Battery Setting2 - Panasonic AJ-SPX900e Operating Instructions Manual

Memory card camera recorder
Hide thumbs Also See for AJ-SPX900e:
Table of Contents

Advertisement

Items/
Adjustable
Data Saved
Range
ENDURA50
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
AUTO
Select auto or manual to set the NEAR END
voltage.
MANUAL
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.
11.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
:
13.1
steps.
:
15.0
– C U F –
ENDURA80
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
AUTO
Select auto or manual to set the NEAR END
voltage.
MANUAL
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.
11.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
:
13.5
steps.
:
15.0
– C U F –
BP-L60/90
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
AUTO
Select auto or manual to set the NEAR END
voltage.
MANUAL
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.
11.0
When MANUAL is selected in the menu
:
above, set the NEAR END voltage in 0.1 V
11.2
steps.
:
15.0
– C U F –
<Note>
The remaining battery capacity for digital batteries is displayed
as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50/
ENDURA50/ENDURA80).
The BATT NEAR END alarm, however, is triggered according to
the setting on the <BATTERY SETTING1> screen, regardless of
the % indication.
118
Remarks

8-6-3 BATTERY SETTING2

Items/
Adjustable
Data Saved
Range
NiCd14
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
NEAR END 11.0
Set the NEAR END voltage in 0.1 V steps.
:
13.6
:
15.0
END
11.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
:
13.2
:
– C U F –
15.0
NiCd13
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
NEAR END 11.0
Set the NEAR END voltage in 0.1 V steps.
:
12.7
:
15.0
END
11.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
:
12.2
:
– C U F –
15.0
NiCd12
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
NEAR END 11.0
Set the NEAR END voltage in 0.1 V steps.
:
11.5
:
15.0
END
11.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
:
11.2
:
– C U F –
15.0
TYPE A
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
FULL
12.0
Set the voltage to display the FULL
indication in 0.1 V steps.
:
15.0
:
17.0
NEAR END 11.0
Set the NEAR END voltage in 0.1 V steps.
:
13.6
:
15.0
END
11.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
:
13.2
:
– C U F –
15.0
TYPE B
Enable selection under BATTERY SELECT.
:Enable selection.
• :Disable selection.
FULL
12.0
Set the voltage to display the FULL
indication in 0.1 V steps.
:
13.5
:
17.0
NEAR END 11.0
Set the NEAR END voltage in 0.1 V steps.
:
11.8
:
15.0
END
11.0
When MANUAL is selected in the menu
:
above, set the END voltage in 0.1 V steps.
11.1
:
– C U F –
15.0
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P2 aj-spx900e