Download Print this page

Specifications - Magnum Energy ME2000 Supplement To Onwer's Manual

Advertisement

Supplement to ME and MS Series Operator's Manual
Model: ME2000 Inverter/Charger
Inverter Operation:
Continuous output power: 2000 Watts @ 25
°C
AC Input: 120VAC/60Hz @ 30 Amps Max with a 12.6VDC Input
Peak output current 33.0AAC, 10 sec surge (unregulated)
Output provided with integral protection against overload
DC Input: 10.0-15.5VDC
Continuous input current: 190A @ 12.6VDC
Charger Operation:
Continuous Charger current: 100ADC @ 11-14VDC
AC Input: 120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16 amps of 120VAC)
Power Factor: @ 10% to 100% charge > .95
Engineered and Manufactured in the U.S.A.
Magnum Energy Inc.
1111 80th St S.W. Suite 250
Everett, Wa. 98203
N1-00001
Serial Number
CB1
CB2
CB3
OUTPUT 1
OUTPUT 2
INPUT 30 A
20
20
30
20A output breakers
Figure 2, AC Wiring for the ME2000-20B

Specifications:

Continuous Output Power:
Continuous Input current:
Peak Output Current:
DC Input:
Continuous Charger Current:
AC Input:
Power Factor:
Part Number 64-0015
ME2000-20B AC Wiring
BLACK
AC HOT IN
WHITE
AC NEU IN
GREEN
AC GROUND
AC GROUND (x2)
AC NEU
WHITE w/BLACK
OUT (x2)
BLUE
AC HOT 1 OUT
AC HOT 2 OUT
ORANGE
ME2000 (-20B)
Model
2000 watts @ 25°C
190A @ 12.6VDC
33.0 AAC, 10 sec surge
(unregulated)
10-16 VDC
100ADC @ 11-14VDC
120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16
amps of 120VAC)
>0.95
AC IN
(30A breaker)
MS2000
Inverter Operation
2000 watts @ 25°C
225A @ 12.6VDC
29.0 AAC, 10 sec surge
(unregulated)
10-17 VDC
Charger Operation
100ADC @ 11-14VDC
120VAC/60Hz @ 30 Amps Max
(Charger can use up to 16 amps
of 120VAC)
>0.95
continued
AC
Main
Panel
AC OUT
AC outlets
(20A circuits)
Page 2 of 2

Advertisement

loading

This manual is also suitable for:

Me2000-20bMs2000