Bit Switches - 6
Message reception selection from
non-registered SIP server
4
0: Answer
1: Not answer
ECM communication setting
5
0: No limit for image compression
1: Limit for image compression
No.
Function
Effective field limitation for G3
0
standard function information
0: OFF, 1: 4byte (DIS)
Switching between G3 standard
and G3 non standard
1
0: Enable switching
1: G3 standard only
ECM frame size selection at
3
transmitting
0: 256byte, 1: 64byte
DIS detection times for echo
4
prevention
0: 1 time, 1: 2 times
CTC transmission selection
5
0: PPRx1
1: PPRx4
Shift down setting at receiving
6
negative code
0: OFF, 1: ON
D702
0: This answers the INVITE message from
the SIP server not registered for the
machine.
1: This does not receive the INVITE
message from the SIP server not registered
for the machine and send a refusal
message.
0: This does not limit the type of the image
compression with ECM communication.
1: When the other end machine is Ciscco,
this permits the image compression other
than JBIG or MMR with ECM
communication.
IP Fax Switch 03 (SP No. 1-111-004)
Limits the effective field for standard G3
function information.
Enables/disables switching between G3
standard and G3 non-standard.
Selects the ECM frame size for sending.
Sets the number of times for DIS to detect
echoes.
When "0" is selected, the transmission
condition is decided by error frame
numbers.
When "1" is selected, the transmission
condition is based on the ITU-T method.
Selects whether to shift down when
negative codes are received.