System Operation

"Follow Me" System Announcement Feature

This feature allows the LYNX Touch to deliver a voice system message to the user phone numbers
programmed by the installer. The LYNX Touch will first transmit reports to the Central Station and after
receiving its kiss-off the system will dial the user phone numbers and begin transmitting the welcome
message "System Message, Press Star to Play". The system will dial the user phone numbers a maximum of
eight times.
The "Follow Me" System announcements feature is only supported if PSTN line is available. The
announcements are individually sent to the phone, numbers which are programmed as Phone 1 and Phone 2
respectively in the Reporter Programming section. System Follow Me announcements are triggered by a
system event that belongs to one of the Event Groups enabled by Installer individually for the programmed
phone number(s). The groups are listed below.
All Bypassing actions by a user
Any Open/Close (arming/disarming status changes)
Any Alarms
Any Alarm Restores
Alarm Cancel by the user
Any System Troubles
Any Test
Non-security Events
If a "*" key is not pressed, LYNX Touch will announce "System message Press * to Play" for 45 seconds
before hanging up and redialing the programmed number. The control will make eight attempts before
unsuccessfully ending the System "Follow Me" session and erasing all the events in the queue. The next call
will be triggered by a new event from the Event Group enabled for the programmed number(s).
If a "*" key is pressed, LYNX Touch will play back a sequence of System "Follow Me" announcements from
the queue in chronological order starting with the oldest one. The announcements will include "End of
Message" at the end of the "Follow Me" announcements.
If a "*" key is pressed again during playback or within 15 seconds following the end of the playback, the
control will repeat the sequence. Otherwise the system will hang up, successfully ending the System "Follow
Me" session. Because the "*" key was pressed LYNX Touch will not redial the number again. The next call
will be triggered by a new event from the Event Group enabled for the programmed number(s).
Note: The follow me system announcement will be terminated if any other event requires the system to send a report to the
Central Station. Once the PSTN line is available the session will be resumed and the control will again make up to 8
delivery attempts.
Follow Me Event Triggers
AC Loss
Audible Panic
Automatic Disarmed
Battery Failed Under Load
Burglary Zone Bypass
Carbon Monoxide Detected
Disarmed From AWAY or STAY
Emergency Alarm
Entry/Exit Alarm
Exit Error Alarm (zone)
Expansion Module Tamper
Expansion Module Failure
Expansion Module Tamper Alarm
Expansion Module Tamper Trouble
Fire Alarm
Fire Trouble
** = Zone Number
Follow Me
Announcement
AC Loss
Panic Alarm
Disarmed
System Low Battery
Zone ** Bypassed
Carbon Monoxide Alarm
Disarmed
Emergency Alarm
Perimeter Alarm
Perimeter Alarm
Tamper Alarm
System Trouble
Tamper Alarm
Tamper Alarm
Fire Alarm
System Trouble
- 54 -
Follow Me Event Triggers
Interior Alarm
Keypad Panic
Manual Test
Medical Alarm
Perimeter Alarm
Remote Disarm
RF Sensor Lost
Sensor Low Battery or Tamper
Silent Burglary
Siren Tamper
System Inactivity
System Low Battery
Water Leakage Alarm
Zone Bypass
Zone Tamper (Alarm)
Zone Trouble
Follow Me
Announcement
Interior Alarm
Panic Alarm
System Test
Emergency Alarm
Perimeter Alarm
Disarmed
System Trouble
Sensor Trouble
Silent Burglary
Tamper Alarm
No Check In
System Low Battery
Auxiliary Alarm
Zone ** Bypassed
Tamper Alarm
System Trouble

Hide quick links: