CAUSE:Failed PWB-A board.
SOLUTION:Replace the PWB-A board (p/n 4040 0101 03).
Note : Abort code 0x00E004F0 may also be indicated.
SPECIAL NOTE : Solution contribution by Tom Kelly, Workgroup/SSD
TAUS0703415EN*
Solution ID
Description
EA006 error code when scanning.
Solution
CAUSE: CorruptMFP data.
SOLUTION:Perform aTotal Clearand reset all Network Settings.
Note : Please review the attacheddocument for instruction on performing the Total Clear and the settings which will need to be reapplied.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
Solution ID
TAUS0703419EN*
Description
Change in IC3 ordering procedure.
Solution
IC3 is no longeravailable as a separate item. It isno longer necessary to fill out the online NVRAM claim form to request IC3.
IC3 is part of thePWB-A. Therefore, ordera new PWB-A (p/n 404001010E), which includes IC3.
SPECIAL NOTE: Solution contribution by Tony Pizzoferrato, ESS/BSE
Solution ID
TAUS0703607EN*
Description
The machine does not recognize the duplex unit.
Solution
PROBABLE CAUSES:
1. The switchback unit was not properly seated or has come loose.
Reseat the switchback unit and ensure that it is seated firmly on the machine.
2. PJ20 on PWB-A is not seated correctly.
Reseat the connector.
SPECIAL NOTE : Solution contribution by Chuck Tripp, Production Print/SSD
TAUS0651694EN*
Solution ID
Description
CLOSE > SECTION PROPERLY message with an illustration of the document feeder raised when an original is placed in the document feeder.
Solution
CAUSE: The magnet on the bottom, right, front of the document feeder is not properly aligned with the reed switch which is under the cover.
SOLUTION: Loosen the screws below the right hinge of the document feeder to align it. The document feeder manual lists this adjustment to correct
document skew so ensure that the documents do not skew after changing this adjustment. The specification for maximum skew is 3mm.
SPECIAL NOTE: Solution contribution by Jim Behrends, Workgroup/SSD
Solution ID
TAUS0703617EN*
Copyright 2009, Konica Minolta Business Solutions U.S.A., Inc.
Warm-up, wrong display, incorrect operation, lock-up
94
4
Solution Usage
Solution Usage
4
Solution Usage
4
3
Solution Usage
Solution Usage
3
October 2009

Advertisement

Table of Contents
loading

Table of Contents