Weil-McLain CGi Series 3 Installation And Maintenance Manual page 69

Gas-fired
Hide thumbs Also See for CGi Series 3:
Table of Contents

Advertisement

CG i
GAS-FIRED
wATER BOILER-
sERIEs 3 -
Boiler Manual
13b
Ratings
LSJ
~I.IDI
.,.. •••II
CERTIFIED,.
c
H
Table
11
Boiler
ratings
Boiler
model
number
(Note
1)
CGi-25
CGi-3
(Note 5)
CGi-4
(Note
5)
CGi-5
CGi-6
CGi-7
CGi-6
Notes
NO TICE
DOE
Net
AHRI
Boiler
DOE
Heating
0
-
2,000 feet
2,000 - 4,500 feet
ratings
water
Seasonal
Vent
size
capacity
altitude
altitude
(Btuh)
content
e1Ticlency
(Btu
h)
(gallons)
(%AFUE)
(Note
21
Input
Output
Input
Output
(Note
3J
(Note5)
(Note4)
(Btuh)
(Btuh)
(Btuh)
(Btuh)
42,000
50,000
42,000
45,000
38,000
37,000
1.5
84.0
3"
51,000
60,000
51,000
60,000
5
1,000
45,000
1.5
85.1
3"
76,000
90,000
76,000
81,000
68,400
66,000
2.
1
85.0
3"
100,000
119,000
100,000
120,000
101,000
87,000
2.7
83.3
3"
140,000
167,000
140,000
150,000
126,000
122,000
3.3
83.3
3"
167,000
200,000
167,000
180,000
150,000
145,000
3.8
83.0
3"
194,000
233,000
194,000
2 10,000
175,000
169,000
4.4
82.7
3"
1
.
Add
"PIN"
for natural
gas
boiler -
"PIL"
for Liquefied
Petroleum (propane) gas
boiler.
2.
Based
on
standard
test procedures prescribed by the United
States
Department of Energy.
3.
Net
AHRI ratings
are
based on
net Installed radiation
of
sufficient quantity for the requirements
of
the
building and nothing
need
be added
for
normal p iping
and pickup. Ratings are
based
on a pip-
ing and
pickup
allowance
of
1.15.
An additional
allowance
should
be
made
for unusual
piping
and
pickup
loads.
4.
CGi boilers
require special venting
,
consistent with
Category
I
or
Ill
boiler. Use
only the vent
materials
and
methods
specified In
this
manual. Vent
diameter
shown
above Is
for
direct
exhaust
venting
. See
Table
3, page 14, for vent d
iameter
when chimney draft venting.
5. As an Energy Star Partner,
Well-Mclain
has detennlned
that
the CGI-3
&
4
meets
the Energy Star guidelines for
energy efficiency.
CGi boilers for
residential radiant panel
systems, converted gravity heating
systems
or other low water
tempera-
ture applications
should
be installed with balancing valves and bypass piping equal to the
supply
and
return
size
to
avoid excessive
flue
gas
condensation
due
to lower operating water
temperatures.
For
alternate piping,
contact your Weil-McLain sales office. CSA
design
certified for
installation
on combustible
flooring.
Tested
for
50 psi working
pressure.
Part Number
550-142-780/0712
69