Ricoh D158 Service Manual page 867

Lanier, ricoh, savin
Table of Contents

Advertisement

Code
Meaning
0-85
The line was disconnected
due to abnormal signaling in
V.34 control channel restart.
0-86
The line was disconnected
because the other terminal
requested a data rate using
MPh that was not available in
the currently selected symbol
rate.
0-87
The control channel started
after an unsuccessful primary
channel.
0-88
The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
2-11
Only one V.21 connection flag
was received
2-12
Modem clock irregularity
2-13
Modem initialization error
2-22
Counter overflow error of
JBIG chip
2-23
JBIG compression or
reconstruction error
2-24
JBIG ASIC error
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
SM
Suggested Cause/Action
The signal did not stop within 10 s.
Turn off the main power switch, then turn it
back on.
If the same error is frequent, replace the
FCU.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.
The receiving terminal restarted the
control channel because data reception in
the primary channel was not successful.
This does not result in an error
communication.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.
Replace the FCU.
Replace the FCU.
Turn off the machine, then turn it back on.
Update the modem ROM.
Replace the FCU.
If error occurs frequently, change the settings
for resolution, paper size, compression type.
Turn off the machine, then turn it back on.
Turn off the machine, then turn it back on.
JBIG data error
Check the sender's JBIG function.
Update the FCU ROM.
25
Error Codes
D702

Advertisement

Table of Contents
loading

Table of Contents