Service Call Conditions
No.
Definition
Zero cross signal malfunction(D158/D159)
Zero cross signals are
detected three consecutive
times at 50 ms intervals.
547
B
This error is detected before
-01
the fusing relay is turned on
after turning on the main
power or closing all the
doors.
Zero cross signal malfunction (D158/D159)
The zero cross signal is not
detected for 3 seconds even
547
B
though the fusing relay is on
-02
after turning on the main
power or closing all the
doors.
Zero cross signal malfunction(D158/D159)
A detection error occurs
twice or more in 11
547
B
frequency detections. This
-03
error is defined when the
detected zero cross signal is
less than 45.
Zero cross signal malfunction (D160/D161/D170)
547
B
Detecting low-frequency
wave
D158/D159/D160/D161/D170
Symptom
5-22
Possible Cause
Defective fusing relay
Defective fusing relay circuit
Defective PSU
Power supply board
Defective fusing relay
Defective fusing relay circuit
Defective PSU
Power supply board
Defective fusing relay
Defective fusing relay circuit
Defective PSU
Power supply board
Defective PSU
Defective BICU
SM