Electrical Equipment
CHECKING THE HV COIL
•
Remove the left inspection cover, see
(REMOVING THE RIGHT AND LEFT
INSPECTION COVERS).
•
Disconnect terminal (1).
•
Unscrew and remove the two screws (2).
•
Disconnect the spark plug (3).
•
Remove the coil (4).
With a pocket multimeter (scale 200 Ω), measure
•
the resistance (from the coil side) between the
terminals (A e B) indicated in the diagram.
•
If the resistance measured is not correct, replace
the coil.
Standard value: 0.6 Ω Ω Ω Ω Ω ± 0.1 Ω Ω Ω Ω Ω
•
Also verify the resistance between the high
voltage terminal and the casing of the coil.
Standard value: 7.4 kΩ Ω Ω Ω Ω
CAUTION
Before measuring, remove the H.V. cable complete
with the spark plug cap.
6-10
Release 00
2002-09
4
2
A
chap. 6
Atlantic 500
3
1
B