recording before making change of INSTALL. To take full advantage of
the record resource, switch the Uninstalled Camera Ports to OFF in this
section. For covert, select "ON" to cover a camera, and disable the screen
in live mode to show up. However, the image is recorded, and can be
played back by user who has playback right. The covert channels will not
show up on the sequence mode. To change this, simply use the Jog Dial
on the DVR. Press the Enter key to make your selection.
SEQ (MAIN/CALL): Setup a retention period for sequences. To
change this, simply use the Jog Dial on the DVR. Press the Enter key to
make your selection.
REC QUALITY: Select an image quality for recording. Normal record
image quality and event record image quality can be set individually. There
are six different qualities available. A higher image quality needs more
HDD space. To change this, simply use the Jog Dial on the DVR. Press
the Enter key to make your selection. The theory space needed per
second lists below:
ESTIMATE KILOBYTES
SUPERIOR: 512 Kilobytes = 0.5 MB
HIGH: 448 Kilobytes = 0.438 MB
STANDARD: 384 Kilobytes = 0.375 MB
BASIC: 320 Kilobytes = 0.313 MB
LOW: 256 Kilobytes = 0.25 MB
LOWER: 192 Kilobytes = 0.188 MB
Since Variable Bit Rate (VBR) might be used, therefore this table is
for your reference only.
REC SPEED ON TIME ZONE:
TP: Scheduled recording time 1~8 which can be set in the
SCHEDULE SETUP MENU. "N" in the column of "TP"
is the normal recording time.
NORMAL: Normal record speed (Images per second) up to 30
IPS. EDR810/410 will adjust to the maximum
recording speed by calculating the total installed
cameras that have enabled in the CAMERA SETUP
MENU.