Weil-McLain CGi Series 3 Installation And Maintenance Manual page 54

Gas-fired
Hide thumbs Also See for CGi Series 3:
Table of Contents

Advertisement

CG i
GAS-
FI
RED wATER
eo1LER-
sERIEs
a-
Boiler Manual
llc
Troubleshooting - control module lights
CHART 1 -
Troubleshooting
POWER
light
statu
s
-
Usually
indicates
reversed 120 VAC polarity if POWER
light flashes
by itself
-
IAWARNINGI
Electrical shock
hazard
-
Wherever
you
see
.t.
TURN
OFF
POWER
&
,
follow the
instructions.
Failure
to
follow
·
·
instructions
could
result
in
severe
personal
injury, death
or substantial
property
damage.
Is
POWER
light
off?
Make
sure
service
swttch
or
circutt
breaker is
on
or
No
Yes
fuses are
good.
Remove 120 VAC
IN
plug
(Figure
38, Item
3,
page 53)
on
control
module.
Using
voHmeter,
check across
black
and white
wire pins
Is
POWER
light
...
of
120 VAC
IN
plug.
Flashing
Flashing
wtth
On
steady
Does
voltmeter indicate
120 VA
C?
alone
another
light
(not
flashing)
1-
No
Yes
TSTAT
CIRC
Chart
Problem
is with
incoming
light
flashing
2
electricity. Have licensed
PURGE
Chart
Chart
electrician
repair
circutt.
light
flashing
3
5
FLAME
Chart
Chart
Reconnect
120 VAC IN
plug.
light
flashing
4
6
Remove
transformer
plug
(Figure
38,
Item
2,
page
53)
For
insufficient
heat or no heat problem,
go
to
on
control
module.
Chart
7
if
POWER
light is on
steady,
wtth
no
other
1+-
Using
voHmeter,
check across
left
side top and
bottom
light
flashing.
pins
of transformer
receptacle.
Does
voltmeter indicate
120 VA
C?
No
Yes
~
Usually indicates polarity on
incoming
120 VAC
power
Replace
control
module.
line
is wrong.
Retest.
• .t.
TURN
OFF POWER
.t.
at
service switch
or
breaker,
then
reverse
the HOT and
NEUTRAL
wires
entering
the
boiler
in
the J-box.
Reinstall
120
VAC
transformer
plug.
Restore
POWER
at
service swttch
or
breaker.
Remove
T
STAT
transformer
plug
(Figure
38,
Item 5,
Is
POWER
light flashing now?
page
53)
on control module.
No
Yes
Using
voHmeter,
check pins
of plug
.
Does voltmeter indicate
24
VAC?
No
Yes
Have
system checked by
a
+
licensed
electrician.
If
Replace transformer.
problem
persists,
call
your
Retest
and
check
for
back
Boiler
should now
I
local
Weii-Mclain sales
feed of voltage from
Replace
control module.
operate normally.
representative.
system
wiring.
Retest.
54