APPENDICES
(4) MR-J2HBUS M
(a) Explanation of type
Type: MR-J2HBUS M
(b) Connection diagram
When fabricating a cable, use the recommended wire given on Appendix
1.1 (1), and make the cable as shown in the following connection diagram.
The overall distance of the SSCNET cables on the same bus is 30m.
10120-6000EL(connector)
10320-3210-000(shell kit)
LG
1
LG
11
RD
2
RD*
12
3
13
TD
4
TD*
14
LG
5
LG
15
6
16
EMG
7
EMG*
17
8
18
BAT
9
19
10
20
SD
Plate
Symbol Cable Length [m]
05
0.5
1
1
5
5
MR-J2HBUS M
10120-6000EL(connector)
10320-3210-000(shell kit)
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
Plate
APP − 4