CG i
GAS-FIRED wATER BOILER- sERIEs a -
Boiler Manual
2a
12
Prepare boiler - placement & setup
Place boiler/crate near
position
t.
Leave boiler in crate and on pallet
until
installatio
n
site
is ready.
2. Move entire crate and pallet next to selected location.
3.
Remove
crate.
4.
Remove
boiler
from
pallet
NOTICE
I
Do
not
drop
boiler
or bmnp
jacket
on
.
floor or pallet
Damage
to boiler can
result
a. Tilt left side of boiler
up
and place a
board under
left legs.
b.
Tilt boiler the other way and
place
a board under
right legs.
c. Slide boiler backward
off
pallet
and
into
position
.
5. Check level.
a.
Shim
legs,
if
necessary.
b. Do
not
alter
legs.
Inspect orifices and burners
t.
Remove front
jacket door.
Remove
burner shield (see
Figure
40,
item
4, page 60).
2.
Check
forcorrectly-sized manifold orifices.
See
Table 2
for sizing.
(The orifice
size is stan1ped
o
n
the orifice
spud barrel.)
Correctly-sized manifold
orifices
must
be
used.
Failure
to do
so will
result in
severe
personal injury,
death or
sub-
stantial property
damage.
3.
Reinstall burner
shield.
I&
WARNING!
Do
no
t
operate
boiler
without
burner shield
in place.
Failure
to
do so could result
in
severe
personal
injury, death or
sub-
stantial property
damage.
Orifice replacement
procedure
(when
required)
t.
Remove the
screws securing
the burner
shield
and remove
burner shield.
2.
Using
a
'h<''
open-end
wrench,
rem
ove the
burner
orifices
from
the manifold.
3. Apply
a
small amount of
pipe dope to
each
of
t11e new
orifices and
install
in
t11e
manifold
us-
ing
a
'I..''
open-end
wrench.JV!akesure the
ori-
fices
are aligned
correctly,
not
cross-threaded
in the
manifold tappings.
I&
WARNING!
Use only pipe
dope
compatible
with propane gas, even
if
boiler
is to
be operated o
n
natural
gas. Failure to comply could
result in severe personal
injury,
death
or substantial property
damage.
4. Carefully replace the burner shield.
5.
Follow the check-o
ut
procedure,
Section
8
page 36,
to
assure
the boiler
is
now
operating
properly
after
orifices
are
replaced.
Table 2
Manifold orifice
sizing at sea
level
and
a~ltudes
to 4,500
feet
Location
Boiler model
Natural gas
Propane gas
number
0-2,000
over 2,000
H.
0-2,000
over 2,000
ft.
CGi-25
2.30mm
#54
u.s.
CGi-3
and
CGi-5
2.55mm
(Note 1)
1.60mm
(Note 1)
CGi-4, CGi-6 -
CGi-8
2.70mm
1.65mm
0-2,000
2,000-4,500
0-2,000
2,000-4,500
Canada
CGi-25
2.30mm
#44
#54
#55
CGi-3
and
CGi-5
2.55mm
#41
1.60mm
1.45
mm
CGi-4, CGi-6 -
CGi-8
2.70mm
#38
1.65mm
#53
Note
1:
For
elevations
above 2,000
leet,
contact your local Weii·Mclain
sales office
lor
details.
Part
Number 550-142-780/0712