Programming
Note: If you need to add a letter to the account code
press the numbers keys repeatedly until the letter
you want appears on the display. See page 32.
Report Type
To choose the report type to send to the ARC select:
Reporting – Alarms – Report Type.
The report types available are: Fast Format, Contact ID.
Fast Format Channels
If you selected Fast Format in Report Type then you can
select Reporting, Alarms, Fast Format Channel to allocate
one of the following events to each of the 8 channels
(defaults in brackets):
Not used
Fire (default Channel 1)
PA (defaulted Channel 2)
Burglar (defaulted Channel 3)
Open/Close (default Channel 4)
Technical Alarm (default Channel 8)
RF Low Battery
RF Supervision
RF Jamming
Mains Fail
Tamper Alarm
Zone Omitted (Channel 5. see note 2)
Open (see note 1)
Close (see note 1)
Notes:1. Open and Close provide the same functions as
Open/Close, but on two separate channels.
2. Zone Omitted - the control unit sends this signal
for five seconds when a user omits a zone.
3. The control unit delays reporting/logging either
mains loss, or exiting Installer Menu with mains loss,
by 15-18 min (chosen randomly). For Scandinavia
the control unit waits at least 60 minutes before
reporting.