Field Service Ver. 4.0 Feb. 2006
19.8 Fatal error AIDC Sensor
AIDC Sensor (AIDC)
Step
Turn OFF the Power Switch, wait for 10 sec. or
1
3
more, and turn ON the Power Switch.
Check the AIDC connector for proper connection
2
and correct as necessary.
Check the PWB-A connector for proper connec-
3
tion and correct as necessary.
4
AIDC sensor check.
5
Change AIDC.
6
Change PWB-A.
19.9 Controller internal error
Print Control Board (PWB-P)
Step
Check the PWB-P connector for proper connec-
1
tion and correct as necessary.
2
Change PWB-P.
19.10 Fatal error DBE
Print Control Board (PWB-P)
Step
Turn OFF the Power Switch, wait for 10 sec. or
1
3
more, and turn ON the Power Switch.
Check the PWB-P connector for proper connec-
2
tion and correct as necessary.
3
Change PWB-P.
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
19. Miscellaneous Errors
WIRING DIAGRAM
Control Signal
(Electrical
Component)
-
-
-
-
-
WIRING DIAGRAM
Control Signal
(Electrical
Component)
-
-
WIRING DIAGRAM
Control Signal
(Electrical
Component)
-
-
-
Location
-
-
-
-
-
Location
-
-
Location
-
-
-
147