Transmission Settings; Remote Control Protocol - EverFocus EDR810H Insruction Manual

Dvr
Hide thumbs Also See for EDR810H:
Table of Contents

Advertisement

15.1
Transmission Setting
There are 6 different speeds that can be used to transmit instruction or
information through the RS232/RS485 port on the device, 1200 baud, 2400
baud, 4800 baud, 9600 baud, 19200 baud, and 3840 baud. The default setting
from the factory is 9600 baud. Please refer to RS232/RS485 Setting Menu on
page 32 for details.
15.2

Remote Control Protocol

A computer can be used to control the DVR by sending the packet as follows.
===============================================
==========
EDR410/810 485/232 Control Code Protocol
===============================================
==========
1-1. Sample control code packets
Example1: A packet that send "REC" key to EDR(ID=5)
0x85 (length)
0x00 (Receiver ID high byte)
0x05 (Receiver ID low byte)
0x4B (OPcode = key)
0x08 (DATA1 = "Rec" keycode)
0x5D (checksum)
Example2: A packet that send "PAUSE" key to EDR(ID=4999)
0x85 (length)
0x27 (Receiver ID high byte)
0x07 (Receiver ID low byte)
0x4B (OPcode = key )
0x0C (DATA1 = "Pause" keycode )
0x0A (checksum)
Example3: A packet that send "PLAY" key to all EDR(broadcast)
0x85 (length)
0x7f (Receiver ID high byte)
0x7f (Receiver ID low byte)
0x4B (OPcode = key )
0x0B (DATA1 = "Play" keycode )
0x59 (checksum)
116

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edr810mEdr410mEdr410h

Table of Contents