Honeywell LYNX Touch Series Installation And Setup Manual page 27

Hide thumbs Also See for LYNX Touch Series:
Table of Contents

Advertisement

SCREEN
Sub ID
Supervision
24 Hours
Old Alarm Time
10 Minutes
Remote Acc. Comm.
Disabled
Multi Mode Comm.
Disabled
IP Fault Time (min)
00
Use DHCP
Yes
NIC IP Address
255.255.255.255
Subnet Mask
255.255.255.255
Gateway IP Address
255.255.255.255
DNS Server IP Address
255.255.255.255
GSM Fault Time (min)
00
GSM Rollover
No
GSM 24 Hour Test
No
6.
Select "Sub ID". Enter the 4-digit Subscriber Account Number (Decimal).
Options
0001-9999
7.
Select "Supervision". The system scrolls between the following options:
24 Hours
None
30 Days
8.
Select "Old Alarm Time". The system scrolls between the following options. Use the
down
arrow to scroll to the next page of options.
10 Minutes
15 Minutes
30 Minutes
1 Hour
2 Hours
4 Hours
8 Hours
12 Hours
24 Hours
9.
Select "Remote Acc. Comm". The system toggles between "Disabled" and
"Enabled".
Note: This field will not be programmable unless it is enabled when creating the Communications
Module account in AlarmNet.
10. If "Remote Access Comm." was enabled in the previous step, the "Multi Mode
Comm." option is displayed. The system scrolls between the following options.
Disabled
Relay Reports
Enhanced Reports
Note: This field will not be programmable unless it is enabled when creating the Communications
Module account in AlarmNet. The Relay Reports option should not be selected when using
TotalConnect 2.1 Service.
11. Use the down
arrow to scroll to the next page of options. If IP was selected in
step 2, proceed to step 12. If GSM was selected in step 2, proceed to step 19.
12. Select "IP Fault Time (min)". Enter the time delay (in minutes) on the keypad.
Options
00-99
13. Select "Use DHCP". The system toggles between "Yes" and "No". If "No" is selected
the system displays four additional options. If "Yes" is selected, skip to step 18.
14. Select "NIC IP Address". Enter the 4-part address on the displayed keypad.
15. Select "Subnet Mask". Enter the 4-part address on the displayed keypad.
16. Select "Gateway IP Address". Enter the 4-part address on the displayed keypad.
17. Select "DNS Server IP Address". Enter the 4-part address on the displayed keypad.
18. If "IP" was selected in step 2, select "Save" and then select "OK" when the
"Programming Done" screen appears. Proceed to "Diagnostics" section in order to
register the device.
19. Select "GSM Fault Time (min)". Enter the time delay (in minutes) on the keypad.
Options
00-99
20. If "WiFi and GSM" was selected in step 2, two additional programming fields are
displayed. Select "GSM Rollover", the system toggles between "Yes" and "No".
19. Select "GSM 24 Hour Test", the system toggles between "Yes" and "No".
20. If "GSM" was selected in step 2, select "Save" and then select "OK" when the
"Programming Done" screen appears. Proceed to "Diagnostics" section in order to
register the device.
- 27 -
LYNX Touch Installation and Setup Guide
Programming the Control
ACTION