Installing the L5000-RJ31X in the LYNX Touch Control

An auxiliary L5000-RJ31X receptacle can be installed in the LYNX Touch that will allow the telephone cable
to be disconnected without requiring the unit to be opened up.
1.
Using a wire cutter or knife cut the plastic tabs that secure the receptacle knockout from the left side of the LYNX Touch back case.
2.
Connect four wires between the L5000-RJ31X receptacle terminal strip and the incoming phone line and the premises telephones
as shown on the figure below.
3.
Install the L5000-RJ31X receptacle into the slot on the back case.
4.
Connect one end of the L5000-RJ31X cable to the 8-position jack on the LYNX Touch PC board.
5.
Route the cable through the opening in the back case and along the wire channel in the back case.
6.
Connect the other end of the cable to the L5000-RJ31X receptacle on the side of the back case as shown below.
7.
Secure the wires to the tie wrap points on LYNX Touch front and back case with the provided tie wraps.
To allow flush wall or desk mounting of the control, ensure that L5000-RJ31X cable is routed through the
channel in the case back. Ensure enough slack is left in the wires to allow the case to close without pinching
the wires.
L5000-RJ31X
CABLE
L5000-RJ31X WIRING
L5000-RJ31X
TERMINAL STRIP
TO PREMISES
INCOMING
TELEPHONES
PHONE LINE
INCOMING / PREMISES TELEPHONE WIRING
L5000-RJ31X
REFER TO
WIRING
SCHEMATIC
FOR
CONNECTIONS
REMOVE
KNOCKOUT
- 8 -
TIE WRAP
POINT
TIE WRAP
POINT
5100-100-063-V0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents