN can be cancelled by selecting "Cancel". The registration
process is aborted and the message Registration Cancelled! is displayed.
The registration message is sent and the unit is waiting for the acknowledgement.
The PIN number is valid and module is registered and is now in full service and available
for alarm reporting to the central station. The old module is unregistered. Additionally,
AlarmNet sends a substitution alarm to the central station.
Error Message indicates the module is busy.
Error message followed by one of the messages below:
Indicates the configuration is invalid.
Displayed if no response to the registration request is received.
Indicates PIN that was entered is invalid.
Meaning
ACTION
Ethernet
Information
Test
Communication
Register Device
With PIN
Factory
Defaults
Enter a 4-digit alphanumeric PIN number
Meaning
- 46 -
GSM
Information
Setup
Communication