Lamp Suddenly Turns Off; Flicker, Shadows Or Dimness; Lcd; Blank Screen, No Menu Displaying - Christie M Series User Manual

M series
Hide thumbs Also See for M Series:
Table of Contents

Advertisement

Section 6: Troubleshooting

6.2.2 Lamp Suddenly Turns OFF

1. Check lamp power through the remote keypad checking the Lamp menu or from the web user interface
Advanced: Lamp menu. Try increasing lamp power.
2. Check for an alarm condition on the LCD keypad display.
3. Replace the lamp.

6.2.3 Flicker, Shadows Or Dimness

1. Check lamp power through the remote keypad checking the Lamp menu or from the web user interface
Advanced: Lamp menu. Try increasing lamp power.
2. Replace the lamp.
6.3

LCD

6.3.1 Blank Screen, No Menu Displaying

1. Press any arrow key on the built-in keypad. The backlight on the LCD and the backlight for the built-in
keypad should turn on. If the LCD is still blank, restart the projector.
6.4

Remote Keypad

6.4.1 Remote Keypad Does Not Seem to Work

1. Replace the batteries.
2. Check if IR signals are received by the projector. Pressing any key on the remote control towards the front
or rear sensor, the Status LED will blink, regardless if any command is executed. If the LED does not
blink, restart the projector.
3. Ensure the remote keypad is enabled. If the projector is powered, using the built-in keypad, open the OSD
menu and go to the Main Menu>Configuration>Communication submenu and check the check boxes for
Front IR Enabled and Rear IR Enabled are checked. Enable them if they were disabled and try again.
4. Projector is busy. If the projector is busy in a warm-up mode or in a cool-down mode, the commands from
the remote keypad may be ignored. Wait until the projector reaches a stable state (Power ON or Stand By)
and try again.
5. Press the PROJ key on the remote keypad. If this brings up a pop-up box on the OSD, ensure that the
check box is marked to enable the projector.
6. Using the XLR connector, use the remote as a "wired" keypad. If it does work and all the IR sensors have
been enabled, then there may be a problem with the IR sensors.
6-2
M Series User Manual
020-100009-04 Rev. 1 (10-2009)

Advertisement