19. Miscellaneous Errors
19.2 Fatal error engine I/F
Print Control Board (PWB-P)
Step
Turn OFF the Power Switch, wait for 10 sec. or
1
3
more, and turn ON the Power Switch.
Check the USB cable for proper connection and
2
correct as necessary.
Check the PWB-P connector for proper connec-
3
tion and correct as necessary.
Check the PWB-A connector for proper connec-
4
tion and correct as necessary.
5
Change PWB-P.
6
Change PWB-A.
19.3 ROM error
Print Control Board (PWB-P)
Step
Turn OFF the Power Switch, wait for 10 sec. or
1
3
more, and turn ON the Power Switch.
Check the PWB-P connector for proper connec-
2
tion and correct as necessary.
3
Change PWB-P.
144
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
Relevant Electrical Parts
Action
Field Service Ver. 4.0 Feb. 2006
WIRING DIAGRAM
Control Signal
(Electrical
Component)
-
-
-
-
-
-
WIRING DIAGRAM
Control Signal
(Electrical
Component)
-
-
-
Location
-
-
-
-
-
-
Location
-
-
-