Ricoh D158 Service Manual page 278

Lanier, ricoh, savin
Table of Contents

Advertisement

Service Call Conditions
No.
Definition
ID sensor : Auto adjustment time-out (In-process) (D158/D159)
354
B
When the ID sensor is
adjusting Vsg automatically.
P sensor error (D158/D159)
SC350~354 happen during
355
D
normal operation. This error
isn't displayed on the panel
but is left in the error log.
TD sensor error (D158/D159)
Detected the following value
TD sensor output value <
389
D
0.2V
TD sensor output value >
4.0V
10 times in series.
D158/D159/D160/D161/D170
Symptom
5-14
Possible Cause
Defective ID sensor
Disconnection of the harness to the
ID sensor
Bad electrical contact of the ID
sensor connector
Defective BCU
Defective laser unit
Defective developer density
Defective high-voltage power pack
Dirty ID sensor
Defective ID sensor
Disconnection of the harness to the
ID sensor
Bad electrical contact of the ID
sensor connector
Defective BCU
Defective laser unit
Defective developer density
Defective high-voltage power pack
Dirty ID sensor
Defective TD sensor
Bad contact of the connector to the
TD sensor