Ricoh D158 Service Manual page 908

Lanier, ricoh, savin
Table of Contents

Advertisement

Bit Switches - 1
No
Function
TTI printing position in the main
0-7
scan direction
No
Function
Going into the Energy Saver
mode automatically
1
0: Enabled
1: Disabled
Interval for preventing the
machine from entering Energy
Saver mode if there is a
pending transmission file.
4-5
Bit 5
Bit 4
0
0
0
1
1
0
1
1
D702
System Switch 12 (SP No. 1-101-019)
TTI: 08 to 92 (BCD) mm
Input even numbers only.
This setting determines the print start position
for the TTI from the left edge of the paper. If
the TTI is moved too far to the right, it may
overwrite the file number which is on the top
right of the page. On an A4 page, if the TTI is
moved over by more than 50 mm, it may
overwrite the page number.
System Switch 15 (SP No. 1-101-022)
1: The machine will restart from the Energy
Saver mode quickly, because the +5V power
supply is active even in the Energy Saver
mode. The LED of the operation switch is
flashing instead of entering Energy Saver
mode.
Use this setting if an external telephone has to
be used when the machine is in the Energy
Saver mode.
If there is a file waiting for transmission, the
machine does not go to Energy Saver mode
during the selected period.
Setting
After transmitting the file, if there is no file
1 min
waiting for transmission, the machine goes to
30 min
the Energy Saver mode.
1 hour
24 hours
Comments
Comments