To configure Access Combo:
press Menu > Options > Access Options > Access Comb >
Select the combination you want for example Comb1 > OK > input the number, in this case
123 to represent GRP TP1, GRP TP2, GRP TP3> OK

Lock

The opening period of electromagnetic lock or door bolt can be controlled according to
your requirement or preference. The default value is 150 which translates to 3 sec. 50 is
equivalent to 1 second. Press Menu > Options > Access Options > Lock > Determine the
value of lock delay.

Door Sensor Delay

Door sensor delay can be configured to alert users if a door is not closing well after a time
period. Door sensor must be installed prior to activation of this option. The default period
is 10seconds and the maximum period is 999seconds. Press Menu > Options > Access Op-
tions >Dsen Delay > Determine the value of lock delay.

Door Sensor Mode

Door sensor mode is to configure the time to alert an internal buzzer if the door is not clos-
ing properly. The standard of door locking system includes:
Normally Closed (NC):
An electrical contact that regularly allows electricity to flow until it
is signaled to open
Normally Open (NO).:
An electrical contact that rarely allows electricity to flow. To use
door sensor, select NC. Press Menu > Options > Access Options > Dsen Mode > Determine
the type correctly > OK

Door Sensor Alarm

Door Sensor Alarm can be configured to alert users using alarm system if a door is not
closing well after a time period. Alarm system must be installed first to use this operation.
Press Menu > Options > Access Options > Dsen Alarm > Determine the period > OK

Turning Off Alarm

There are scenarios that require you to turn off your alarm system and this can be done
through the terminal. To do this you have to press and hold the security button at the back
of the reader followed by pressing Menu > Turn Off Alarm.If you didn't press the security
button, "System Broken!!!" message will be displayed when you press the Turn Off Alarm
operation button.

Duress Options

Duress Option is to allow user to use his fingerprint in duress situations. The terminal will
trigger an alarm system after receiving a successful verification from a duress fingerprint.