Parameters; Fax Parameters - Ricoh M052 Service Manual

Mfps & printers m052; m053; m054
Hide thumbs Also See for M052:
Table of Contents

Advertisement

Dedicated Transmission Parameters

4.5.2 PARAMETERS

Fax Parameters

The initial settings of the following fax parameters are all FF(H) - all the parameters are
disabled.
Switch 00
FUNCTION AND COMMENTS
ITU-T T1 time (for PSTN G3 mode)
If the connection time to a particular terminal is longer than the NCU parameter setting,
adjust this byte. The T1 time is the value stored in this byte (in hex code), multiplied by 1
second.
Range:
0 to 120 s (00h to 78h)
FFh - The local NCU parameter factory setting is used.
Do not program a value between 79h and FEh.
Switch 01
No
Tx level
Bit4
Bit3
0
0
0
0
0
0
0-4
0
0
0
0
0
1
1
1
M381
FUNCTION
Bit2
Bit1
Bit0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
1
1
1
1
1
Disabled
COMMENTS
If communication with a particular
remote terminal often contains
0
errors, the signal level may be
–1
inappropriate. Adjust the Tx level for
communications with that terminal
–2
until the results are better.
–3
If the setting is "Disabled", the NCU
parameter 01 setting is used.
–4
Do not use settings other
than listed on the left.
–15
118
SM

Advertisement