Electrical Equipment
THROTTLE VALVE POTENTIOMETER
(ACCELERATOR SENSOR) CHECK
With motor off:
•
Disconnect the three-way connector (black) (1).
CAUTION
During reassembly ensure correct coupling of the
electrical connector (1).
•
Set the ignition switch to " ".
•
With a multimeter (scale kΩ), measure the
resistance between the potentiometer terminals.
MEASUREMENT (A)
Resistance between the two terminals A and B, in any
position of the throttle valves:
Standard value: 5 kΩ Ω Ω Ω Ω ± 10%
MEASUREMENT (B)
Resistance between the terminals A and C:
From the value of the throttle completely closed,
accelerating progressively up to completely open, the
resistance will vary as follows:
Standard value: from 1 kΩ Ω Ω Ω Ω to 6 kΩ Ω Ω Ω Ω ± 10%
NOTE
To unscrew the two screws more easily, block
with LOCTITE
®
243, preheat with a blow of hot air.
•
Unscrew and remove the screws.
•
Remove the potentiometer.
If the resistance values are different from those
prescribed, replace the potentiometer.
chap. 6
Release 00
2002-09
Atlantic 500
1
A
6
B
C
6-13