4.0 Maintenance and Troubleshooting

4.0 Maintenance and Troubleshooting

Recommended Inverter and Battery Care

The MM-AE Series inverter/charger is designed to provide you with
years of trouble-free service. Even though there are no user-service-
able parts, it is recommended that every 6 months you perform the
following maintenance steps to ensure optimum performance and
extend the life of your batteries.
WARNING: Prior to performing these checks, switch
both the AC and DC circuits OFF.
Visually inspect the batteries for cracks, leaks, or swelling –
replace if necessary.
Use baking soda to clean and remove any electrolyte spills or
buildups.
Check and tighten all battery holddown clamps.
Clean and tighten (10 to 12 foot-pounds) all DC terminals
(battery and inverter) and connecting cables.
Check and fi ll battery water levels (Liquid Lead Acid batteries
only).
Check individual battery voltages (replace those that vary
more than 0.3 VDC of each other).
Check all cable runs for signs of chafi ng – replace if necessary.
Check the inverter's cooling vents – clean as necessary.

Resetting the Inverter

Under some fault conditions (i.e., an internal fault), the inverter will
need to be reset.
To reset the inverter:
1.
Press and hold the Power ON/OFF pushbutton for approximately
15 seconds, or until the status LED comes on and fl ashes rapidly
(see Figure 2, Items 1 and 2).
2.
Release the Power ON/OFF pushbutton once the rapid fl ashing
has begun. The status LED will go off.
3.
Press the Power ON/OFF pushbutton again to turn the
inverter on.
Info: The Power ON/OFF pushbutton is a small momentary
type switch which operates by lightly pressing and
releasing.
32
© 2010 Magnum Energy, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mm1512aeMm1524aeMm 612ae

Table of Contents