1. SPECIFICATIONS OF MOTION SYSTEM COMPONENTS
5)
IN
OUT
No.
Name
Extension cable
1)
connector
2)
Base cover
3)
Module connector
4)
Unit fixing screw
5)
Base mounting hole
6)
DIN rail hooks
*1 : Install the supplied blind cap or blank cover (A1SG60) to prevent dust penetrating the empty
connector spaces. Failure to do so may cause malfunctioning.
(d) Extension base unit (A168B)
2)
1)
6)
Connects to the signal communications connector on the main base unit or bus
coupling type GOT with the extension cable.
Take off the supplied connector cover before connecting the extension cable.
A cover for protecting the extension cable connector.
When connecting to bus coupling type GOT, cut out the area surrounded by the groove
under the word "OUT" on the base cover with side cutters, or other appropriate tool.
Connectors to mount the Power module, I/O module, and special-function modules.
Install the supplied connector cover or blank cover (A1SG60) to prevent dust
penetrating empty connector spaces.
Screws to fix the unit to the base.
Screw size M4 12.
Slots for mounting the base unit onto the control board panel (for M5 screws).
Hooks to attach to the DIN rail.
A168B........................ 2
Application
CAUTION
1 − 32
4)
2)
OUT
A168B
*1
3)
1)