5. If eXFlash DIMM, make sure the eXFlash DIMM FW is updated to the latest level.
6. If the DIMM problem persists and there are no other DIMMs with the same indication, replace the DIMM.
7. If the eXFlash DIMM problem persists and there are no other eXFlash DIMMs with the same indication, confirm
that the eXFlash DIMM is under warranty before replacement.
Related Links:
v
"Server features and specifications" on page 7
v
"Removing a DDR3 compute book" on page 283
"Replacing a DDR3 compute book" on page 284
v
"Removing the DDR3 compute book cover" on page 218
v
"Replacing the DDR3 compute book cover" on page 220
v
"Removing a memory module" on page 239
v
"Replacing a memory module" on page 240
v
"Flash DIMMs" on page 51
v
806f090c-2b84ffff
[PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: Memory on Compute Book 4 has been throttled due to high temperature detected by the DIMM
sensor.
May also be shown as 806f090c2b84ffff or 0x806f090c2b84ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response: Complete the following steps until problem is solved:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Check IBM Support site for Service Bulletins/RETAIN tips related to an throttled DIMM Condition.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
Related Links:
"Server features and specifications" on page 7
v
"Removing a DDR3 compute book" on page 283
v
v
"Replacing a DDR3 compute book" on page 284
"Removing the DDR3 compute book cover" on page 218
v
"Replacing the DDR3 compute book cover" on page 220
v
"Removing a memory module" on page 239
v
"Replacing a memory module" on page 240
v
Appendix B. Integrated management module II (IMM2) error messages
806f090c-2b84ffff
1159