DROP SENSOR CHECK

With motor off:
Remove the front hood, see (REMOVING THE
FRONT HOOD).
Check that the sensor (1) is mounted correctly (with
the arrow imprinted on the rubber pointing upwards).
Partially remove the fuse carriers (2).
Disconnect the two-way connector (3)(white/grey)
and take measurements (on terminals sensor
side).
CAUTION
During reassembly ensure correct coupling of the
electrical connector (3).
With a multimeter (scale x 100 kΩ), measure the
resistance between the black and white/black
cable terminals (N -Bi/N).
Standard value: resistance 62 kΩ Ω Ω Ω Ω ± 15%
Remove the sensor (1) with the rubber washer in
its housing, and lean it sideways to an angle of
more than 45° (simulating the parking position).
Standard value: 0 - 1 Ω Ω Ω Ω Ω
If the resistance is different from that prescribed,
the sensor (1) must be replaced.
Repeat the operations leaning the sensor towards
the opposite side.