Ricoh M052 Service Manual page 263

Mfps & printers m052; m053; m054
Hide thumbs Also See for M052:
Table of Contents

Advertisement

System SP5-xxx
5504
[Jam Alarm]
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
001
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
5505
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 -
[Supply Alarm]
5507
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm
002 Staple Supply Alarm
004 Maintenance Kit Alarm
009 Cartridge Supply Alarm
080 Toner Call Timing
128 Interval :Others
133 Interval :A4
M052/M053/M054
*CTL
-
*CTL
[0 to 255 / 27 / 100 copies /step]
*CTL
-
0: Off, 1: On
0: Off, 1: On
0: Off, 1: On
0: Off, 1: On
Changes the timing of the "Toner Supply Call" via
the @Remote, when the following conditions
occur.
0: At replacement
1: At near end
[250 to 10000 / 1000 / 1 /step]
5-50
SM

Advertisement

Table of Contents
loading

Table of Contents